Trains.com

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Can't Reset Loksound V5 Decoder.

9113 views
40 replies
1 rating 2 rating 3 rating 4 rating 5 rating
  • Member since
    July 2006
  • From: Bradford, Ontario
  • 15,797 posts
Posted by hon30critter on Thursday, June 23, 2022 12:07 AM

BATMAN
FIXED!!!!!!

I am happy to hear that Brent.

DCC can be very unforgiving. Several years ago one of my critters was acting up so I did a factory reset. After that the decoder seemed to be totally dead. I tried all sorts of things programming wise but nothing worked, so I decided the decoder was faulty.

To make a long story short, the problem was simply that I was inputting address 03 incorrectly on my NCE PowerCab. I was putting in address "003" instead of "03". The display shows the address as '003' when it is actually '03', so I was simply putting in the address that the display showed.

Fortunately a fellow forum member pointed out the error of my ways, but unfortunately I had already removed the decoder and in the process I managed to destroy part of the shell. I still haven't fixed it.

Dave

I'm just a dude with a bad back having a lot of fun with model trains, and finally building a layout!

  • Member since
    September 2004
  • From: Dearborn Station
  • 24,281 posts
Posted by richhotrain on Thursday, June 23, 2022 6:34 AM

I have been following this thread, but I have offered no replies because I had no answers. But now that Brent has solved the problem, I will offer these comments.

I also have the NCE Power Pro 5 amp wireless system. I use the Advanced Consist option quite often because I run my passenger train locomotives in AA and AB consists. I also run diesel freight locomotives in consists. I never use Old Style Consists.

That said, there have been occasions where I clear a consist and CV19 is not cleared even though I follow the NCE instructions for clearing consists. In fact, it happens often enough that when a locomotive has lights and sound but no movement, CV19 is the problem.

I no longer waste time putting the locomotive on the Programming Track to check CV19 to see if that is the problem. I simply use the Ops mode on the mainline to set CV19 to zero, and that solves the problem.

I blame all of this on the NCE command station. I don't know why CV19 is not reset to zero, but it often not reset to zero.

I have never documented the problem and the solution in writing to remind myself of this recurring issue, but I'll bet if I went down to my layout right now, this very problem will occur on at least one consist.

Rich

Alton Junction

  • Member since
    May 2020
  • 1,057 posts
Posted by wrench567 on Thursday, June 23, 2022 8:06 AM

  Rich.

  The same with my Power Cab system. Weather it's user error ( probably), or the offending locomotive had a disconnect from dirty wheels or track. It happens. On the clubs Lenz system I would old fashion consist two advanced consist sets and sometimes have difficulty breaking them up. Or one locomotive never got the message. I then found it easier just to use two throttles for the pusher section. But an extra throttle was not always available.

     Pete.

  • Member since
    September 2004
  • From: Dearborn Station
  • 24,281 posts
Posted by richhotrain on Thursday, June 23, 2022 8:17 AM

wrench567

  Rich.

  The same with my Power Cab system. Weather it's user error ( probably), or the offending locomotive had a disconnect from dirty wheels or track. It happens. 

Good points, Pete. 

I would rule out dirty wheels and dirty track because I have checked that out on my layout. It still could be, but that is not my experience.

As to user error, I cannot claim to be infallible as an operator. But, in this case, I will rule out operator error because, over time, I feel that I have developed sufficient expertise with Advanced Consisting to do it right.

My conclusion is that there is some type of flaw in the NCE system, either the command station or the wireless throttle. I have often wondered if the CV19 error could be eliminated by using a tethered throttle. In other words, I consider the wireless system as a "throttle of interest".

Rich

Alton Junction

  • Member since
    February 2002
  • From: Mpls/St.Paul
  • 13,892 posts
Posted by wjstix on Thursday, June 23, 2022 9:52 AM

wrench567

 . Stixx hit on it about ten posts ago. Old fashioned consist!!!!! There was nothing wrong with the decoder at all. The consist is held in the command station. As long as the locomotive is on the track it will only be controlled by the consist address.

    Pete.

 
A lot of time, complicated problems turn out to be easy to fix, it's the simple ones that cause problems! I've done that, tried to run an engine and found it didn't work or ran hesitatingly, only to (eventually) realize it was a trailing engine in a consist.
 
I had an engine once that I couldn't get to do anything, no sound, no lights, etc. Tried a lot of settings, even opened it up to check on the decoder. Could see nothing wrong, and it ran fine on DC when I tested it.
 
Finally put it on the programming track and read back the ID. Oops! Apparently I had changed the ID without knowing it. (I think I tried to like change CV 110 to "1", but instead somehow changed CV1 to "110", changing the ID to 110.) Dunce
Stix
  • Member since
    May 2020
  • 1,057 posts
Posted by wrench567 on Thursday, June 23, 2022 11:13 AM

   Rich.

