Posted by hwolf on Saturday, December 26, 2015 9:41 AM

I just bought a Brandflackern 5921 Electronic flame

It call for an a 14-16 volt output from a power unit.

I have 17.3 coming from the power pack. Am I going to burn it out if I use this? 

I have 14.4 v coming from the DCC track. Can I connect to the Bus Wire?

Would that be better?

Harold

Moderator
  • Member since
    June 2003
  • From: Northeast OH
  • 17,249 posts
Posted by tstage on Saturday, December 26, 2015 9:56 AM

Harold,

I definitely would NOT power your electronic flame above the recommended range.  Otherwise, you might end up with a real flame on your hands. Whistling

Tom

https://tstage9.wixsite.com/nyc-modeling

Time...It marches on...without ever turning around to see if anyone is even keeping in step.

  • Member since
    July 2006
  • From: North Dakota
  • 9,592 posts
Posted by BroadwayLion on Saturday, December 26, 2015 10:09 AM

Never connect anything other than your tracks to the DCC system.

Buy a wall wart of the size you need, keeping in mind that not all wall warts are transformers, some are switching popwer supplies, and if you get one of these the thing that you ant to attach to it may not draw enought current to stableize the circuit. You man need to put a dummy load (a lamp for example) on the circuit.

 

ROAR

The Route of the Broadway Lion The Largest Subway Layout in North Dakota.

Here there be cats.                                LIONS with CAMERAS

  • Member since
    December 2004
  • From: Pa.
  • 3,361 posts
Posted by DigitalGriffin on Saturday, December 26, 2015 10:09 AM

tstage

Harold,

I definitely would NOT power your electronic flame above the recommended range.  Otherwise, you might end up with a real flame on your hands. Whistling

Tom

 

 

+1.  You Could hook up a couple of cheap diodes (about 10 cents each) in series.  Each one creates a .7V drop.  To if you hook 3 in a line together you would get a 2.1V drop.  But if your power supply is AC you'll need 3 pointed in each direction wired in parallel on 1 leg (wire from the power supply)

So 

->| is a diode with the silver band to the right

|<- is a diode with the silver band to the left

                                  /-->|-->|-->|\

Power supply wire --|                     +-----> to flicker board

                                  \|<--|<--|<--/

 

Don - Specializing in layout DC->DCC conversions

Modeling C&O transition era and steel industries There's Nothing Like Big Steam!

  • Member since
    October 2003
  • 571 posts
Posted by hwolf on Saturday, December 26, 2015 10:30 AM

I have seen in MR alot of times when something is hooked to the bus as long as you do not drop the voltage to much.  Why are you saying not you use the Bus?

Harold

  • Member since
    January 2009
  • From: Bakersfield, CA 93308
  • 6,526 posts
Posted by RR_Mel on Saturday, December 26, 2015 11:22 AM

hwolf

I have seen in MR alot of times when something is hooked to the bus as long as you do not drop the voltage to much.  Why are you saying not you use the Bus?

Harold

 

There are several reasons not to use your bus for accessories.  If you’re running DCC it robs current from your locomotives.  If your accessory is designed for DC operation the DCC output is not DC.  If you’re using a DC power pack the voltage depends on the throttle position.
 
If your accessory has a micro chip and it’s circuitry is not well filtered the DCC power can confuse the chip.
 
As stated above it’s not advisable to run accessories from track power.
 
 
 
Mel
 
Modeling the early to mid 1950s SP in HO scale since 1951
 
My Model Railroad   
 
Bakersfield, California
 
I'm beginning to realize that aging is not for wimps.
  • Member since
    October 2003
  • 571 posts
Posted by hwolf on Saturday, December 26, 2015 11:58 AM

Thanks Mel 

Good explaination.  I still am questioning if 17.3 v would really cause a problem.  Some experiance I have had with Warts is the voltage varies from wart to wart unles you go to the expense of the controled voltage.

Harold

  • Member since
    January 2009
  • From: Bakersfield, CA 93308
  • 6,526 posts
Posted by RR_Mel on Saturday, December 26, 2015 12:42 PM

hwolf

Thanks Mel 

Good explaination.  I still am questioning if 17.3 v would really cause a problem.  Some experiance I have had with Warts is the voltage varies from wart to wart unles you go to the expense of the controled voltage.

Harold

 

I wouldn’t use any voltage higher than what the manufacturer specs say, before I retired we called that type of experimenting “tune for maximum smoke”.  Once the smoke escapes it’s useless.
 
 
You can’t put the smoke back in and expect it to work!
 
 
 
Mel
 
Modeling the early to mid 1950s SP in HO scale since 1951
 
My Model Railroad   
 
Bakersfield, California
 
I'm beginning to realize that aging is not for wimps.
  • Member since
    October 2003
  • 571 posts
Posted by hwolf on Sunday, December 27, 2015 8:25 AM

I have a Wall Wart that is putting out the proper voltage.  It is currently connected to an arc welding animaton.  

Am I correct that if I connect the flame to the same Wall Wart I would still get the proper voltage for both?

Harold

  • Member since
    January 2009
  • From: Bakersfield, CA 93308
  • 6,526 posts
Posted by RR_Mel on Sunday, December 27, 2015 9:45 AM

Check the back (plug side) of the wall wart for the voltage and current rating, most are between .3 to 1 amp (or 300 ma to 1000 ma).  I doubt if either of your goodies draw more than a few milliamps so you should be good to go.
 
 
 
Mel
 
Modeling the early to mid 1950s SP in HO scale since 1951
 
My Model Railroad   
 
Bakersfield, California
 
I'm beginning to realize that aging is not for wimps.

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!