Trouble installing an aztrax DT2-2W detection system and relay to automate a reversing loop

890 views
4 replies
1 rating 2 rating 3 rating 4 rating 5 rating
  • Member since
    March 2023
  • 1 posts
Trouble installing an aztrax DT2-2W detection system and relay to automate a reversing loop
Posted by Ricks NC layout on Monday, March 20, 2023 5:21 PM

The Azatrax DT2-2W system will detect trains (IR) in a reverasing loop and automatically change a turnout and swap polarity of the mainline thru a DPDT relay.

I have the detection and turnout operation working but every time it turns on the DPDT relay the mainline shorts out. Help?

  • Member since
    March 2011
  • From: Westford MA
  • 471 posts
Posted by Tophias on Tuesday, March 21, 2023 10:55 AM

Rick, I have no experience with this product, but in the interest of taking a shot before people who actually know what they're talking about chime in, might I suggest swapping the wire that come out of the board to feed the power to the loop.  If that fails, try reversing the input wires. If that fails, wait for knowledgeable people to respond.

Regards, Chris 

  • Member since
    September 2004
  • From: Dearborn Station
  • 24,076 posts
Posted by richhotrain on Tuesday, March 21, 2023 11:12 AM

The whole point of an automated reversing section is to match the polarity inside the reversing section with the polarities of the adjacent non-reversing sections.

You indicate that the mainline shorts out. Presumably, the mainline is the non-reversing section, so it should not be shorting out.

Have you gapped the rails to isolate the reversing section from the mainline?

Rich

Alton Junction

  • Member since
    April 2004
  • From: Ontario Canada
  • 3,571 posts
Posted by Mark R. on Tuesday, March 21, 2023 11:24 AM

If the DPDT relay is supposed to change the polarity of the entire main line, there cannot be ANY power feeds to the mainline aside from the two coming from the DPDT relay.  If there is, the relay will send opposite polarity to the main and short the other leads that are wired directly to the main.

If you are running DCC, that DPDT relay should be changing the polarity in the loop, not the main. Changing "polarity" in DCC does not affect the direction the train is moving.

Mark.

¡ uʍop ǝpısdn sı ǝɹnʇɐuƃıs ʎɯ 'dlǝɥ

  • Member since
    September 2014
  • From: 10,430’ (3,179 m)
  • 2,281 posts
Posted by jjdamnit on Tuesday, March 21, 2023 1:14 PM

Hello All,

Have you contacted Azatrax?

Hope this helps.

"Uhh...I didn’t know it was 'impossible' I just made it work...sorry"

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!