Apex & Hypotenuse Controller issue

1473 views
2 replies
1 rating 2 rating 3 rating 4 rating 5 rating
  • Member since
    March 2014
  • 2 posts
Apex & Hypotenuse Controller issue
Posted by TwoBears on Saturday, March 15, 2014 7:00 AM

I built the Atlas Apex & Hypotenuse from the Big Book but the B cab only works in the reversing section powered by XY feeders from Atlas Controller (220). The A cab works perfectly as intended around the entire layout, smoothly through reverse loop and both Controller direction switches work for cab A. The B cab has no power outside of the XY gapped section.  I re-traced all wires and re-checked all insulators with diagram. With cab A working perfectly, i think i have it wired correctly and suspect the Controller. Is that possible or am i overlooking something? Any help is much appreciated!

  • Member since
    February 2002
  • From: Reading, PA
  • 30,002 posts
Posted by rrinker on Sunday, March 16, 2014 11:02 AM

 If you are certain you have everything wired correctly, it's possible that the Controller is bad. With everything disconnected from it, you cna try testing continuity through from one of the Cab B terminalks on the left to the bottom two terminals on the right. Which one has continuity at a given time will depend on the position of the Cab B reversing switch, but in some combo there should be continuity from each of the Cab B input terminals to one of the outputs on the right. A broken trace in here would explain why Cab B works int eh reversing section and not in any other area. If this does check out and there is continuity, then there's a wiring problem elsewhere. The bottom terminal on the right of the Controller needs to be connected to the bottom terminal on each Selector.

              --Randy

 


Modeling the Reading Railroad in the 1950's

 

Visit my web site at www.readingeastpenn.com for construction updates, DCC Info, and more.

  • Member since
    March 2014
  • 2 posts
Posted by TwoBears on Sunday, March 16, 2014 6:42 PM

Thanks Randy, I didn't think of that, couldn't figure out how to test the controller.

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!