Posted by Enzoamps on Tuesday, July 18, 2017 9:34 PM

As an electronics professional in my working days, I am always intersted in circuits.  I was looking at a photo of Washington Union Station tracks with catenary all over the place.  I realize the power all comes from one source.  But in general in a setting like that, are all the wires essentially wired together, one big criss-cross grid?  Or does each track have its own branch circuit?  I am sure there are breakers cordoning it off into sections.  So for example on a two track main, would the two stripes of wire be on separate breakers?  Or would it be just one for the pair.  Any other considerations I haven't thought of?

  • Member since
    February 2005
  • 2,366 posts
Posted by timz on Wednesday, July 19, 2017 12:26 PM

Guess any electrified RR can shut off power to one track while running trains on the other tracks? To allow work on the catenary, if nothing else?

  • Member since
    June 2002
  • 20,096 posts
Posted by daveklepper on Wednesday, July 19, 2017 1:26 PM

I think one of the frequent posters has some hands-on experience with this matter, but I believe there is a NEC ex-PRR power control room, probably within the 30th Street, Philadelphia complex, or at Zoo or N. Phila., with essentially a wire-and-track map of the entire system from New Rochelle to Harrisburg and the current end of wire in the tunnel south of Union Station.  Insulation breaks are shown, each section has its own push-to-cut-power button (and possibly push a second time to restore) and some lights to give a report on conditions.  Metro-North-Connecticut-DOT has its own, and probably Amtrak New Haven - Boston is another.  Before my move to Israel, Sunnyside - New Rochelle was controlled in the same room as Woodlawn - New Haven, but I am pretty certain that is now controlled in the same room as Sunnyside -Harrisburg and Washington.

Individual tracks in each station can be switched on and off, and ditto each track in each section in multi-track RoW.

But I expect to be corrected in one detail matter or another.  Like my false memory of New Haven 6-10 sleepers.  Rode them over a hundred times too.  But they were not 6-10s.

  • Member since
    June 2002
  • 20,096 posts
Posted by daveklepper on Wednesday, July 19, 2017 1:29 PM

I should also point out that the power room has control circuits, not the actual power.  Power is fed from the substations spaced along the line with on-off relays controlled from the power room.

  • Member since
    December 2007
  • From: Georgia USA SW of Atlanta
  • 11,919 posts
Posted by blue streak 1 on Wednesday, July 19, 2017 9:17 PM

daveklepper

I should also point out that the power room has control circuits, not the actual power.  Power is fed from the substations spaced along the line with on-off relays controlled from the power room. 

Any one know the various steps to verify the power is off and stays off ?  The old PRR equipment certainly would make one very cautious that power is off and stays off.  Wonder if any equipment will be replaced ?

  • Member since
    September 2011
  • 6,449 posts
Posted by MidlandMike on Wednesday, July 19, 2017 9:18 PM

The NEC is single phase, but the power supply is presumably 3 phase.  I am guessing that the 3 phases are distributed to different tracks to try to even out power usage.

  • Member since
    December 2007
  • From: Georgia USA SW of Atlanta
  • 11,919 posts
Posted by blue streak 1 on Wednesday, July 19, 2017 9:25 PM

MidlandMike

The NEC is single phase, but the power supply is presumably 3 phase.  I am guessing that the 3 phases are distributed to different tracks to try to even out power usage.

Nope.  PRR power supply is actually single phase.  Note power lines are in pairs.   Power is just like what comes into your home.  Feeders to ground are 180 degrees out of phase so voltage feeder to feeder is twice that of feeder to ground.

Safe harbor generators provide this unique high voltage power. If comercial 3 phase power is used at power stations then.  Phase balancing is actually done with motor generators called rotary converters in PRR dictionary.  Or done electronically at the new Siemens power station being built in NJ.   Also there are some phase balancing transformers.

  • Member since
    September 2011
  • 6,449 posts
Posted by MidlandMike on Thursday, July 20, 2017 8:43 PM

blue streak 1

 

 
MidlandMike

The NEC is single phase, but the power supply is presumably 3 phase.  I am guessing that the 3 phases are distributed to different tracks to try to even out power usage.

 

 

Nope.  PRR power supply is actually single phase.  Note power lines are in pairs.   Power is just like what comes into your home.  Feeders to ground are 180 degrees out of phase so voltage feeder to feeder is twice that of feeder to ground.

