Trains.com

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Will I have enough power or will I need to upgrade?

3201 views
14 replies
1 rating 2 rating 3 rating 4 rating 5 rating
  • Member since
    November 2011
  • From: Long Island
  • 130 posts
Will I have enough power or will I need to upgrade?
Posted by robkoz on Tuesday, July 18, 2017 9:29 PM

Currently running the NCE Power cab which in the begining only powered 1 main line, 56 feet of track around a room.

Now I currently have a few crossover tracks with 8 tortoise motors and a total of 3 main lines. 168 feet total. And 3-4 locos will be running.

Now that I'm almost done with the layout, will I need to upgrade? Is the basic 2 amp system enough for all this? Thanks

Moderator
  • Member since
    June 2003
  • From: Northeast OH
  • 17,249 posts
Posted by tstage on Tuesday, July 18, 2017 11:02 PM

Yea, I think your current mainline scenario might push your Power Cab - even if the Tortoises are being powered with a separate power supply.  You can either upgrade to the Smart Booster (SB5), or move up to the PH Pro.  The former would be the least expensive option; with the latter giving you an extra throttle with the upgrade.

Tom

https://tstage9.wixsite.com/nyc-modeling

Time...It marches on...without ever turning around to see if anyone is even keeping in step.

  • Member since
    July 2006
  • From: Bradford, Ontario
  • 15,797 posts
Posted by hon30critter on Wednesday, July 19, 2017 12:59 AM

I agree with Tom. You will be maxing out the Power Cab with four locomotives especially if they are sound equipped.

Dave

I'm just a dude with a bad back having a lot of fun with model trains, and finally building a layout!

  • Member since
    November 2011
  • From: Long Island
  • 130 posts
Posted by robkoz on Wednesday, July 19, 2017 3:44 AM

tstage

Yea, I think your current mainline scenario might push your Power Cab - even if the Tortoises are being powered with a separate power supply.  You can either upgrade to the Smart Booster (SB5), or move up to the PH Pro.  The former would be the least expensive option; with the latter giving you an extra throttle with the upgrade.

Tom

Is this the correct one?

https://www.modeltrainstuff.com/NCE-SB5-5-Amp-Smart-Booster-with-Power-Supply-p/nce-524027.htm

  • Member since
    March 2010
  • From: Sherwood Park, Alberta, Canada
  • 252 posts
Posted by CNR378 on Wednesday, July 19, 2017 11:51 AM

I have to disagree with the others. Your 2 amp system is more than enough to power what you described.  Even with sound locomotives you're probably pulling just an amp or less.

The best way to find out is to put an ammeter on the system to find out it's drawing.

Peter

Moderator
  • Member since
    June 2003
  • From: Northeast OH
  • 17,249 posts
Posted by tstage on Wednesday, July 19, 2017 1:42 PM

robkoz
tstage

Yea, I think your current mainline scenario might push your Power Cab - even if the Tortoises are being powered with a separate power supply.  You can either upgrade to the Smart Booster (SB5), or move up to the PH Pro.  The former would be the least expensive option; with the latter giving you an extra throttle with the upgrade.

Tom

Is this the correct one?

https://www.modeltrainstuff.com/NCE-SB5-5-Amp-Smart-Booster-with-Power-Supply-p/nce-524027.htm

robkoz,

Yes, that's the Smart Booster (SB5), which includes the needed power supply.  When you plug the Power Cab into the SB5, it automatically bypasses the 2A booster of the Power Cab and turns it into a PH Pro throttle.  So, the total output from the SB5 is 5A and not 5A plus 2A.

FYI: You'll still need the PCP panel to program locomotives.  And it needs to be completely isolated from the SB5.  In fact, you can program locomotives at your bench with just the Power Cab, PCP panel/power supply, and a piece of track.  When you're finished programming: Plug the Power Cab into the SB5 (i.e. either directly or daisy-chained to a UTP panel), put the locomotive back on the layout, and away you go.

Tom

https://tstage9.wixsite.com/nyc-modeling

Time...It marches on...without ever turning around to see if anyone is even keeping in step.

Moderator
  • Member since
    June 2003
  • From: Northeast OH
  • 17,249 posts
Posted by tstage on Wednesday, July 19, 2017 1:52 PM

CNR378

I have to disagree with the others. Your 2 amp system is more than enough to power what you described.  Even with sound locomotives you're probably pulling just an amp or less.

The best way to find out is to put an ammeter on the system to find out it's drawing.

Peter

Peter,

Correct me if I'm wrong but if you're pulling "just an amp or less" for two locomotives, you've already eaten up most of the capacity of your 2A Power Cab.  And what if each locomotive are double-headed?  And what if the Tortoises are also hooked up to track power?

