Posted by RideOnRoad on Monday, August 18, 2014 3:58 PM

I have a very basic DC loop layout that looks like the following:

Loop

There is power on both sides of the loop, but am currently using the turnout to route power to the spur. I have insulated the main loop on the outbound sides of the turnouts (represented by the isolators on the drawing.) I have two questions.

  1. If I replace the DC connection to the layout with a DCC connection, as is, will it continue work?
  2. If I want to add power directly to the siding, do I need to isolate the spur also?

I am really a novice when it comes to all things electronic.

Richard

  • Member since
    September 2004
  • From: Dearborn Station
  • 24,281 posts
Posted by richhotrain on Monday, August 18, 2014 4:19 PM

If these turnouts are Peco Electrofrogs, then the two inner rails (the frog rails) beyond the frog should be gapped to prevent shorts in DCC mode. On the divergent side of the turnout, it then becomes your choice to power or not power the spur.  In DCC, it makes sense to power the spur.

Rich

Alton Junction

  • Member since
    February 2004
  • From: Central Ohio
  • 570 posts
Posted by basementdweller on Monday, August 18, 2014 5:15 PM

am I right to assume that currently using DC you have only one connection from the power pack / transformer? If so with DCC you will want multiple feeders supplying power to multiple points around the oval thus eliminating the Power routing ability as current will be feeding both ends of the turnout. You can still have the ability to control current to the diverting route but some may suggest to add feeders to the sidings too.

why the need for multiple feeders? DCC works best with a strong signal to all points of the layout, it's more than voltage drop like DC. 

In my opinion power routing turnouts on DCC layout are ok but really become unnecessary as each locomotive is independantly controlled so no need to turn the track on and off like DC. Hope this helps.

  • Member since
    December 2012
  • From: Mesa, AZ
  • 1,530 posts
Posted by RideOnRoad on Monday, August 18, 2014 5:41 PM

basementdweller

am I right to assume that currently using DC you have only one connection from the power pack / transformer?

No, I have two feeders, one on each side of the track. The loop is small so the distance between the two feeders is approximately six feet of track. (It's an N-scale layout.) All connections are soldered. I plan on adding feeders to the sidings after the cutover to DCC.

Richard

  • Member since
    July 2003
  • From: Sierra Vista, Arizona
  • 13,757 posts
Posted by cacole on Tuesday, August 19, 2014 9:06 AM

If everything is working properly on DC, it will work properly on DCC with no changes necessary.

  • Member since
    February 2007
  • From: Christiana, TN
  • 2,134 posts
Posted by CSX Robert on Tuesday, August 19, 2014 4:13 PM

RideOnRoad
...
  1. If I replace the DC connection to the layout with a DCC connection, as is, will it continue work?

...

Yes.

 

RideOnRoad
...

      2.  If I want to add power directly to the siding, do I need to isolate the spur also?

...

 

Yes.

  • Member since
    September 2004
  • From: Dearborn Station
  • 24,281 posts
Posted by richhotrain on Tuesday, August 19, 2014 5:59 PM

CSX Robert
RideOnRoad
...

      2.  If I want to add power directly to the siding, do I need to isolate the spur also?

...

 

 

 

Yes.

 

If you power the spur in DCC, it won't hurt anything if you completely isolate the spur.

But it would be sufficient to gap the inner rail, that is, the divergent frog rail.

Rich

Alton Junction

  • Member since
    December 2012
  • From: Mesa, AZ
  • 1,530 posts
Posted by RideOnRoad on Tuesday, August 19, 2014 9:24 PM

If I gap both inner rails from the turnout, does that men that the frog is now longer powered?

Richard

  • Member since
    January 2010
  • From: Chi-Town
  • 7,712 posts
Posted by zstripe on Tuesday, August 19, 2014 10:39 PM

Richard,

The frog will still be powered....the polarity of it will be determined upon which point is touching which stock rail, that would be power routing from the points. The straight route and the diverging route will have to have feeders added after the insulated joiners.

This site will explain with diagrams how to do that and also more reliable ways. Take some time out and go over it to better familiarize yourself with all the wiring techniques and tips. Great site to have for future reference:

http://www.wiringfordcc.com/switches.htm

Take Care!

Frank

  • Member since
    September 2004
  • From: Dearborn Station
  • 24,281 posts
Posted by richhotrain on Wednesday, August 20, 2014 3:22 PM

RideOnRoad

If I gap both inner rails from the turnout, does that mean that the frog is no longer powered?

 

Actually, the frog isn't powered directly unless you add feeders to the frog.

Out of the box, on a Peco Electrofrog, the metal frog is not isolated from the closure rails or the frog rails.  So, the frog picks up power from the closure rails and the frog rails.  But, once you gap the frog rails (i.e., the inner rails), the only source of power to the frog is from the closure rails. In turn, the closure rails are connected, via hinges, to the point rails.  

