Trains.com

Wire Chief

4046 views
18 replies
1 rating 2 rating 3 rating 4 rating 5 rating
  • Member since
    June 2014
  • 11 posts
Wire Chief
Posted by fr8tman on Saturday, June 6, 2015 8:59 AM

What were the responsibilities of the wire chief than and now?

  • Member since
    May 2003
  • From: US
  • 25,292 posts
Posted by BaltACD on Thursday, August 27, 2015 6:54 AM

fr8tman

What were the responsibilities of the wire chief than and now?

Keep railroad owned communications lines operating - call the proper technician to repair problems that were discovered through trouble reports and line testing.  On my carrier there is no designated job of 'Wire Chief'

Wire Chief was the first regular (not extra board) job I was able to hold.

Never too old to have a happy childhood!

              

  • Member since
    September 2003
  • From: Omaha, NE
  • 10,621 posts
Posted by dehusman on Thursday, August 27, 2015 8:16 AM

fr8tman

What were the responsibilities of the wire chief than and now?

 
I haven't ever seen a "wire chief" position in the last 35 years.
 
Modern roads have signal and communication departments that keep track of the operations of the signal and communications systems: in track, wire, microwave, fiber optics, radio.

Dave H. Painted side goes up. My website : wnbranch.com

  • Member since
    November 2005
  • 4,190 posts
Posted by wanswheel on Thursday, August 27, 2015 11:19 AM

 

 

 

  • Member since
    December 2001
  • From: Denver / La Junta
  • 10,820 posts
Posted by mudchicken on Thursday, August 27, 2015 3:49 PM

At least where I was, the wire chief began to vanish about the same time as the early fax machines (about the size of a washing machine or dryer) showed up along with all the digital telephone systems. They became "communications supervisors" and nobody was needed to babysit the system 24 hours a day (insert Maytag Repairman schtick here).

Now if the dispatchers and operating bubbas get lonely, they just call the guy's phone and invite him (Whine) to come in.  

Mudchicken Nothing is worth taking the risk of losing a life over. Come home tonight in the same condition that you left home this morning in. Safety begins with ME.... cinscocom-west
  • Member since
    September 2010
  • 2,515 posts
Posted by Electroliner 1935 on Thursday, August 27, 2015 6:15 PM

With open wire stretching for miles along the track, the WC had to know how to use measurement test equipment to try to determine where a line was down or shorted to reduce the time spent by the maintainer to find the problem. A good WC could usually get it to within a mile or so. He (I'd be very suprised if there were any women) might be able to patch around it using other pairs but if a tree had come down and the whole pole line down, dispatching was difficult. He would use what info he got from the operators and train crews, and track people. The job came from the days of the telegraph before A.G. Bell and all you could do was measre the resistance of the line. Today they have radar like distance measuring devices to determine where opens, shorts, and other problems are on lines. But I suspect that few railroads have any open wire circuits today. All leased or Fibre Optic or Microwave. A century ago it was an art. They also had to know how circuits worked and were powered. 

  • Member since
    September 2014
  • 134 posts
Posted by JC UPTON on Thursday, August 27, 2015 6:24 PM

Back when Electrical Engineers were real Engineers, not just "Bit Pushers" !!

from the Far East of the Sunset Route

(In the shadow of the Huey P Long bridge)

  • Member since
    December 2001
  • From: Northern New York
  • 25,026 posts
Posted by tree68 on Thursday, August 27, 2015 6:43 PM

Today with fiber optics, the testers can tell down to a pretty tight tolerance where the problem is.  Heck, they can see where the splices are...

LarryWhistling
Resident Microferroequinologist (at least at my house) 
Everyone goes home; Safety begins with you
My Opinion. Standard Disclaimers Apply. No Expiration Date
Come ride the rails with me!
There's one thing about humility - the moment you think you've got it, you've lost it...

  • Member since
    May 2003
  • From: US
  • 25,292 posts
Posted by BaltACD on Thursday, August 27, 2015 6:52 PM

But when you are dealing with 3rd party vendors - as happens in many railroad communications links - when the trouble happens each of the parties involved begin pointing their fingers at each other claiming it is the other party's problem.  The joy of modern railroad communications.

Never too old to have a happy childhood!

              

  • Member since
    December 2007
  • From: Georgia USA SW of Atlanta
  • 11,919 posts
Posted by blue streak 1 on Thursday, August 27, 2015 7:04 PM

Mario's  posts about the Talgos seem to show much open wire.

