Posted by CSX Robert on Tuesday, February 1, 2022 12:47 PM

pfenbach

I'm late to this discussion, but am interested as I am trying to use Tansey's Option A myself and wanted to find someone who had actually implemented it. The issue I am having is that if I choose position 1 on the rotary switch, for example, then the first resistor that receives power gets very hot - too hot to touch even. And the same thing happens as I move to other positions on the rotary, so it's not just one resistor. Since I can't believe that this is how this setup is supposed to function, I'm wondering if any of you that actually use Tansey's config could provide me with any guidance as to what I might be doing wrong. Thank you.

 

Yes, that first resistor has to dissipate ~0.257 watts (12 x 12 / 560), so I would expect it to get pretty hot.  0.257 watts may not sound like much, but consider that the typical through hole resistor that we often use in model railroading application is often only rated at 1/4 or 1/2 watt.

  • Member since
    January 2022
  • 3 posts
Posted by pfenbach on Tuesday, February 1, 2022 2:17 PM

Thanks for the response. I'm no electronics expert, but I am using the 560 ohms 1 watt resistor that Tansey recommends. Should a 1 watt resistor get that hot dissipating .25 watts?

  • Member since
    February 2007
  • From: Christiana, TN
  • 2,134 posts
Posted by CSX Robert on Tuesday, February 1, 2022 7:50 PM

pfenbach

Thanks for the response. I'm no electronics expert, but I am using the 560 ohms 1 watt resistor that Tansey recommends. Should a 1 watt resistor get that hot dissipating .25 watts?

 

Probably.

  • Member since
    January 2022
  • 3 posts
Posted by pfenbach on Wednesday, February 2, 2022 1:30 PM

It finally occurred to me to get out my multimeter and actually measure the voltage of my power supply. I was just using an old wall wart that stated the output as 12v DC, 400mA. Turns out it was putting out 17 volts. So using your formula: 17 x 17 / 560 is over .5 watts. Once I tried using a PS that actually measure 12v output, I got very little heat on the resistor. Thanks again for your responses.

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!