Posted by Blind Bruce on Monday, March 19, 2007 4:41 PM

I had my Zephyr packed away for almost a year and now it has a strange problem.

I only have an oval right now with no gaps and feeders every three feet or so. The Zep powers up with "loco" and my BLI diesel switcher begins to run and the sound is on. But I have not even entered the address yet. I entered the correct address but it has the same symtoms, no control, no bell or horn, it just runs very slowly and has the generator whine.

I tried other locos with the same result although the BLI is the only one that actually moves.

Any suggestions? Can the command station be "reset"?

BB 

73

Bruce in the Peg

  • Member since
    June 2004
  • From: Pacific Northwest
  • 3,864 posts
Posted by Don Gibson on Monday, March 19, 2007 4:55 PM

SOUNDS LIKE your DCC receiving modules are not programed. What has changed?

You need to hear from somebody that shares your DCC system.

Don Gibson .............. ________ _______ I I__()____||__| ||||| I / I ((|__|----------| | |||||||||| I ______ I // o--O O O O-----o o OO-------OO ###########################
  • Member since
    July 2006
  • 3,264 posts
Posted by CAZEPHYR on Monday, March 19, 2007 5:00 PM
 Blind Bruce wrote:

I had my Zephyr packed away for almost a year and now it has a strange problem.

I only have an oval right now with no gaps and feeders every three feet or so. The Zep powers up with "loco" and my BLI diesel switcher begins to run and the sound is on. But I have not even entered the address yet. I entered the correct address but it has the same symtoms, no control, no bell or horn, it just runs very slowly and has the generator whine.

I tried other locos with the same result although the BLI is the only one that actually moves.

Any suggestions? Can the command station be "reset"?

BB 

 

If the LOCO is spelled out in the window, select the correct address for the model and press the loco button.  That engine should not be controllable.

 

  • Member since
    July 2006
  • From: Seattle WA
  • 1,233 posts
Posted by Hoople on Monday, March 19, 2007 5:06 PM
 Blind Bruce wrote:

I had my Zephyr packed away for almost a year and now it has a strange problem.

I only have an oval right now with no gaps and feeders every three feet or so. The Zep powers up with "loco" and my BLI diesel switcher begins to run and the sound is on. But I have not even entered the address yet. I entered the correct address but it has the same symtoms, no control, no bell or horn, it just runs very slowly and has the generator whine.

I tried other locos with the same result although the BLI is the only one that actually moves.

Any suggestions? Can the command station be "reset"?

BB 

Select the address, then bring the throttle to stop. Happens when you leave the throttle on at some speed before pushing the off button.
Mark.
  • Member since
    January 2005
  • From: Winnipeg Canada
  • 1,637 posts
Posted by Blind Bruce on Monday, March 19, 2007 7:45 PM

While I was waiting for a reply, the Zep was powered off but not unplugged. When the power button was pressed,The BLI started to move right away. I pressed loco and the correct address blinked. I pressed "exit" and the engine was controllable. I then stopped it and put in reverse and the engine would no longer respond.

Still wondering what to do.

BB 

73

Bruce in the Peg

  • Member since
    January 2007
  • From: Wake Forest, NC
  • 108 posts
Posted by Trekkie on Monday, March 19, 2007 8:20 PM
This is a guess, nothing experience behind it.

I would try and re-program one of your locos, or maybe reset the decoder & reset the zephyr to defaults. Maybe something that is stored in the items over the last year of not use got corrupted in memory due to lack of power applied to refresh it.
  • Member since
    February 2002
  • From: Mpls/St.Paul
  • 13,892 posts
Posted by wjstix on Tuesday, March 20, 2007 8:04 AM
 Blind Bruce wrote:

While I was waiting for a reply, the Zep was powered off but not unplugged. When the power button was pressed,The BLI started to move right away. I pressed loco and the correct address blinked. I pressed "exit" and the engine was controllable. I then stopped it and put in reverse and the engine would no longer respond.

Still wondering what to do.

BB 

I think you shouldn't have pressed "exit". 

I suspect what happened is the loco was running the last time you used the Zephyr, it hadn't been brought to a stop. When you powered up, it started running as per it's last instructions.

When you pressed LOCO (above) and the engine number started flashing, that means that number was the last one you used on the Zephyr...essentially it's asking you if you want to run that loco no. again, or want to input another ID.  If you press LOCO again while it's flashing the engine no., it will stop flashing and you will have acquired that engine, you should then be able to control it. 

Otherwise, while it's flashing, try putting the loco no. in again and then hit LOCO again. If that doesn't work, put the loco on the programming track and make sure you have the right ID no. for it. 

Stix
  • Member since
    February 2004
  • From: Elyria, OH
  • 2,586 posts
Posted by BRVRR on Tuesday, March 20, 2007 9:04 AM

Bruce,

Sign - Ditto [#ditto]

Stix has the right idea. When you pushed "Exit" you dispatched the loco.

Every once in awhile I experience the same problem with my Zephyr when the grandson just turns off the power to everything without bringing all of the throttles to stop.

BLI locos are touchy! I have a couple that had to be reset because of turning the power on and off too quickly. Before going to that extreme, put your loco on the programing track, push the program button until you see "page" in the window. Push "Loco" until you get 2 or 4 digit in the window. This depends on the number you are using for the address. Push the "read key", the key with the + sign. The Zephyr should tell you the address. With some BLI locos you might have to do this a couple of times to get a reading. Don't forget to "Exit" the programming mode.

If the address matches. Be sure you have the right throttle selected, Main (Zephyr), or one of the 'jump  ports' they sometimes confuse the issue. Put the loco on the track and try again. Push "Loco" type in the address you want and push "Loco" again. The address should remain in the window. Advance the throttle and see how it goes. If all of this doesn't work, I would suggest resetting the Loco. If none of your locos are responding, reset the Zephyr and try again.Banged Head [banghead]

Good luck!

Remember its your railroad

Allan

  Track to the BRVRR Website:  http://www.brvrr.com/

  • Member since
    January 2005
  • From: Winnipeg Canada
  • 1,637 posts
Posted by Blind Bruce on Tuesday, March 20, 2007 9:46 AM
Is there a procedure for resetting the Zep by itself?

73

Bruce in the Peg

  • Member since
    December 2001
  • 1,932 posts
Posted by Stevert on Tuesday, March 20, 2007 10:23 AM

 Blind Bruce wrote:
Is there a procedure for resetting the Zep by itself?

Yes.  Set OpSw 39 to "c".  See section 28.0 on page 46 of your manual for details.

 

Steve 

  • Member since
    February 2002
  • From: Reading, PA
  • 30,002 posts
Posted by rrinker on Tuesday, March 20, 2007 9:07 PM

 Steps to reset: Press PROG. Press SWITCH. Key in 39. Press C. Unplug the power cord and wait a few seconds, then plug it back in. All reset.

When selecting a loco, press LOCO, key in the number, press LOCO (witht he speed knob at stop, you don't want any surprises). When done running, make sure the loco is stopped and press LOCO then press EXIT.

 

                            --Randy
 

 


Modeling the Reading Railroad in the 1950's

 

Visit my web site at www.readingeastpenn.com for construction updates, DCC Info, and more.

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!