Trains.com

Why am I confused

1669 views
8 replies
1 rating 2 rating 3 rating 4 rating 5 rating
  • Member since
    December 2010
  • 81 posts
Why am I confused
Posted by Dobson on Saturday, December 15, 2012 8:37 AM

I am in the process of rewriting my layout (to use buss wiring) and I am confused on hooking back up a few accessories. Perhaps you guys can assist.?  

I am hooking up a barrel loader, log ramp, gateman, coaling station and the instructions are ambiguous on which line goes through the switch to the hot or which goes to the ground. Most of the postwar instructions just say go to the variable posts but not which ones. 

Does it matter in most cases or do I just need to complete the circuit by one going to hot and the other to ground?

  • Member since
    January 2005
  • From: Lake Worth FL
  • 4,014 posts
Posted by phillyreading on Saturday, December 15, 2012 9:00 AM
I would keep all the wiring the same, if a black wire goes to nuetral or common then use that or if a red wire goes to a hot terminal use that. Another thing to consider, do any of your accessories have a track going to them like the coal loader? You may want to check if the frame of the coal loader is metal and if the accessory gets any feed-back from the track, with tubular track the crossties are metal and have the outside rail's polarity from the transformer. Another thing to consider is the signal light posts and crossing signals, if near a track is the frame metal, if so you need to make sure the frame if powered uses the outside rail's power, main concern is derailments.
Interested in southest Pennsylvania railroads; Reading & Northern, Reading Company, Reading Lines, Philadelphia & Reading.
  • Member since
    April 2007
  • From: MICH
  • 8,153 posts
Posted by sir james I on Saturday, December 15, 2012 9:05 AM

Most would put the switch on the 'hot" side but it will work either way, you are just breaking the circuit. BUT do them all the same or over time you will forget which is which. Some things like the gateman do not normally use an on/off switch.

"IT's GOOD TO BE THE KING",by Mel Brooks 

  Charter Member- Tardis Train Crew (TTC)   - Detroit3railers-  Detroit Historical society Glancy Modular trains- Charter member BTTS

  • Member since
    December 2010
  • 81 posts
Posted by Dobson on Saturday, December 15, 2012 9:10 AM

That is what I thought. Run all hot through the 364c's

  • Member since
    January 2005
  • From: Lake Worth FL
  • 4,014 posts
Posted by phillyreading on Saturday, December 15, 2012 9:14 AM
I forgot about the gateman, you may also need a contact unit under the track that makes and brakes the circuit electrically, I forget the part number. Or you can use a trip section of track that is insulated from the other outside rail with the gateman. If you don't have either of those or don't know how to use them, then a doorbell button will work as it is a momentary contact style switch.
Interested in southest Pennsylvania railroads; Reading & Northern, Reading Company, Reading Lines, Philadelphia & Reading.
  • Member since
    January 2005
  • From: Lake Worth FL
  • 4,014 posts
Posted by phillyreading on Saturday, December 15, 2012 9:15 AM
Dobson

That is what I thought. Run all hot through the 364c's

Is the 364C a new part number for Fastrac?
Interested in southest Pennsylvania railroads; Reading & Northern, Reading Company, Reading Lines, Philadelphia & Reading.
  • Member since
    December 2010
  • 81 posts
Posted by Dobson on Saturday, December 15, 2012 9:15 AM

I have that hooked up on the outside rail via an operating section of fastrack. 

  • Member since
    December 2010
  • 81 posts
Posted by Dobson on Saturday, December 15, 2012 9:18 AM

No it is a postwar on off switch

  • Member since
    April 2007
  • From: MICH
  • 8,153 posts
Posted by sir james I on Saturday, December 15, 2012 9:19 AM

The 364c is the old Lionel on/off switch. The under the track pressure plate is a 153c.

"IT's GOOD TO BE THE KING",by Mel Brooks 

  Charter Member- Tardis Train Crew (TTC)   - Detroit3railers-  Detroit Historical society Glancy Modular trains- Charter member BTTS

Join our Community!

Our community is FREE to join. To participate you must either login or register for an account.

Search the Community

FREE EMAIL NEWSLETTER

Get the Classic Toy Trains newsletter delivered to your inbox twice a month