Bowser Challenger electrical problem?

1501 views
4 replies
1 rating 2 rating 3 rating 4 rating 5 rating
  • Member since
    December 2014
  • 443 posts
Bowser Challenger electrical problem?
Posted by Wolf359 on Saturday, September 15, 2018 2:13 PM

I have a Bowser 4-6-6-4 Challenger that has developed what I'm thinking might be an electrical issue, but I'm not sure. When I last ran it about a month ago, it was fine. I put it on my layout a few days ago and it started sparking at the rear tender wheels, (it has power pick ups on the tender and can't run without it) and when the sparking occurs, the motor sputters and cuts out at the same time. My track is clean, and so are the wheels, which I cleaned twice. Now it's gotten to the point where the locomotive won't even move. Does any one have any ideas on what could be causing this and how to fix it? P.S. It is standard DC and all of my other locos run fine on the layout.

Thank you.

  • Member since
    January 2004
  • From: Canada, eh?
  • 13,375 posts
Posted by doctorwayne on Saturday, September 15, 2018 2:59 PM

Try cleaning the mounting points where the tender trucks attach.  Even though this is a screw attachment, the mounting boss and the top surface of the truck bolsters oxidise over time, making electrical contact iffy.
This problem is common to brass steamers, too.

Wayne

  • Member since
    August 2003
  • From: Collinwood, Ohio, USA
  • 16,367 posts
Posted by gmpullman on Saturday, September 15, 2018 4:12 PM

Is it possible that one of the tender trucks inadvertantly got rotated 180°?

I looked at photos of the trucks on the "semi-Vanderbilt" tenders and it looks like there's plenty of room for them to have accidentally been rotated.

This is a good reason to have a volt and amp meter on your power supply. If it is indeed an "open" circuit as Wayne points out you'll see the amperage go to zero and the voltage spike. If a "short", as a wheel or truck not properly insulated, the amperage will spike while voltage will drop.

Worth a look, anyway...

Good Luck, Ed

  • Member since
    January 2009
  • From: Bakersfield, CA 93308
  • 6,526 posts
Posted by RR_Mel on Saturday, September 15, 2018 4:27 PM

If it has a Monogram Centipede Tender with a Bowser power kit (#150681) and you didn’t build it check the wiring to the brass cover strip holding the brass sleeves on the axles.  A wire could have come loose.  It’s been a long time since I installed the kit in my Centipede tender (1963) but I kinda remember soldering the pickup wire to the brass strip.
 
 
Scroll down to the  #150681 ELECTRIFICATION KIT
FOR MONOGRAM & CON COR 14-WHEEL TENDER Page 75
 
 
Mel
 
 
My Model Railroad   
 
Bakersfield, California
 
I'm beginning to realize that aging is not for wimps.
 
  • Member since
    December 2014
  • 443 posts
Posted by Wolf359 on Sunday, September 16, 2018 12:57 PM

doctorwayne

Try cleaning the mounting points where the tender trucks attach.  Even though this is a screw attachment, the mounting boss and the top surface of the truck bolsters oxidise over time, making electrical contact iffy.
This problem is common to brass steamers, too.

Wayne

 

 

Good news, it's working now! All I have to do now is make a few small adjustments to fine tune the ride of the trucks. Thank you Wayne for the suggestion to check the tender truck mounting points, as taking the trucks apart led me to the problem. They weren't oxidised however, it turned out to be a lot of gunk in the axel holes on the truck frames, (I'm not sure if this is the correct term), which surprised me as I try to keep everything as clean as possible. I guess I'll have to be more thorough. For any one else who may encounter this problem, it is a Kemtron AT-100 14 wheel HO centipede tender. I cleaned the above mentioned axel holes and axel tips on the wheels with Q-tips and Badger Just a Dab microbrushes dipped in 70% isopropyl alcohol. After that, I put it all back together and oiled it.

Thanks everyone for your help.

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!