Early MRC sound decoder programming?

4249 views
10 replies
1 rating 2 rating 3 rating 4 rating 5 rating
  • Member since
    January 2005
  • From: Winnipeg Canada
  • 1,637 posts
Early MRC sound decoder programming?
Posted by Blind Bruce on Tuesday, April 21, 2015 9:41 AM

I don't think the early MRC sound decoders will read back the CV numbers. I also do not think they will program on the programming track. That leaves program on the main. I want to have CV29 with a value of 34 an I don't know if that is the value that is already in there. I managed to set other locos but this one is confusing me. NCE power pro system. What is the procedure to make sure I have #34 in CV29?

73

Bruce in the Peg

  • Member since
    July 2003
  • From: Sierra Vista, Arizona
  • 13,757 posts
Posted by cacole on Tuesday, April 21, 2015 10:30 AM

If the decoder offers no readback, the only thing you can do is program CV29 with a value of 34 using main line programming, and hope for the best.

Early MRC sound decoders were known to be problematic.

  • Member since
    January 2005
  • From: Winnipeg Canada
  • 1,637 posts
Posted by Blind Bruce on Tuesday, April 21, 2015 11:00 AM

Thanks Cacole. I did as you say and hope for the best. All functions still work as they did before "programming"

73

Bruce in the Peg

  • Member since
    December 2004
  • From: Pa.
  • 3,361 posts
Posted by DigitalGriffin on Tuesday, April 21, 2015 12:27 PM

A way a command station knows a command took is by a current draw on the track.  When the motor moves, there is a significant increase in the current draw and the command station picks up on this.  (This is why there are tiny movements everytime we program our trains).  That said, the MRC decoders take too long a time from the program command till the motor response, and the command station gets "tired of waiting" for that current pulse and goes, "It must have failed"  But the commands DO TAKE.  It's just the older MRC decoders didn't responsd in time.

Don - Specializing in layout DC->DCC conversions

Modeling C&O transition era and steel industries There's Nothing Like Big Steam!

  • Member since
    November 2013
  • 2,775 posts
Posted by snjroy on Wednesday, April 22, 2015 4:26 PM
Hi. The Pdf manual (available on Athearn-Roundhouse Website) suggests that there is no CV29 on this decoder. Check it out and see what are your options. Good luck!

Simon





  • Member since
    February 2008
  • 8,879 posts
Posted by maxman on Wednesday, April 22, 2015 5:49 PM

snjroy
Hi. The Pdf manual (available on Athearn-Roundhouse Website) suggests that there is no CV29 on this decoder. Check it out and see what are your options. Good luck!

Simon

 

Curious to see a link to this manual.  So far as I know every DCC decoder has a CV 29.

  • Member since
    November 2013
  • 2,775 posts
Posted by snjroy on Wednesday, April 22, 2015 7:46 PM
http://www.athearn.com/Products/Default.aspx?ProdID=RND84535

See link at the bottom. I've used this manual for my own Roundhouse 4-4-0...
  • Member since
    January 2005
  • From: Winnipeg Canada
  • 1,637 posts
Posted by Blind Bruce on Wednesday, April 22, 2015 8:00 PM

The manual says to test the loco on DC. Therefore it is a dual mode decoder. The DC section is probably not able to be turned off.

73

Bruce in the Peg

  • Member since
    January 2015
  • 257 posts
Posted by RR Baron on Wednesday, April 22, 2015 8:29 PM

snjroy
Hi. The Pdf manual (available on Athearn-Roundhouse Website) suggests that there is no CV29 on this decoder. Check it out and see what are your options. Good luck!

Simon

 

 

 

Look again, the 76141.1 09/15/06 manual does include CV 29.

 

Also notice this dual mode MRC decoder with sound does not support the CV read back feature.

 

 

  • Member since
    April 2004
  • From: Ontario Canada
  • 3,574 posts
Posted by Mark R. on Wednesday, April 22, 2015 8:32 PM

snjroy
http://www.athearn.com/Products/Default.aspx?ProdID=RND84535

See link at the bottom. I've used this manual for my own Roundhouse 4-4-0...
 

Not sure what you are looking at, but it clearly shows shows CV29 in the table with a default value of 2. To be NMRA compliant, a decoder must support CV29 as basic configuration.

Mark.

¡ uʍop ǝpısdn sı ǝɹnʇɐuƃıs ʎɯ 'dlǝɥ

  • Member since
    November 2013
  • 2,775 posts
Posted by snjroy on Wednesday, April 22, 2015 8:44 PM

Yes, I see that now! (CVs are not in order on the list). I also noticed that in the bottom of the page, it says that there is no read back feature. 

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!