Safe harbor generators provide this unique high voltage power. If comercial 3 phase power is used at power stations then.  Phase balancing is actually done with motor generators called rotary converters in PRR dictionary.  Or done electronically at the new Siemens power station being built in NJ.   Also there are some phase balancing transformers.

 

Does mean that the rotary converters convert 60 Hz 3 phase directly to 25 Hz single phase?

  • Member since
    December 2001
  • From: Northern New York
  • 25,021 posts
Posted by tree68 on Thursday, July 20, 2017 9:13 PM

MidlandMike
Does mean that the rotary converters convert 60 Hz 3 phase directly to 25 Hz single phase?

Actually, I believe they might just do that.  Either by how they are wired, or via gear reduction...

LarryWhistling
Resident Microferroequinologist (at least at my house) 
Everyone goes home; Safety begins with you
My Opinion. Standard Disclaimers Apply. No Expiration Date
Come ride the rails with me!
There's one thing about humility - the moment you think you've got it, you've lost it...

  • Member since
    December 2005
  • From: Cardiff, CA
  • 2,930 posts
Posted by erikem on Thursday, July 20, 2017 11:13 PM

MidlandMike

Does mean that the rotary converters convert 60 Hz 3 phase directly to 25 Hz single phase?

 
The "rotary converters" are more accurately named frequency changers sets, being composed of a 300rpm 24 pole 60 Hz synchronous motor coupled directly to a 10 pole single phase synchronous generator. There is a frame shifting arrangement on the set to allow for adjusting the power flow through the 25Hz lines as oppposed to the 60Hz lines.
  • Member since
    July 2008
  • 2,325 posts
Posted by rdamon on Friday, July 21, 2017 7:16 AM

Lots of woodworkers use rotary converters to create three phase power at their home work shops that are fed by single phase power.

https://www.americanrotary.com/

RME
  • Member since
    March 2016
  • 2,073 posts
Posted by RME on Friday, July 21, 2017 8:03 AM
  • Member since
    July 2008
  • 2,325 posts
Posted by rdamon on Friday, July 21, 2017 10:37 AM
  • Member since
    December 2007
  • From: Georgia USA SW of Atlanta
  • 11,919 posts
Posted by blue streak 1 on Friday, July 21, 2017 7:47 PM

rdamon

 
Very interesting article.  Can now understand why PRR, Reading, and New Haven RRs all started with 25 Hz 11 kV CAT.  Statement by author that he did not know of any operating rotary converters is puzzling.  He may have been only referring to 25 hZ to DC converters.  We Know Amtrak still uses 60 hZ to 25 hZ converters.
Also the use of Ignition rectifiers and later Ignitron rectifers that led to their later use on RR locos. 
  • Member since
    December 2005
  • From: Cardiff, CA
  • 2,930 posts
Posted by erikem on Friday, July 21, 2017 11:36 PM

rdamon

Lots of woodworkers use rotary converters to create three phase power at their home work shops that are fed by single phase power.

https://www.americanrotary.com/

 

These were traditionally called phase converters, essentially being a free running three phase synchronous or induction motor with the single phase input connected across one winding and the three phase output connected across all three windings. Some means is needed to get the rotor turning as with any single phase induction or synchronous motor.

The N&W electrics, the VGN Squareheads and the PRR Big Liz all used phase converters.

The term "rotary converter" traditionally referred to machines that combined a stationary field synchronous motor armature with a shunt wound DC generator. The armature windings would be connected to AC fed slip rings on one end and a DC fed commutator on the other end. Most of the power transfer between AC and Dc was through the windings as opposed to torque generated by the armature.

Rotary converters could also be used to convert DC to AC, with small units being used in the DC districts of major cities to provide AC power.

As I wrote before, the frequency changer set in Safe Harbor was/is a motor generator set. This is very different from the traditional meaning of "rotary converter".

 - Erik

RME
  • Member since
    March 2016
  • 2,073 posts
Posted by RME on Saturday, July 22, 2017 12:24 AM

I find myself impatient for Rick Rowlands to finish up with his red Glyptal and get this running for at least one Youtube video, replete with zarks and other mad-scientist effects:

https://www.flickr.com/photos/33523379@N03/15178605648/in/album-72157647667854548

  • Member since
    August 2005
  • From: At the Crossroads of the West
  • 11,013 posts
Posted by Deggesty on Saturday, July 22, 2017 8:07 AM

Quoting Erikem: "These were traditionally called phase converters, essentially being a free running three phase synchronous or induction motor with the single phase input connected across one winding and the three phase output connected across all three windings. Some means is needed to get the rotor turning as with any single phase induction or synchronous motor."