  • Member since
    April 2005
  • From: Colorado Springs, CO
  • 3,590 posts
Posted by csmith9474 on Friday, August 28, 2015 12:42 PM

BaltACD

But when you are dealing with 3rd party vendors - as happens in many railroad communications links - when the trouble happens each of the parties involved begin pointing their fingers at each other claiming it is the other party's problem.  The joy of modern railroad communications.

 

We have relatively little service provided by "3rd party vendors". A lot of our sites do have cell backup, and possibly a T1 providing comms to the site (as well as some satellite), but most everything is on our private ip based microwave radio system. That system supports CTC, dispatch radio, phone, lan, PTC (VETMS), etc. From our mainline microwave sites, we often have a shot that feeds a yard or railroad facility. That is speaking strictly for the railroad that I am employed with.  

 

Smitty
  • Member since
    September 2010
  • 2,515 posts
Posted by Electroliner 1935 on Friday, August 28, 2015 3:40 PM

As some communications techs' like to say, "Troubles leaving here fine"

I also had a two year fight with my cable provider (Comcast) over intermittent ten second interuptions to service where the voice and picture would drop (digital sets would tile) and return. This was affecting an area of about two square miles. They kept wanting to send somebody to the house, and after that they would get a line tech who would change coaxial amplifiers but it kept occuring. After two years, a tenacious good line tech finally realized that it had to be upstream and started checking the Fiber Optics and found a spurring defective laser. No one wanted to think the problem could be in the F.O. system and not in the coaxial cable. 

  • Member since
    December 2001
  • From: Sunny (mostly) San Diego
  • 1,920 posts
Posted by ChuckCobleigh on Friday, August 28, 2015 4:02 PM

JC UPTON

Back when Electrical Engineers were real Engineers, not just "Bit Pushers" !!

We called it "shoving electrons" in those days.  Nowadays, with glass overtaking copper, it's "shoving photons" but you still need electrons to get them going.

  • Member since
    May 2003
  • From: US
  • 25,292 posts
Posted by BaltACD on Friday, August 28, 2015 4:10 PM

Just the kinds of troubles - and responses I was referring to in my previous post.  Whenever you have to deal with a 'vendor' their response will be - it's YOUR problem, not ours.

Never too old to have a happy childhood!

              

  • Member since
    April 2005
  • From: Colorado Springs, CO
  • 3,590 posts
Posted by csmith9474 on Friday, August 28, 2015 9:25 PM
Ah, gotcha. I was just speaking from our perspective. If we ain't doing our job, trains don't move and you have unhappy dispatchers.
Smitty
  • Member since
    September 2014
  • 134 posts
Posted by JC UPTON on Saturday, August 29, 2015 1:15 PM

All three times I visited San Diego, it was "summer" & we FROZE TO DEATH!!!

from the Far East of the Sunset Route

(In the shadow of the Huey P Long bridge)

  • Member since
    May 2003
  • From: US
  • 25,292 posts
Posted by BaltACD on Saturday, August 29, 2015 1:29 PM

csmith9474
Ah, gotcha. I was just speaking from our perspective. If we ain't doing our job, trains don't move and you have unhappy dispatchers.

Not saying that anyone isn't doing their jobs.  It's just that in doing their jobs they tend to blame the other party for the problem - and then the problem gets fixed and none of the parties will admit it was their fault.

Never too old to have a happy childhood!

              

  • Member since
    July 2010
  • From: Louisiana
  • 2,310 posts
Posted by Paul of Covington on Saturday, August 29, 2015 3:20 PM

BaltACD
It's just that in doing their jobs they tend to blame the other party for the problem - and then the problem gets fixed and none of the parties will admit it was their fault.

   I know exactly what you mean.   Over 50 years ago I was working at a mainframe computer site that communicated with remote terminals all over the state.   It was a running joke that everytime we reported a problem with a line, the phone company called back to say that they didn't find any problem, but the line mysteriously started working again.

_____________ 

  "A stranger's just a friend you ain't met yet." --- Dave Gardner

  • Member since
    September 2010
  • 2,515 posts
Posted by Electroliner 1935 on Saturday, August 29, 2015 5:14 PM

Oh, you are not the only one with that experience. With POTS (Plain Old Telephone Service) techs could get by with taping onto a working phone line but with data, which was active, it would cause errors until they got off it. 

Join our Community!

Our community is FREE to join. To participate you must either login or register for an account.

Search the Community

Newsletter Sign-Up

By signing up you may also receive occasional reader surveys and special offers from Trains magazine.Please view our privacy policy