Posted by Rayd60 on Saturday, August 24, 2019 9:34 AM

A little help please.
I have a 15 x 10 HO layout twice around with two hidden reverse loops. Digitrax DCS240 and a DT500D throttle. Out of 10 Loco’s I have had to or will need to send back 7 for decoder issues. 4-BWL SD9’s & a few BWL steam and now a new Athearn SD40T.
The only locos that have not failed is a Scale Trains SD40-2 and a BWL 2-10-2 they run perfect and have been running for weeks.

These locos fail say in the first 10-mins out of the box most of these would still run fine in DC including sound just stop ruining in DCC and some like the SD9’s repeated this failure after a decoder reset. They run fine without a load then with 10 freight cars tie to any one loco they stop running after 10-mins. I did a reset on the DCS240 but then the Athearn failed no load. Most the address are readable but like the Athearn nothing. I write this because of the Athearn failure. BWL will allow a return on the SD9's I have not contacted Athearns yet, this just happen. I have not placed any of the previous repaired BWL locos on the rails.
I need to know what is going on before I place any new or repaired engines on the rails.
Is there any possibility that the DC240 is at fault? I can't think of a reason but I am reaching. 7 out of 10!
Thank you.
Ray D

  • Member since
    February 2002
  • From: Reading, PA
  • 30,002 posts
Posted by rrinker on Monday, August 26, 2019 3:13 PM

 What exactly is the failure? Do they move and then stop, move and then stop? That is often a sign that you have the same address selected more than once, and one is set to speed 0 and the otheris the one you are trying to control witht he throttle knob - so the loco will move, then stop, or suddenly change to a differen speed, then come back to the speed you have on the throttle in hand, over and over.

 Remember to clear each loco when you are done runnign it - set the speed to 0, turn off all functions, and then press Loco, and Exit. Now select the next loco you want to run. Repeat each time you switch to another loco.

 A reset of the DCS240 will clear this information, but you have to do the correct reset - which one did you do? Remember to check the OpSw section int he back of the manual - there are many web sites that come up if you google "digitrax command station reset" but man will be for the older DCS100 and some things have changed. The DCS240 instruction book will have the correct options to use.

                                     --Randy

 


Modeling the Reading Railroad in the 1950's

 

Visit my web site at www.readingeastpenn.com for construction updates, DCC Info, and more.

  • Member since
    February 2005
  • From: Vancouver Island, BC
  • 23,330 posts
Posted by selector on Monday, August 26, 2019 4:09 PM

The wide variety of locomotives, and their large number, suggest to me it's a problem with the system or the operator, perhaps both.  That many decoder failures is extremely unlikely.  I have never, in my 13 years on this forum and many others, seen another such claim of trouble.  So, I'm inclined to agree with Randy that something isn't right with the DB, possibly with the tether to the DT, something not seated in a slot inside the DT, or the tracks are not passing on reliable power to those locomotives for some reason.

  • Member since
    August 2019
  • 4 posts
Posted by Rayd60 on Monday, August 26, 2019 4:34 PM

Two of the 7 came back from BWL fixed. The 4-SD9's went out today to BWL for service. I followed both Digtrax and BWL reset instructions and no changes kepting them both in the loop. I set up a loop of track on a table and connected to it directly with a UT4 and no change. The Athearn SD40T is complety gone no responce in DC or DCC. I have not contacted them yet. Take note I have been runing Scaletrains SD40's for weeks no problem along with a BWL 2-10-2, solid runners. 

If BWL comes back with no problems on the 4) SD9's I will find a new hobby! The 4) SD9's are the real odd ball in my mind.

Thanks for the reply.

Ray D 

  • Member since
    December 2004
  • From: Bedford, MA, USA
  • 21,483 posts
Posted by MisterBeasley on Monday, August 26, 2019 5:13 PM

Were these decoders factory installed, local shop installed, or home installed?

Have you measured the track voltage?

Did you get these new, or pick them up second hand?

It takes an iron man to play with a toy iron horse. 

Moderator
  • Member since
    May 2009
  • From: Waukesha, WI
  • 1,764 posts
Posted by Steven Otte on Tuesday, August 27, 2019 8:42 AM

I had someone write in to Ask MR recently with a similarly perplexing problem. It turned out he was running his DCC system off a 15V power supply instead of a 12V one. Could that be your case?

--
Steven Otte, Model Railroader senior associate editor
sotte@kalmbach.com

  • Member since
    August 2019
  • 4 posts
Posted by Rayd60 on Tuesday, August 27, 2019 9:12 AM

The DCS240 requires a max of 24VDC I am feeding it with a regulated 22VDC @ 10A. It will operate properatly on lower voltage of 13VDC per Digitrax.

All of the locos are new out of the box bought from a BWL dealer, actualy two were purchase from BWL directly, from their remanufacture listing.

 

  • Member since
    April 2004
  • From: Ontario Canada
  • 3,574 posts
Posted by Mark R. on Tuesday, August 27, 2019 9:20 AM

Steven Otte

I had someone write in to Ask MR recently with a similarly perplexing problem. It turned out he was running his DCC system off a 15V power supply instead of a 12V one. Could that be your case?

 

Definitely check track voltage. That is also one of the main reasons why the Athearn engine bulbs never lasted very long - too high a track voltage translated into the onboard rectifiers supplying slightly more than 1.5 volts to the bulbs ending their lives pre-maturely.

Mark.

¡ uʍop ǝpısdn sı ǝɹnʇɐuƃıs ʎɯ 'dlǝɥ

  • Member since
    July 2007
  • From: Yorkton, Sk, Cnd
  • 441 posts
Posted by wvg_ca on Tuesday, August 27, 2019 10:38 AM

it seems likely that something simple is wrong, but you will need a multimeter and possible a rramp meter [or similar] to find out where it is ...  a good place to start is with the power supply used ...

i have been in the hobby for maybe a dozen years, and have yet to send a decoder back ..

  • Member since
    August 2019
  • 4 posts
Posted by Rayd60 on Tuesday, August 27, 2019 11:09 AM

Everything was walk through with Digitrax, first rate tec support by the way and BWL also great to work with. Everything was checked throughly and reset several times. As I repeat I have several locos that have been running just fine for months and continue to run just fine. 

Thanks.

  • Member since
    October 2006
  • From: Western, MA
  • 8,571 posts
Posted by richg1998 on Tuesday, August 27, 2019 11:53 AM

Yes, check track voltage. A RRampMeter is nice.

I use cheap Harbor Freight multimeters They show 13.6 volts AC on my NCE Power Cab but different meters might not show that. The DC supply is 13.9 vdc so close.

My Oscilloscope verifies. It shows peak to peak but I use math and it comes out close to what the meters show.

Rich

If you ever fall over in public, pick yourself up and say “sorry it’s been a while since I inhabited a body.” And just walk away.

  • Member since
    December 2015
  • From: Shenandoah Valley
  • 9,094 posts
Posted by BigDaddy on Tuesday, August 27, 2019 12:57 PM

If you are several volts out of wack, a Harbor Freight is good enough.

Henry

COB Potomac & Northern

Shenandoah Valley

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!