on Saturday, January 4, 2003 3:40 PM
I just got a 30 year old Marklin HO model train for xmas. The transformer nameplate says 125 volts @ 50 hz. Can I run it on 60 hz? Also is the train power DC or AC? The nameplate doesn't say.
Reply
Edit
Anonymous
Member since
April 2003
305,205 posts
Posted by
Anonymous
on Saturday, January 4, 2003 4:34 PM
NO! Do not use that transformer. The transformer converts AC to DC, in Europe you would probably get 24 volts DC out of it, but here in America you would probably get 18 volts DC. It might be good enough, but I would rather get an American transformer, 120 volts @ 60 hz to get the needed 24 volts DC and current. If the transformer had said 50-60 hz, then it would be okay, but since it didn't, it probably won't run well.
The train itself will more than likely run nicely with an American transformer.
Reply
Edit
Jackflash
Member since
August 2002
259 posts
Posted by
Jackflash
on Saturday, January 4, 2003 4:46 PM
when the AC current is rectified to DC the
50 Hz is not an issue, as its direct now
not alternating.
use a volt meter and see what the xformer out-
put is, if its DC you wont have any problems
even if it was AC it probably would still work
but the motors will turn faster with 60 Hz here
in north america.
Reply
Anonymous
Member since
April 2003
305,205 posts
Posted by
Anonymous
on Saturday, January 4, 2003 8:08 PM
I used to play with Marklin HO (still have it all) . The trains are AC and are supplied by a third center rail. Yes you can run it on 50 or 60 hz, it doesn't matter , it works either way. Also, you can run the trains on DC but they won't reverse by changing the polarity, but otherwise work just as well. Many Marklin engines from 30 years ago have a manual reverser switch on the loco (many but not all)so you can manualy change direction. The AC transformer has a reverser. Weird stuff eh?! But its pretty neat.
Reply
Edit
Join our Community!
Our community is
FREE
to join. To participate you must either login or register for an account.