Trains.com

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Consist question

1311 views
7 replies
1 rating 2 rating 3 rating 4 rating 5 rating
  • Member since
    October 2003
  • 571 posts
Consist question
Posted by hwolf on Friday, June 14, 2024 4:41 PM

I have two engine that I want to run together. If I match there speed, one is running at 60mph on the throttle and the other is at 80mph.

I am running a MRC Controller. If I use the consist setting on the MRC how are they running at the same speed?  I don't want to hirt one of the engines trying to pull the other at the wrong speed.

Harold

  • Member since
    July 2006
  • From: Central Vermont
  • 4,563 posts
Posted by cowman on Friday, June 14, 2024 7:04 PM

I'm not familiar with the MRC controller but if your locos are going at the same speed on the tracks is what is important.  The speed on the controller is only a guide.  Be sure that they are running at the same speed throughtout the full speed range.  To check mine I run the two locos a few inches apart several times around the layout.

Good luck,

Richard 

  • Member since
    October 2005
  • 1,045 posts
Posted by betamax on Saturday, June 15, 2024 8:22 AM

hwolf

I have two engine that I want to run together. If I match there speed, one is running at 60mph on the throttle and the other is at 80mph.

I am running a MRC Controller. If I use the consist setting on the MRC how are they running at the same speed?  I don't want to hirt one of the engines trying to pull the other at the wrong speed.

Harold

 

 

First, you will need to match the speed of each locomotive. There are CVs in the decoder which allow that, if the decoder supports those features. Back EMF may also introduce some issues. The decoder may (or may not) include a speed table which allows finer adjustements.

Speed Matching

Consisting

The speed is controlled within the decoder, not by the controller. It just sends a command to use this speed step, the actual speed is determined by the decoder, motor, and gearing. Even two identical models can have slight differences.

  • Member since
    September 2014
  • From: 10,430’ (3,179 m)
  • 2,296 posts
Posted by jjdamnit on Saturday, June 15, 2024 2:42 PM

Hello All,

hwolf
I have two engine(s) that I want to run together. If I match there (SIC) speed, one is running at 60mph on the throttle and the other is at 80mph.

What you are describing is not "speed matching."

If they are truly "speed matched" they will both run at the same speed at the same throttle settings, whether consisted or not.

A component of "speed matching" is the setting of the Voltage Start (V Start; CV 02), Voltage Mid (V Mid; CV 06) and Voltage Max (V Max; CV 05).

The decoder(s) need to support these CVs for accurate speed-matching. Some older or inexpensive decoders don't support these CVs.

There are many videos on YouTube describing how to speed match using the above CVs.

hwolf
If I use the consist setting on the MRC how are they running at the same speed?

Do you know what method of consisting MRC uses: Basic, Universal, or Advanced (this has nothing to do with speed matching)?

  • Basic Consisting: When all locomotives have the same address.
  • Universal Consisting: The command station stores the consist information. The DCC system must support this type of consisting.
  • Advanced Consisting: The decoders store the consist information in CV 19- -which must be supported by the decoder, not the command station. 

I suspect the MRC system uses some form of Universal consisting.

An e-mail or phone call to them will clarify this question.

Each method has its pros and cons.

Different manufacturers handle consisting slightly different. I chose NCE because of the way it handles making and breaking consists.

Hope this helps.

"Uhh...I didn’t know it was 'impossible' I just made it work...sorry"

  • Member since
    December 2004
  • From: Bedford, MA, USA
  • 21,422 posts
Posted by MisterBeasley on Saturday, June 15, 2024 3:25 PM

I have an old Lenz system which still works well.  I have identified pairs of engines I run together and speed-matched those, generally using the CVs to get what I want.  Generally, these are a pair of Walthers geeps or a pair of Athearn F units.  They match up well.

I put the slightly faster engine in front if I can't get them close enough so all the couplers are being stretched, not pushed together.

I have found that the Bachmann "sound value" decoders do not support the momentum CVs, so I play with the Vstart, Vmid and Vhigh CVs to get rid of the jumpy jackrabbit starts of these engines.  Since those engines are a Mikado and a GG-1, there's not much danger getting either in a consist.

It takes an iron man to play with a toy iron horse. 

  • Member since
    December 2006
  • 1,845 posts
Posted by YoHo1975 on Saturday, June 22, 2024 12:15 AM

Basic, Universal and Advanced Consisting are DIGITRAX TERMS. They may not apply to other systems. Basic consisting is also not relevant to the DCC system since it's just setting the decoders to the same address.

MRC prodigy systems support CV19 consisting which they call simply consisting and sometimes advanced consisting. They also support in base station consisting (universal) Which they call "Old consisting."

 

NCE consisting is basically the combination of CV19 consisting with in station consisting.  

 

To the OP, as others have noted, you need to speed match the engines. Which means you have to adjust the decoders so that they both run at the same speed at the same throttle settings.

Typically the process is to determine which one is the slower of the 2 and then adjust the faster one so that it can only goes as fast as the slower one. Then adjust the settings for it's start and mid speeds.

  • Member since
    February 2020
  • 29 posts
Posted by know2go on Monday, July 1, 2024 3:40 PM

The most commonly used and most precise way to consist is to use speed tables defined for each of the decoders and track speed meter.

The speed meter will serve your objective link between decoders made by any manufacturer. The numbers published in decoder manuals are for guidance only as a few folks already mentioned.

Enjoy...

  • Member since
    October 2005
  • 1,045 posts
Posted by betamax on Monday, July 1, 2024 4:50 PM

YoHo1975

Basic, Universal and Advanced Consisting are DIGITRAX TERMS. They may not apply to other systems. Basic consisting is also not relevant to the DCC system since it's just setting the decoders to the same address.

 

Basic, Universal and Advanced are NMRA terms, not exclusive to Digitrax. Universal is another term for the command station dealing with consisting, where it keeps track of the addresses in the consist.

Digitrax calls theirs UniVersal, note the capitalisation. Their method is a blend of creating a consist within the command station, with the ability to write a consist address to CV19 if permitted, as per Advanced Consisting.

Basic means all the decoders in a consist have the same primary or extended address, and Advanced Consisting writes a unique address to each decoder in the consist using CV19. Advanced consist addresses live in the same space as the primary address (CV1). If CV19 is a non-zero address the primary and extended addresses are ignored. 

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!