Better to have extra capacity and not use it rather than push the envelope each time you're operating two or more locomotives simultaneously.  Kinda like playing 24W of sound through a 25W receiver.  Better to have 50W so that it sounds better and operates cooler.

Tom

https://tstage9.wixsite.com/nyc-modeling

Time...It marches on...without ever turning around to see if anyone is even keeping in step.

  • Member since
    December 2004
  • From: Bedford, MA, USA
  • 21,483 posts
Posted by MisterBeasley on Wednesday, July 19, 2017 6:16 PM

You may get by with 2 amps, but I would look ahead anyway and upgrade for more power.  That way you don't have to worry if you're pulling lighted passenger cars or running MU'd sound engines.

I run most of my Tortoise machines on a separate power supply, so they don't use track power, but if you're using stationary decoders you may need to account for that.  They only use a few milliamps each, but eventually even that adds up.

It takes an iron man to play with a toy iron horse. 

  • Member since
    July 2008
  • 1,206 posts
Posted by mfm37 on Wednesday, July 19, 2017 8:09 PM

Are you having problems now? If not, why upgrade now? Best way to find out is to try it. Amount of track means nothing because track does not consume power. Number of engines is the determining factor. I would suggest powering your switches with auxiliary power and not expensive DCC. They can get their commands from DCC and still work with analog DC or AC.

Martin Myers

  • Member since
    July 2017
  • 20 posts
Posted by Edsland on Wednesday, July 19, 2017 8:39 PM
With the NEC Power Cab you can show the amount of amps the layout is using on the controller display. Then you can see if your close to using all the available power.
  • Member since
    July 2006
  • From: Central Vermont
  • 4,565 posts
Posted by cowman on Wednesday, July 19, 2017 11:15 PM

I was running 3 sound locos with my NCE Power Cab, no problems.  Added another loco to doublehead one train.  Soon I had a problem.  Unit went back to NCE and they repaired it and said the cause was the fourth loco. 

If you plan to have more than three locos running at the same time, I'd upgrade or you will end up as I did.  Remember, it is the number of locos running, not the size of your layout that makes the difference.

I'd suggest the smart booster for its minimal cost.  If you want a 2nd throttle, get an O6, much less cost than upgrading to a Pro.  Of course there are a few other features with it that you may want to consider.

Good luck,

Richard

  • Member since
    November 2011
  • From: Long Island
  • 130 posts
Posted by robkoz on Thursday, July 20, 2017 7:47 AM

The 8 tortoise motors are controlled by an NCE 8switch which is powered by the track. Which is the best way to do this for this elevated layout. And since I will probably be running 4 or more locos with sound, I purchased the booster. It was a no brainer.

  • Member since
    December 2004
  • From: Bedford, MA, USA
  • 21,483 posts
Posted by MisterBeasley on Thursday, July 20, 2017 1:28 PM

When I first installed my Lenz DCC system, I powered it with an old train transformer.  The Lenz system is 5 amps, but the transformer I was using probably gave me not much more than 1 amp.  I started running into problems when I added a few old passenger cars with incandescent lights.

I replaced the transformer with an NCE 5-amp power supply designed for the job.  I think it cost me $35 dollars, and I have had no power issues in the years since I did that.

How much are the proposed solutions to the OP's question?  Mine was so cheap compared to other MR expenses that it was a no-brainer.

It takes an iron man to play with a toy iron horse. 

Moderator
  • Member since
    June 2003
  • From: Northeast OH
  • 17,249 posts
Posted by tstage on Thursday, July 20, 2017 1:34 PM

Rob,

If you ever want to move your Power Cab around to various spots of your layout for accessibility and viewing reasons, the UTP panels work very nicely for that.  All you need is a UTP panel and a 4-contact RJ-12 cable to connect it to the SB5.  Additional UTP panels can be daisy-chained from the back of the first UTP panel with additional cables.  It works quite well.

Tom

https://tstage9.wixsite.com/nyc-modeling

Time...It marches on...without ever turning around to see if anyone is even keeping in step.

Moderator
  • Member since
    June 2003
  • From: Northeast OH
  • 17,249 posts
Posted by tstage on Thursday, July 20, 2017 1:43 PM

MisterBeasley

How much are the proposed solutions to the OP's question?

MB Klein has the SB5 & power supply for $165.  The 5A PH Pro would be considerably more than that ($400, discounted).  That's the only options for upgrading the Power Cab.

Tom

https://tstage9.wixsite.com/nyc-modeling

Time...It marches on...without ever turning around to see if anyone is even keeping in step.

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!