When I was working and issuing replacements to the line maintenance people, I was amazed that the techs could not look a the motor on a vacuum pump and tell if it were a single phase or three phase motors, for each of the single phase motors had one or more capacitors on it to give the motor a jump start. At firt, we kept all pumps of a certain size under one part number, but we made life easier on the techs by giving pumps with a single phase motor one p/n and pumps with a three phase motor a diffierent p/n.

Johnny

  • Member since
    September 2010
  • 2,515 posts
Posted by Electroliner 1935 on Saturday, July 22, 2017 6:48 PM

As an electrical engineer who was used to three phase power, I found this article of interest:

https://en.wikipedia.org/wiki/Amtrak%27s_25_Hz_traction_power_system

I had observed the transmission lines along the former PRR ROW and for some reason thought they were two phases of a three phase system and that the catanary made up the third phase. No. They are a single phase 69 kv to ground 138 kv phase to phase line and a second line on the other side of the ROW. I felt so dumb when I learned that I didn't know that. Utilities need balanced loads on their 3 phase lines and I should have known better. 

As Johny Carsons sidekick used to say, "EVERY THING YOU NEED TO KNOW" is in the wikipedia article.

  • Member since
    December 2005
  • From: Cardiff, CA
  • 2,930 posts
Posted by erikem on Saturday, July 22, 2017 7:58 PM

Back in the early years of electrification, when there were a few three phase electrifications (GN old Cascade tunnel, many lines in Italy), single phase electrifications were specifically called single phase.

While the ex-PRR 25Hz power tramission system is impressive, it is small potatoes compared to the 16 2/3Hz transmission system in Germany. The low frequency was originally used to allow for use of AC series (universal) motors.

  • Member since
    December 2007
  • From: Georgia USA SW of Atlanta
  • 11,919 posts
Posted by blue streak 1 on Saturday, July 22, 2017 10:45 PM

Seveal other sites have had various criticisms of the cost over runs for the first phase of the constant tension CAT installation. 

1.  The replacement of present transmission poles due to their rusting out below grouns level.  Using different methods to prolong poles.

2.  Related to #1 is that poles are being placed closer than originals. Allows shorter spacing of cross poles that support CAT.   That can be explained due to the problem of harmonic oscillations of the CAT under higher speed trains and also that NJT wants to run longer EMU trains with more PANs contacting which could cause possible oscillations.

Pictures of the  work seem to show cross beams are being set at a much higher height.  May be  to allow Amtrak to raise CAT height above rail ?   Possible plate "H" clearance ?

3.  Extra heavy and extra tensioning of guy wires both parallel to tracks and cross wise.  Trying to keep constant tension in spec ?  Attach poles for weights will need extra guy wires.

 

Thoughts ?

  • Member since
    June 2002
  • 20,096 posts
Posted by daveklepper on Sunday, July 23, 2017 2:26 PM

I should note that although New Haven - Boston has been added to the NEC electrification, we have lost (1) Washington - Patomic Yard (including the Virginina Avenue freight rout, (2) Harrisburg - Enola Yard, (3) Newark - Waverly and Greenville, (4) Port Deposit - Harrisburg, and (4) Trenton Cutoff (does this track still exist?).

Part of the (3) still has electrification, 3rd-rail 600V DC for PATH and that part is owned by PATH now.

  • Member since
    September 2011
  • 6,449 posts
Posted by MidlandMike on Sunday, July 23, 2017 9:40 PM

blue streak 1

Seveal other sites have had various criticisms of the cost over runs for the first phase of the constant tension CAT installation. 

1.  The replacement of present transmission poles due to their rusting out below grouns level.  Using different methods to prolong poles.

2.  Related to #1 is that poles are being placed closer than originals. Allows shorter spacing of cross poles that support CAT.   That can be explained due to the problem of harmonic oscillations of the CAT under higher speed trains and also that NJT wants to run longer EMU trains with more PANs contacting which could cause possible oscillations.

Pictures of the  work seem to show cross beams are being set at a much higher height.  May be  to allow Amtrak to raise CAT height above rail ?   Possible plate "H" clearance ?