 There could be an issue with the wireless throttle. But the same thing happens with the wired Power Cab. Because of computers, things that would take days to screw up now only takes seconds. When the Power Cab was version 1.1. I never noticed any problems. After the upgrade chip to version 1.6 when I exit program track for some reason the bell is on F4. I have to unplug the tether and restart the cab. Then everything is normal. Strange behavior indeed.

    Stix.

  You don't have to tell me about bonehead moves. I'm a master at it. One of my steamers wouldn't run. Instead of address 9827, I was putting in 8927. The font at quick glance the 9 looks like an 8 and vice a verse. Note to self. Put on glasses before operating!!!!

   Been there done that. Will be across my headstone.

     Pete.

  • Member since
    September 2004
  • From: Dearborn Station
  • 24,281 posts
Posted by richhotrain on Friday, June 24, 2022 6:37 AM

wrench567

   Rich.

 There could be an issue with the wireless throttle. But the same thing happens with the wired Power Cab. Because of computers, things that would take days to screw up now only takes seconds. When the Power Cab was version 1.1. I never noticed any problems. After the upgrade chip to version 1.6 when I exit program track for some reason the bell is on F4. I have to unplug the tether and restart the cab. Then everything is normal. Strange behavior indeed.

The next time this happens to me, I will write down what actually occurred and what steps I took to solve the problem. I will also document the decoder(s) involved. I do have lots of consists with QSI Quantum decoders, so if it is not the NCE system causing the problem, the decoder(s) then become suspect.

Rich

Alton Junction

  • Member since
    July 2006
  • From: 4610 Metre's North of the Fortyninth on the left coast of Canada
  • 9,352 posts
Posted by BATMAN on Saturday, June 25, 2022 10:16 AM

hon30critter

 

 
BATMAN
FIXED!!!!!!

 

I am happy to hear that Brent.

DCC can be very unforgiving. Several years ago one of my critters was acting up so I did a factory reset. After that the decoder seemed to be totally dead. I tried all sorts of things programming wise but nothing worked, so I decided the decoder was faulty.

To make a long story short, the problem was simply that I was inputting address 03 incorrectly on my NCE PowerCab. I was putting in address "003" instead of "03". The display shows the address as '003' when it is actually '03', so I was simply putting in the address that the display showed.

Fortunately a fellow forum member pointed out the error of my ways, but unfortunately I had already removed the decoder and in the process I managed to destroy part of the shell. I still haven't fixed it.

Dave

 

Dave, In my endless reading trying to resolve the problem, the conflicting advice on how many "0" to add when programing a CV was enough to drive you nuts, especially CV 8.

This little exercise in frustration has taught me a few things at least and that is never a bad thing. I came across a guy with the same problem on FB and suggested the delete from consist button and he was up and running again in no time.

I have two Rapido FP7As and one "B" unit and they have been in and out of consist a lot. I will hit the delete from consist button for all of them just to be sure. I haven't tried it yet, but I wonder if I will still get the "can not read" notice on the programming track for the "B" unit?

I was seeking help on the ESU forum and those guys sure like to make you feel stupid, not here though, it is a better fit for me. Thanks for all your help.

Brent

"All of the world's problems are the result of the difference between how we think and how the world works."

  • Member since
    May 2020
  • 1,057 posts
Posted by wrench567 on Saturday, June 25, 2022 12:45 PM

  Brent.

  We have all been there. Especially when DCC was in it's infancy. I couldn't tell you how many decoders I have had to reset because of a simple problem that with a little deductive reasoning could have saved the day. I have had decoders get scrambled when someone else shorted the track. And when someone broadcast program instead of POM. Before disabling DC in CV29 would rocket your train across the layout. Flashing lights, melted shells, and buzzing motors were all part of the learning curve.

    When something weird happens. The first thing that goes through my head is. What was the last thing I did before it messed up? Then work back from there.

       Like the Pink Floyd song. Welcome to the machine.

      Pete.

  • Member since
    February 2020
  • 31 posts
Posted by know2go on Saturday, July 30, 2022 3:16 PM

Hi Batman, when you get "cannot read CVs when on the programming track, usually this is the decoder issue. replacing the decoder with a new one usually fixes this and by extension, other problems.

  • Member since
    July 2006
  • From: 4610 Metre's North of the Fortyninth on the left coast of Canada
  • 9,352 posts
Posted by BATMAN on Saturday, July 30, 2022 3:20 PM

know2go

Hi Batman, when you get "cannot read CVs when on the programming track, usually this is the decoder issue. replacing the decoder with a new one usually fixes this and by extension, other problems.

 

I sent it back to Rapido and they said it was definitely a bad decoder and it is currently on its way back across the country homeward bound.Big Smile

Brent

"All of the world's problems are the result of the difference between how we think and how the world works."

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!