Since the Peco Electrofrog is designed to operate as a power routing turnout, the point rails will be thrown against either the through stock rail or the divergent stock rail, picking up the polarity of the respective stock rail. So, with the frog rails gapped, power is routed to the frog from the stock rail, via the point rail, via the closure rail.  At that point, polarity of the frog is determined by the polarity of the stock rail against which the point rail is thrown.

Rich

 

Alton Junction

  • Member since
    September 2004
  • From: Dearborn Station
  • 24,281 posts
Posted by richhotrain on Thursday, August 21, 2014 5:50 AM

One further thought on powering the frog on a Peco Electrofrog turnout.

You could gap not only the frog rails but also the closure rails completely isolating the frog.

Now you have a dead metal frog.  There are many ways to power the isolated metal frog.

Here is an example.

http://www.teamdigital1.com/applications/tech_talk/frog_power.html

Rich

Alton Junction

  • Member since
    February 2002
  • From: Reading, PA
  • 30,002 posts
Posted by rrinker on Thursday, August 21, 2014 8:28 AM

 Electrofrogs already have the rail gapped. The frog can be completely isolated by snipping the jumpers underneath.

Scroll down to the Electrofrog section, 12-b: http://www.wiringfordcc.com/switches_peco.htm

 

           --Randy

 


Modeling the Reading Railroad in the 1950's

 

Visit my web site at www.readingeastpenn.com for construction updates, DCC Info, and more.

  • Member since
    September 2004
  • From: Dearborn Station
  • 24,281 posts
Posted by richhotrain on Thursday, August 21, 2014 9:12 AM

rrinker

 Electrofrogs already have the rail gapped. The frog can be completely isolated by snipping the jumpers underneath.

 

The closure rails are not gapped, they are what I would term "gap ready".  

To gap them, you have to cut the jumpers.

Rich

Alton Junction

  • Member since
    December 2012
  • From: Mesa, AZ
  • 1,530 posts
Posted by RideOnRoad on Thursday, August 21, 2014 9:57 AM

zstripe

. . .This site will explain with diagrams how to do that and also more reliable ways. Take some time out and go over it to better familiarize yourself with all the wiring techniques and tips. Great site to have for future reference:

http://www.wiringfordcc.com/switches.htm . . .

Frank,

Thanks for for the pointer! I just gave the section on the Electrofrogs a quick read and realized it is going to take a while to digest. (Remember, electronics novice.) I am going to buy a new turnout that I can play with, one that is not attached to my layout, and try to learn.

Richard

  • Member since
    September 2004
  • From: Dearborn Station
  • 24,281 posts
Posted by richhotrain on Thursday, August 21, 2014 10:23 AM

RideOnRoad

 

 
zstripe

. . .This site will explain with diagrams how to do that and also more reliable ways. Take some time out and go over it to better familiarize yourself with all the wiring techniques and tips. Great site to have for future reference:

http://www.wiringfordcc.com/switches.htm . . .

 

 

Frank,

Thanks for for the pointer! I just gave the section on the Electrofrogs a quick read and realized it is going to take a while to digest. (Remember, electronics novice.) I am going to buy a new turnout that I can play with, one that is not attached to my layout, and try to learn.

 

While Alan's web site is excellent, it is very technical and very difficult for a novice to fully grasp.

Here is another excellent web site with much easier to understand photos. 

 http://railwaybobsmodulebuildingtips.blogspot.com/2011/06/insulfrog-or-electrofrog-that-is.html

http://railwaybobsmodulebuildingtips.blogspot.ca/2013/01/the-peco-electrofrog-circuitry.html

If you purchase a spare Electrofrog to play with and to analyze its construction and operation, do some electrical continuity tests on it as well to get a sense of how it is all put together.

Rich

Alton Junction

  • Member since
    December 2011
  • From: Northern Minnesota
  • 2,774 posts
Posted by NP2626 on Thursday, August 21, 2014 11:29 AM

RideOnRoad

I have a very basic DC loop layout that looks like the following:

Loop

There is power on both sides of the loop, but am currently using the turnout to route power to the spur. I have insulated the main loop on the outbound sides of the turnouts (represented by the isolators on the drawing.) I have two questions.

  1. If I replace the DC connection to the layout with a DCC connection, as is, will it continue work?
  2. If I want to add power directly to the siding, do I need to isolate the spur also?

I am really a novice when it comes to all things electronic.

 

I used almost all Atlas Custom Line switches with one Shinohara sissors crossover on my layout with some power routing via Atlas Solinoids.  My frogs are also powered with Atlas Solinoids.  My layout had been designed with DC block control.  Other than wiring my Digitrax Zephyr as one of the throttles, no other changes; or, upgrades where made to allow use of DCC.  This system has worked flawlessly for 10 years.

