Trains.com

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

DC powerpack for American Flyer

2673 views
9 replies
1 rating 2 rating 3 rating 4 rating 5 rating
  • Member since
    February 2013
  • 10 posts
DC powerpack for American Flyer
Posted by oroborus on Tuesday, February 5, 2013 8:08 AM

I would appreciate suggestions for DC powerpacks capable of driving  American flyer DC and AC  cast engines,
with  some indication of quality and  effectiveness.
Thanks for your help.

  • Member since
    July 2003
  • From: Sierra Vista, Arizona
  • 13,757 posts
Posted by cacole on Tuesday, February 5, 2013 8:28 AM

What scale are these American Flyer locomotives you are asking about.  The AF S-scale engines required AC power and probably won't run on DC.  Their HO scale locomotives, IIRC, run on DC power.

  • Member since
    February 2013
  • 10 posts
Posted by oroborus on Tuesday, February 5, 2013 8:37 AM

Thanks for your reply but see this thread:http://cs.trains.com/ctt/f/95/t/199136.aspx

  • Member since
    November 2002
  • From: Colorado
  • 4,075 posts
Posted by fwright on Tuesday, February 5, 2013 11:46 AM

oroborus

I would appreciate suggestions for DC powerpacks capable of driving  American flyer DC and AC  cast engines,
with  some indication of quality and  effectiveness.
Thanks for your help.

The current draw will be the biggest issue.  While I'm more familiar with Lionel, the situation is pretty much the same.  If your engine/train draws 3 amps (takes a 50 watt transformer to run it), then you need at least 36VA (or a 3 amp output @ 12 volt rating) from the DC power pack for that one engine/train.  There weren't a lot of DC powerpacks made in recent years with that kind of output.  You will probably have to look through the used MRC powerpacks.

An alternative if the voltage control is pretty good on your existing transformers is to attach a rectifier to the output, and use the transformer speed control to control voltage through the rectifier.  A 5 amp, 50 volt full wave bridge is not difficult to find.

Another practical alternative is to build your own DC transistor throttle, and again use your existing transformer for the AC input.  Do a search for DC throttles for circuits, then make sure the circuit can handle 3-5 amps output.  You WILL need good heat sinks for the power transistors to handle that kind of power.  This can be a really excellent setup.

Some of the G (large scale ) power packs will also likely provide the DC power you need, but will probably be costly.

Your post-war engines may also need around 14-16 volts to obtain a decent speed.

I assume you understand that the E units on the field wound motors may or may not work correctly with DC power.  You may have to replace the E units with electronic versions intended for use with DC (Dallee is a source).  Or possibly use a rectifier bridge in place of the E unit to control the polarity of the field windings (I've forgotten the details since leaving the Lionel world).

my thoughts, your choices

Fred W

  • Member since
    February 2013
  • 10 posts
Posted by oroborus on Tuesday, February 5, 2013 1:25 PM

Thanks for your reply(excellent info), but being new to model railroading my electrical ability is limited and I was looking for something out of the box.The G units might be the ticket I'll keep diggin'.

  • Member since
    September 2004
  • From: Dearborn Station
  • 24,193 posts
Posted by richhotrain on Tuesday, February 5, 2013 3:22 PM

You should direct that question to the guys on the Classic Toy Trains forum.'

Rich

Alton Junction

  • Member since
    February 2013
  • 10 posts
Posted by oroborus on Tuesday, February 5, 2013 3:25 PM

Thanks.I'l ltry that.

  • Member since
    September 2004
  • From: Dearborn Station
  • 24,193 posts
Posted by richhotrain on Tuesday, February 5, 2013 4:10 PM

Not trying to throw you off this forum, but there are some very knowledgeable American Flyer guys on the CTT forum, although it is dominated by (gag) Lionel guys - - - LOL

Ahh, spoken like a true Flyer guy.

Good luck !

Rich

Alton Junction

  • Member since
    February 2013
  • 10 posts
Posted by oroborus on Tuesday, February 5, 2013 5:26 PM

I've been thrown out of better places than this!...LOL

  • Member since
    September 2004
  • From: Dearborn Station
  • 24,193 posts
Posted by richhotrain on Tuesday, February 5, 2013 5:47 PM

oroborus

I've been thrown out of better places than this!...LOL

Look at it this way.  If we will have you as a member, you don't want to be here.  Laugh

Rich

Alton Junction

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!