Posted by SloPace on Friday, December 16, 2016 12:56 PM
I've run into some wiring problems on my layout. In the past, I've used Atlas layouts where they tell you how to do everything.  Now I’m freelancing and getting a better understanding of what trial & error is.
I'm testing using DC controller Tech4 MRC280. I'll switch to DCC once I get the bugs out.
I'm using Atlas Snap-Switch code 100 nickel silver turnouts.
The problems:
Turnout A in the southeast corner, when connected to the tracks to north and east causes the overload light to come on. Testing with multimeter shows no power to tracks over the entire layout. If I disconnect one track, it doesn’t matter which one, power is available.
Section B connects 2 turnouts.  When connected, overload.
There are no connections to the bus in the southeast section.
This is above my skill level so I would appreciate any advice. 

 

Thanks.Train Layout
  • Member since
    September 2004
  • From: Dearborn Station
  • 24,280 posts
Posted by richhotrain on Friday, December 16, 2016 4:53 PM

A is a reverse loop where the track folds back onto itself. You can visualize the mismatched polarities where black connects to red and red connects to black. Since you are operating in DC, this will require a DPDT toggle switch to reverse polarities inside the loop while the train is inside the loop. Also, you will need to isolate the reverse loop from the rest of the layout by adding gaps.

B is a simple crossover between two tracks with matching polarities. Apparently, you have miswired the crossover. Assuming that you have added feeders to power the crossover, try flipping the two feeder wires.

Rich

Alton Junction

  • Member since
    February 2014
  • 3 posts
Posted by SloPace on Saturday, December 17, 2016 11:01 AM

Thanks.  I missed that on A.  It also looks like B is feeding into the reverse.  I do not have any bus connections in that area.  The only connection are above the area.  So I should isolate that connection also.

On the diagram, I've drawn lines where I think the isolators should be.  Am I correct?

I'm using DC just to get the connections straight.  I have a Digitrax Zephyr xtra that I will setup next.  

Is best way to handle it to use a toggle switch or setup a power district with a booster & auto reverse module?

Appreciate the help.

Bob Pace

  • Member since
    March 2015
  • 1,358 posts
Posted by SouthPenn on Saturday, December 17, 2016 12:47 PM

In section/switch B, if the switches have powered frogs and change polarity with the switch points, the two swtches cannot be connected to each other through the crossover. Using insulating joiners on the diverging routes of the switches will fix the problem. 

South Penn

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!