Trains.com

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Shorts in new track

7101 views
38 replies
1 rating 2 rating 3 rating 4 rating 5 rating
  • Member since
    July 2006
  • From: North Dakota
  • 9,592 posts
Posted by BroadwayLion on Friday, February 28, 2014 7:13 AM

You have checked each and every feeder to be sure that they are connected correctly.

You have physically run your finger along the right rail, and never once found yourself on the left rail indicating an unsuspected reversing loop or wye.

You did NOT use a latex caulk to hold tracks in place, since this will conduct electricy when wet, and will never dry under the tracks where never exposed to air.

Your ballast and the glue used therein is not causing a short.

ROAR

The Route of the Broadway Lion The Largest Subway Layout in North Dakota.

Here there be cats.                                LIONS with CAMERAS

  • Member since
    December 2011
  • 156 posts
Posted by Moses45 on Friday, February 28, 2014 8:05 AM

RICHHOTRAIN is helping me out with this problem. With his systematic approach I discovered miswirng to the BUS. He identified a revers loop and is educating this oldtimer. This is a layout I designed myself without any knowledge of electricity.

  • Member since
    September 2004
  • From: Dearborn Station
  • 24,281 posts
Posted by richhotrain on Friday, February 28, 2014 9:06 AM

Here is the OP's track plan.  He emailed it to me to post for him.

This track plan is an addition to his existing layout and begins on the upper left side of the diagram with those two tracks runnning down the left side of the addition.

Rich

 

Alton Junction

  • Member since
    February 2002
  • From: Reading, PA
  • 30,002 posts
Posted by rrinker on Friday, February 28, 2014 10:14 AM

There's a reverse loop there if you come down the right side track at the left and follow it around, you can come back out the middle track going the opposite way. That's why there's a short.

              --Randy

 


Modeling the Reading Railroad in the 1950's

 

Visit my web site at www.readingeastpenn.com for construction updates, DCC Info, and more.

  • Member since
    September 2004
  • From: Dearborn Station
  • 24,281 posts
Posted by richhotrain on Friday, February 28, 2014 10:28 AM

rrinker

There's a reverse loop there if you come down the right side track at the left and follow it around, you can come back out the middle track going the opposite way. That's why there's a short.

              --Randy

 

 

BINGO !

You gotta love track diagrams.  A picture speaks a thousand words.

Rich

Alton Junction

  • Member since
    July 2006
  • From: North Dakota
  • 9,592 posts
Posted by BroadwayLion on Friday, February 28, 2014 10:30 AM

 

There is a reversing loop. Install gaps as shown at both ends of the middle track.

Let switch A control the power to the middle track.

Let the normal positon of switch A be against the middle track

Let the reverse position of switch A be aligned for the middle track.

When Switch A is reversed power crosses to the middle track from the tracks outside of switch A

When Switch A in in the normal position, power comes to the middle track from the other end.

Trains must stop on the middle track before proceeding, and Switch A must be moved before the train can continue.

If a train arrives across switch A, it must be returned to normal before it can proceed out of fthe middle tracks.

If a train arrives across switch B, then switch A must be reversed before it can continue.

LION makes it sound complicated, but it is simple railroad interlocking protocol, and indeed levers should also be required for the signals as well as for the switch points, but that, in HO is not necessary, although I do it that way anyway.

ROAR

The Route of the Broadway Lion The Largest Subway Layout in North Dakota.

Here there be cats.                                LIONS with CAMERAS

  • Member since
    February 2008
  • 8,878 posts
Posted by maxman on Friday, February 28, 2014 1:47 PM

BroadwayLion
There is a reversing loop.

I believe that that was determined 4 posts ago.

 

And I don't think I would have put the gaps where you show them.  I would have put them on the other track to the right of A, and after the crossover where you show the gap on the right side.

  • Member since
    July 2006
  • From: North Dakota
  • 9,592 posts
Posted by BroadwayLion on Friday, February 28, 2014 4:40 PM

I did not do that... because the inner track appears to be the main line with most of the traffic on it and all of the switching on it. Of course I do not see what the rest of the layout looks like so I can not discern his operating agenda, but the middle track is the problem, if it were gone there would be no reversing loop.

A train using a "cut-off" (If that is what it is) would have to hold at either end of the cut off for the tower to allow it back onto the mane lion.

LIONS always have reasons. There may be reasons for otherwise, but those are mine for this.

 

ROAR

The Route of the Broadway Lion The Largest Subway Layout in North Dakota.

Here there be cats.                                LIONS with CAMERAS

  • Member since
    September 2004
  • From: Dearborn Station
  • 24,281 posts
Posted by richhotrain on Friday, February 28, 2014 5:00 PM

I hate to admit this, LOL, but I agree with LION.  The way he gapped the reversing section is the way that I advised the OP.  But, maxman's approach would work just as well.

Rich

Alton Junction

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!