Posted by 1butlerhawk on Thursday, April 28, 2016 2:35 PM

I posted this question a bit earlier, but it apparently was not accepted.  My problem concerns a short section of track.  For some reason I have it wired in two places and the wires reun directly to the X and Y terminals on the Atlas Controller which is connected to the power source.  I have to run the train on this track section by having the Controller in the Cab B center postion; the Cab selector on B and must run the train by using the Controller direction switch.  When running the train (which incidently does not run well) the power source overload light comes on from time to time - perhaps a short, but if so I do not know how to find such a short.  This is the only wiring in my layout hooked up to the X and Y Controller terminals.  The rest of my layout I operate with Atlas Selectors.  I would like to wire this section of track the same way as the rest of the layout, but frankly I do not remember how I did this.  My age (85) must be catching up to me so I do need some help; the other problem is that I did no work or used the layout for over a year.  Any help you may give me will be most appreciated.  Thank you very much. 

  • Member since
    January 2015
  • From: Southern California
  • 1,682 posts
Posted by Lone Wolf and Santa Fe on Friday, April 29, 2016 3:43 PM

Is that short section of track a wye or reverse loop? That might be the reason you hooked it up to the x and y. You might have too many sets of wires to that section. Also you should clean your track if you haven’t used it in a long time.

Maybe this diagram can help.

Modeling a fictional version of California set in the 1990s Lone Wolf and Santa Fe Railroad
  • Member since
    July 2006
  • From: North Dakota
  • 9,592 posts
Posted by BroadwayLion on Friday, April 29, 2016 3:51 PM

Welcome

Manke sure that the left rail is consistantly wired to the same terminal, and that the right rail is wired to the other terminal. Trace these you with your fingers all the way around the layout. If you pass through a "reversing loop" your finger will end up on the wrong rail. You will need more gaps and controls to fix this situation.

Otherwise, wiring is NOT all that complicated...

ROAR

The Route of the Broadway Lion The Largest Subway Layout in North Dakota.

Here there be cats.                                LIONS with CAMERAS

  • Member since
    July 2006
  • 118 posts
Posted by Texas Zephyr on Saturday, April 30, 2016 9:18 PM

1butlerhawk
My problem concerns a short section of track.  For some reason I have it wired in two places and the wires reun directly to the X and Y terminals on the Atlas Controller which is connected to the power source.

If the layout is properly wired, that would indicate that it is a reversing section (reversing loop or wye). 

I cannot explain why it would develop a short or other issues over a year of unuse.  But, common wire schemes can do strange things if one of the "common" wires come loose.  So that is the first thing I would check.  Make certain all the wires are really connected, not just hanging on by a piece of insulation.

My next guess is that some dust - dirt - or moisture got into the unit and is causing it to behave that way.  You could test this with a multi-meter directly off the screws on the Atlas Controller.

  • Member since
    February 2007
  • From: Shenandoah Valley The Home Of Patsy Cline
  • 1,842 posts
Posted by superbe on Monday, May 2, 2016 2:33 PM

1butlerhawk

As suggested the finger test and the multimeter should define your problem.

I notice this is only your third post and I hope you won't take offense when I say that responding to a question with what solved or didn't solve the problem is helpful to those answering and reading this thread

Good luck

Bob

  • Member since
    December 2001
  • From: Northern CA Bay Area
  • 4,387 posts
Posted by cuyama on Monday, May 2, 2016 2:36 PM

1butlerhawk
I posted this question a bit earlier, but it apparently was not accepted.

It seems like this might have been the same problem that you posted earlier, and there were some replies that might be helpful.

http://cs.trains.com/mrr/f/88/t/255893.aspx

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!