I'm wiring up to internal switch for the frog. i was wondering
if you can wire to the buss line instead of using the stock rails?
It would make the job a lot simpler.
thanks in advance
scotcamper wrote:I'm wiring up to internal switch for the frog. ... can wire to the buss line instead of using the stock rails?
Using the same circuit with twin-coil machines, I always wire directly to the bus terminals on the nearest terminal strip. That way, if there's an electrical glitch it can be isolated much more easily. Also, my terminal strips are all accessible from the aisleway, which saves me from having to crawl into the underworld to check circuitry.