Posted by jeromeandwestern on Saturday, February 7, 2015 6:59 PM

Hi this is my first post (probably not my last). First of all I would like to thank all of you that contribute to this forum. I have been stealing information from here for months now and my guilt finally got the better of me so I sacrificed two podcast to joinBig Smile I am almost to the wiring stage of my second layout after taking a short twelve year break. It is a 24 x 17 foot double track dog bone. The inside track is isolated from the outside. I'm trying to KISS. I've laid the track for common rail two cab. Of the eighty plus locks I own three are sound and one (so far) is d c c. I Recently bought a Bachmaan e-mail command to tinker with sound. My question is what would be the best way to incorporate this into the layout so I don't have to constantly disconnect it? Can the ground from this be tied to the ground from a d c power pack? I read someone say it could be tied to one cab via a s p d t switch? Any help would be welcome. And thanks again to all of you. Wayne

  • Member since
    February 2015
  • 24 posts
Posted by jeromeandwestern on Monday, February 9, 2015 9:44 AM

jeromeandwestern

Hi this is my first post (probably not my last). First of all I would like to thank all of you that contribute to this forum. I have been stealing information from here for months now and my guilt finally got the better of me so I sacrificed two podcast to joinBig Smile I am almost to the wiring stage of my second layout after taking a short twelve year break. It is a 24 x 17 foot double track dog bone. The inside track is isolated from the outside. I'm trying to KISS. I've laid the track for common rail two cab. Of the eighty plus locks I own three are sound and one (so far) is d c c. I Recently bought a Bachmaan e-mail command to tinker with sound. My question is what would be the best way to incorporate this into the layout so I don't have to constantly disconnect it? Can the ground from this be tied to the ground from a d c power pack? I read someone say it could be tied to one cab via a s p d t switch? Any help would be welcome. And thanks again to all of you. Wayne

 

This is what I get for typing on a kindle. Podcast should have been box cars locks should have been locos. Now you see why I'm a dcc dummy.

  • Member since
    February 2015
  • 24 posts
Posted by jeromeandwestern on Monday, February 9, 2015 10:00 AM

jeromeandwestern

Hi this is my first post (probably not my last). First of all I would like to thank all of you that contribute to this forum. I have been stealing information from here for months now and my guilt finally got the better of me so I sacrificed two podcast to joinBig Smile I am almost to the wiring stage of my second layout after taking a short twelve year break. It is a 24 x 17 foot double track dog bone. The inside track is isolated from the outside. I'm trying to KISS. I've laid the track for common rail two cab. Of the eighty plus locks I own three are sound and one (so far) is d c c. I Recently bought a Bachmaan e-mail command to tinker with sound. My question is what would be the best way to incorporate this into the layout so I don't have to constantly disconnect it? Can the ground from this be tied to the ground from a d c power pack? I read someone say it could be tied to one cab via a s p d t switch? Any help would be welcome. And thanks again to all of you. Wayne

 

e mail command should have been ez command. Grrrrr

 

  • Member since
    February 2002
  • From: Reading, PA
  • 30,002 posts
Posted by rrinker on Monday, February 9, 2015 10:21 AM

 What you want is a double pole double throw switch with a center off position. You connec the DCC to one side, and your DC power pack to the other side. The middle terminals go to the layout. This way, you can only connect the DC power pack OR the DCC unit, never both at the same time, which is how you fry components.

                 --Randy


Modeling the Reading Railroad in the 1950's

 

Visit my web site at www.readingeastpenn.com for construction updates, DCC Info, and more.

  • Member since
    October 2006
  • From: Western, MA
  • 8,571 posts
Posted by richg1998 on Monday, February 9, 2015 12:51 PM

Do you have the Bachmann EZ Command or Bachmann Dynamis? Big difference in capabilities.

If you inadvertently connect the DC pack to the DCC controller, you will most probably smoke the DCC system. Others have done it. Happened to our club with a 5 amp system.

 

Rich

If you ever fall over in public, pick yourself up and say “sorry it’s been a while since I inhabited a body.” And just walk away.

  • Member since
    September 2003
  • 10,582 posts
Posted by mlehman on Monday, February 9, 2015 2:24 PM

Yep, a DPDT Center-Off switch is the best method if you want to run both.

You mentioned an unconnected loop. So long as there is no physical connection by rail or otherwise between it and the rest of the layout, you could run DC on one and DCC on the other at the same time. But NEVER let them come together or, as has been already noted, the magic DCC mojo smoke will escape.

Now if everything is wired together with common rail, you have a problem, because there already IS a connection. Sometimes with DCC, common rail can cause problem even with pure DCC systems. Don't know how far along you are with wiring, but you may want to look into common rail issues with DCC. I think it can work, but there are some things that need to be adjusted if used with DCC. I dunno, because I never did things that way, so YMMV

Mike Lehman

Urbana, IL

  • Member since
    February 2015
  • 24 posts
Posted by jeromeandwestern on Monday, February 9, 2015 4:05 PM

Hi, Thanks for all the replies thus far. Yes the loops are separated d c c was part of the reason. The other reason is there are some kids in the the neighborhood that love trains and I'm trying to make operation as simple as possible. Normally I use d p d t switches for the blocks track wired to one side an block lights to the other. Would the wiring for the e z command be similar? Wayne

  • Member since
    December 2011
  • From: Northern Minnesota
  • 2,774 posts
Posted by NP2626 on Monday, February 9, 2015 5:57 PM

What your wanting to do is exactly what I did in 2002.  I can be of help, if you need it, PM me. 

NP 2626 "Northern Pacific, really terrific"

Northern Pacific Railway Historical Association:  http://www.nprha.org/

  • Member since
    February 2015
  • 24 posts
Posted by jeromeandwestern on Tuesday, February 10, 2015 3:27 AM

Just went with the ez command. I didn't want to spend a lot of $$$ till I was sure what I wanted to do. Waynr

  • Member since
    February 2015
  • 24 posts
Posted by jeromeandwestern on Tuesday, February 10, 2015 4:47 AM

Hi, I'll do that when I get a little further along. I'm a damned old truck driver so right now I only get to play with my toys about once a month. I'll be home next week all week working on track work. I've been adding extra drop lines as I go along to try and make things a little more reliable. The sound locos seem to do just fine on dc or dcc so far, but at this point all my wiring is temporary. I haven't got my control panel built yet. After 12 years off I was really surprised how much I had to relearn. Wayne

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!