NP 2626 "Northern Pacific, really terrific"

Northern Pacific Railway Historical Association:  http://www.nprha.org/

  • Member since
    February 2002
  • From: Reading, PA
  • 30,002 posts
Posted by rrinker on Thursday, August 21, 2014 12:48 PM

 OK, I have to say, what makes that site less complicated than Alan's? It's exactly the same, drawing the circuit paths with red and blue lines!

 The jumper cuts are actually also on the instruction sheet included with the Electrofrogs (at least the Code 83 ones I bought).

                   --Randy


Modeling the Reading Railroad in the 1950's

 

Visit my web site at www.readingeastpenn.com for construction updates, DCC Info, and more.

  • Member since
    September 2004
  • From: Dearborn Station
  • 24,281 posts
Posted by richhotrain on Thursday, August 21, 2014 1:22 PM

rrinker

OK, I have to say, what makes that site less complicated than Alan's? It's exactly the same, drawing the circuit paths with red and blue lines!

 

My point was that Alan's web site is excellent, but it is very technical and very difficult for a novice to fully grasp, whereas Bob's web site includes easier to understand photos - - - in my opinion. 

Here are the turnout drawings on the two web sites.  I will leave it to the other interested forum members to decide for themselves if one is easier to understand than the other.  If not, so be it.

Rich

Alton Junction

  • Member since
    January 2010
  • From: Chi-Town
  • 7,712 posts
Posted by zstripe on Saturday, August 23, 2014 6:05 AM

RideOnRoad

 

 
zstripe

. . .This site will explain with diagrams how to do that and also more reliable ways. Take some time out and go over it to better familiarize yourself with all the wiring techniques and tips. Great site to have for future reference:

http://www.wiringfordcc.com/switches.htm . . .

 

 

Frank,

Thanks for for the pointer! I just gave the section on the Electrofrogs a quick read and realized it is going to take a while to digest. (Remember, electronics novice.) I am going to buy a new turnout that I can play with, one that is not attached to my layout, and try to learn.

 

Richard,

You are quite..welcome. Just a point to remember,, You can have all the diagrams and instructions showing whats going on....but without reading the text and comprehending the why's of what's going on.....the diagram's/instructions, are useless.

When using an Electrofrog turnout and only insulating the two inner rails after the frog and using the points for power routing through the frog, you run the risk of the wheel flange and tire bridging the gap between the point and the stock rail, which will be the opposite polarity and creating a short. That is one reason why it is a good idea to isolate the frog entirely and power it separately....which would be my choice. I run a DC layout and have been wiring switches for years and the way mine is wired any DCC system will work fine on it.

Take Care! Big Smile

Frank

  • Member since
    September 2004
  • From: Dearborn Station
  • 24,281 posts
Posted by richhotrain on Saturday, August 23, 2014 7:18 AM

zstripe

  

RideOnRoad

 zstripe

. . .This site will explain with diagrams how to do that and also more reliable ways. Take some time out and go over it to better familiarize yourself with all the wiring techniques and tips. Great site to have for future reference:

http://www.wiringfordcc.com/switches.htm . . .

 

Frank,

Thanks for for the pointer! I just gave the section on the Electrofrogs a quick read and realized it is going to take a while to digest. (Remember, electronics novice.) I am going to buy a new turnout that I can play with, one that is not attached to my layout, and try to learn.

 

You are quite..welcome. Just a point to remember,, You can have all the diagrams and instructions showing whats going on....but without reading the text and comprehending the why's of what's going on.....the diagram's/instructions, are useless.

When using an Electrofrog turnout and only insulating the two inner rails after the frog and using the points for power routing through the frog, you run the risk of the wheel flange and tire bridging the gap between the point and the stock rail, which will be the opposite polarity and creating a short. That is one reason why it is a good idea to isolate the frog entirely and power it separately....which would be my choice. I run a DC layout and have been wiring switches for years and the way mine is wired any DCC system will work fine on it.

Take Care! 

Frank

 

The decision to acquire a spare Electrofrog turnout and experiment with it is a good one.  I have done this myself, not only with turnouts but other electrical components as well. It is true that no amount of diagrams, or text for that matter, can replace hands on testing to gain experience.

The idea of completely isolating the frog and powering it separately is a good one as well.  Now, you have the best of both worlds, power routing and a live frog, without the risk of shorts.  Both Alan's web site and Bob's web site, as previously discussed, describe the procedures necessary to completely isolate the frog on a Peco Electofrog.

Incidentally, the risk of the wheel flange bridging the gap between the point rail and the stock rail and causing a momentary short exists on a Peco Electrofrog out of the box whether or not the inner frog rails are gapped.  Completely isolating the frog will remove this potential momentary short issue.

Rich

Alton Junction

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!