3.  Extra heavy and extra tensioning of guy wires both parallel to tracks and cross wise.  Trying to keep constant tension in spec ?  Attach poles for weights will need extra guy wires.

 

Thoughts ?

 

Photos of standard PRR catenary set-up shows the catenary poles on a (cement?) foundation.  Where did they rust out?

Are the cost over-runs because they did not anticipate replacing poles, or closer spaced poles?

  • Member since
    December 2007
  • From: Georgia USA SW of Atlanta
  • 11,919 posts
Posted by blue streak 1 on Sunday, July 23, 2017 9:48 PM

MidlandMike

 Photos of standard PRR catenary set-up shows the catenary poles on a (cement?) foundation.  Where did they rust out?

Some other sites say that some of the poles actually go through the concrete caps and into the ground ?  It will take some one near by to clarify ? 

Are the cost over-runs because they did not anticipate replacing poles, or closer spaced poles?

Some one posted a OIG report about that but cannot find it ? 

 

  • Member since
    December 2001
  • From: NW Wisconsin
  • 3,857 posts
Posted by beaulieu on Sunday, July 23, 2017 10:49 PM

Switzerland also had 3-phase electrification through the Simplon Tunnel to Domodossola, Italy. This was extended west along the Rhone Valley to Sion during WW1 due to the extreme shortage of coal.  Two of Switzerland's highest climbing rack railways still use 3-phase power. The Gornergratbahn which climbs from Zermatt to the summit of the Gornergrat at 10,135 ft. The second is the Jungfraubahn which climbs from Kleine Scheidegg through two mountains to the station at Jungfraujoch at 11,709 ft., the highest railway station in Europe.

  • Member since
    May 2012
  • 5,017 posts
Posted by rcdrye on Monday, July 24, 2017 7:30 AM

Switzerland's B-L-S was electrified from the beginning at 15KV 16 2/3 hz single phase.  The Burgdorf Thun Bahn (part of todays Regionalvehrkehr Mittelland (RM)) had an early (1899) three phase (Drehstrom) electrification (750 v 40 Hz) which connected with the BLS at Thun, converted to 50 Hz in 1920, converted 1932/1933 to single phase to deal with otherwise impossible crossings and joint track.

  • Member since
    April 2015
  • 469 posts
Posted by Enzoamps on Tuesday, July 25, 2017 3:52 AM

Thank you for the interesting discussion.  I understand three-phase transmission, and motors.   But how would you provide three-phase power to a locomotive?  I see track, presumably at ground, and a single overhead catenary wire - two conductors.  How can we get three-phase from that into the locomotive?

  • Member since
    June 2002
  • 20,096 posts
Posted by daveklepper on Tuesday, July 25, 2017 4:26 AM

Three-phase electrifications generally had two trolley wires, or two catenaries, spaced about 0.8 meters, slightly under three feet, apart, with the track being the third conductor.  Rode Tirano - Sondrio, Italy, on the Via Alpina Railway, Spring 1960, after riding Ratian Railways, Ratischa Bundesbahn, meter-gauge, San Moritz, Switzerland - Tirano.  The car I was riding (rear) was switched to the rear of streamlined articulated 3000V DC unit in Sondrio for the trip to Milan.  The 3-phase loco was a steeplecab with two full-diamond pantographs side-side on the cab roof.

A friendly Italian family insisted on my sharing their copious meal.  Lot of bread, cheese, pasta, tomato sauce, eggplant, don't remember the meat and may have avoided it.

  • Member since
    November 2011
  • 40 posts
Posted by LehighLad on Monday, July 31, 2017 7:42 PM

rdamon

Regarding (as mentioned in Part II of the article) motor-generator sets to supply 25-cycle power to the Bethlehem Steel plant in Bethlehem PA, in 1954 I was inside that plant, as an employee of Pennsylania Power and Light Co. (PP&L), for testing of some equipment now unremembered.  I found it intriguing to observe that, in the building I was working in, there was a 60-cycle AC generator that was running as a motor, shaft-coupled to a 25-cycle synchronous motor, this latter running as a generator to supply 25-cycle power. In use the combination would've possibly been started up from the 25-cycle side (if such bus voltage was available), via the motor's amortisseur winding, and then synchronized with the 60-cycle mains. It was a very interesting example of the reversibility property of synchronous AC machines.