Trains.com

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

atlas master dcc

2527 views
12 replies
1 rating 2 rating 3 rating 4 rating 5 rating
  • Member since
    June 2013
  • 5 posts
atlas master dcc
Posted by CSXfan1995 on Friday, July 5, 2013 5:37 PM

does anyone know what type of snubber should be used on an atlas master dcc system?

  • Member since
    April 2004
  • From: Ontario Canada
  • 3,574 posts
Posted by Mark R. on Friday, July 5, 2013 6:36 PM

What trouble are you having that you think you need a snubber ?

Mark.

¡ uʍop ǝpısdn sı ǝɹnʇɐuƃıs ʎɯ 'dlǝɥ

  • Member since
    June 2013
  • 5 posts
Posted by CSXfan1995 on Friday, July 5, 2013 9:03 PM

its distorting signals to my dcc sound equipped engines, i won't have any power applied to a locomotive and it will move for short distance, or the bell or horn will sound even when i haven't even hit function 1 or 2, i'm not sure if i need a snubber that can help keep my system from distorting the dcc signals or it is in my decoder

  • Member since
    July 2006
  • 3,312 posts
Posted by locoi1sa on Friday, July 5, 2013 9:20 PM

 I pray every day I break even, Cause I can really use the money!

 I started with nothing and still have most of it left!

  • Member since
    April 2004
  • From: Ontario Canada
  • 3,574 posts
Posted by Mark R. on Friday, July 5, 2013 9:36 PM

Nice link, but is the original poster having any of these problems ? I'm still using an Atlas Master Controller on a 24 X 25 foot layout running three wireless throttles and have never experienced any of these problems requiring a snubber. (?)

It's really no different than those recommendations you need to have feeder wires to EVERY piece of track. Sure, it doesn't hurt, but it's not necessary either - there reaches a point of paranoid overkill. If you are noticing problems, then look into the corrections.

If everything is working as it should and you are experiencing no problems, why fix it ?

"They" say not to loop the buss wires back to where they start .... I did that to mine twelve years ago, not knowing that it was recommended not to .... it's still looped back to itself twelve years later and has never caused any problem, so I never "fixed" it.

Mark.

¡ uʍop ǝpısdn sı ǝɹnʇɐuƃıs ʎɯ 'dlǝɥ

  • Member since
    July 2006
  • 3,312 posts
Posted by locoi1sa on Friday, July 5, 2013 9:49 PM

CSX.

 Look at this link too.

http://www.wiringfordcc.com/dcc_waveforms.htm

       Pete

 I pray every day I break even, Cause I can really use the money!

 I started with nothing and still have most of it left!

  • Member since
    February 2008
  • 8,879 posts
Posted by maxman on Friday, July 5, 2013 9:52 PM

CSXfan1995

its distorting signals to my dcc sound equipped engines, i won't have any power applied to a locomotive and it will move for short distance, or the bell or horn will sound even when i haven't even hit function 1 or 2, i'm not sure if i need a snubber that can help keep my system from distorting the dcc signals or it is in my decoder

 
Have you adjusted CV 29 such that the locos run on DCC only?
  • Member since
    September 2004
  • From: Dearborn Station
  • 24,281 posts
Posted by richhotrain on Saturday, July 6, 2013 5:18 AM

Mark R.

Nice link, but is the original poster having any of these problems ? I'm still using an Atlas Master Controller on a 24 X 25 foot layout running three wireless throttles and have never experienced any of these problems requiring a snubber. (?)

It's really no different than those recommendations you need to have feeder wires to EVERY piece of track. Sure, it doesn't hurt, but it's not necessary either - there reaches a point of paranoid overkill. If you are noticing problems, then look into the corrections.

If everything is working as it should and you are experiencing no problems, why fix it ?

"They" say not to loop the buss wires back to where they start .... I did that to mine twelve years ago, not knowing that it was recommended not to .... it's still looped back to itself twelve years later and has never caused any problem, so I never "fixed" it.

Mark.

Snubbers are so easy to build and install, so, why not just do it?   See if it solves the problem.  Who knows what conditions exist in the OP's layout room that may be interfering with flawless performance?

Rich

Alton Junction

  • Member since
    October 2005
  • 1,047 posts
Posted by betamax on Saturday, July 6, 2013 5:56 AM

CSXfan1995

its distorting signals to my dcc sound equipped engines, i won't have any power applied to a locomotive and it will move for short distance, or the bell or horn will sound even when i haven't even hit function 1 or 2, i'm not sure if i need a snubber that can help keep my system from distorting the dcc signals or it is in my decoder

You know it is distorted how?  Have you used a scope to see what is happening?

Very likely there is another problem, and adding a termination isn't going to solve that. Some manufacturers do not recommend them either.

Highly unlikely that a distorted signal would be interpreted as a valid DCC packet.  The odds of it happening are very unlikely. 

Do you have the decoders set for DCC only? Do you have analog capability which may be active? It is also possible the decoder has problems or the memory has become corrupted.

  • Member since
    June 2013
  • 5 posts
Posted by CSXfan1995 on Saturday, July 6, 2013 7:32 AM

well since all of my locomotives are having the same problem, I figure it cannot be that all of my decoders have gone bad. There is a definite spike in voltage during a typical operating session. I use to have an NCE  system and never had the problems I am having with the Atlas master system 

  • Member since
    July 2003
  • From: Sierra Vista, Arizona
  • 13,757 posts
Posted by cacole on Saturday, July 6, 2013 8:58 AM

CSXfan1995

well since all of my locomotives are having the same problem, I figure it cannot be that all of my decoders have gone bad. There is a definite spike in voltage during a typical operating session. I use to have an NCE  system and never had the problems I am having with the Atlas master system 

This tends to indicate to me that something is faulty with your Atlas Master system or there is something in or near your layout that is causing electrical problems not related to DCC.
I doubt that a snubber is going to help matters, but connecting your Atlas Master to a high-quality surge suppressor may solve the problem.  Also make absolutely sure your Atlas Master is connected to a properly grounded electrical outlet.
  • Member since
    April 2004
  • From: Ontario Canada
  • 3,574 posts
Posted by Mark R. on Saturday, July 6, 2013 11:22 AM

Something else too - I had forgotten I had done this it was so long ago ....

The Atlas Commander track voltage runs on the high side to what is considered normal. You really should lower the output voltage. Prior to doing this, I did have a number of strange things happen during an operating session like runaways and functions turning themselves on and off . Atlas has a how-to on their site ....

http://www.atlasrr.com/voltage.htm

Without lowering the voltage, the track voltage from the Commander will be pushing 18 volts - which is too high. A voltage spike on 18 volts will be well beyond what most decoders can tolerate. You can still try the snubber if you want - it won't hurt anything, but you really do need to lower the output voltage.

Mark.

¡ uʍop ǝpısdn sı ǝɹnʇɐuƃıs ʎɯ 'dlǝɥ

  • Member since
    June 2013
  • 5 posts
Posted by CSXfan1995 on Saturday, July 6, 2013 6:05 PM

thanks for all of the input and links! it has made my trains operate much better!

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!