Trains.com

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

DC hand held throttles

12817 views
12 replies
1 rating 2 rating 3 rating 4 rating 5 rating
  • Member since
    November 2010
  • 26 posts
DC hand held throttles
Posted by Balloon Dude on Tuesday, February 12, 2013 7:39 PM

Hello all. I am wondering if anyone knows where I can buy handheld DC throttles that I can hook up to MRC Railpower 1370 power packs.  Preferably corded.   I am finding out that most suppliers/manufacturers have discontinued making them.  Perhaps someone who has converted to DCC?

Thanks,

 Matt

  • Member since
    March 2007
  • From: South Carolina
  • 1,719 posts
Posted by Train Modeler on Wednesday, February 13, 2013 10:06 AM

This is the source for my old DC hand held equipment before going to DCC.   I'm not a fan of MRC beyond a basic level.    Very good quality. 

http://www.thegmlenterprises.com/index.html

Richard

  • Member since
    January 2002
  • From: Hilliard, Ohio
  • 1,139 posts
Posted by chatanuga on Wednesday, February 13, 2013 2:26 PM

I have two of these on my layout.  http://www3.sympatico.ca/kstapleton3/851.HTM

I have four MRC Tech II Locomotion 2500 power packs on my layout.  On the two that I primarily use for yard switching and traffic in and out of the staging yards, I have these hooked up.  They come with four wires.  Two go to the AC terminals on the power pack, and two go to the track.

When I initially set up my layout, I had a six-cab power bus going around the layout to each of the control panels to switch the power between cabs for each block.  With the walkaround throttles, I disconnected two cabs from the bus and then created a second bus for the AC power from the two power packs.  That bus goes out to the main yard and the two staging yards.  There, I installed plugs like I'd used between my layout sections to bring the AC power through the plugs, to the throttle, back through the plugs, and to the original cab bus, allowing me to unplug a walkaround throttle (with the train stopped) and use it elsewhere on the layout.

They've worked flawlessly, and being about to be close to where I'm working in the yard and not having to run back and forth between my train and the power pack is a huge plus.

Kevin

  • Member since
    January 2013
  • 70 posts
Posted by dschroeder83 on Thursday, February 14, 2013 8:53 PM
I just purchased the throttle in the above post. Shoot Ken an email and ask him to call if you have questions on it. Super nice guy, quick shipping as well. Can't wait to try mine out when I get the track finished

http://www3.sympatico.ca/kstapleton3/851.HTM
  • Member since
    November 2010
  • 26 posts
Posted by Balloon Dude on Friday, February 15, 2013 7:31 AM

Thanks for the info Kevin.  My layout is a 4x8 with blocks for dual cab.  Would I have to hook the hand held up to all the blocks?

Matt

  • Member since
    November 2010
  • 26 posts
Posted by Balloon Dude on Friday, February 15, 2013 7:35 AM

Oops, I forgot to thank Richard and dschroeder83 for their input.  Thank you!  Richard, I was not able to open the link that you had posted.

Matt

  • Member since
    October 2005
  • From: Detroit, Michigan
  • 2,284 posts
Posted by Soo Line fan on Friday, February 15, 2013 9:01 AM

Jim

  • Member since
    January 2002
  • From: Hilliard, Ohio
  • 1,139 posts
Posted by chatanuga on Saturday, February 16, 2013 12:08 PM

Balloon Dude

Thanks for the info Kevin.  My layout is a 4x8 with blocks for dual cab.  Would I have to hook the hand held up to all the blocks?

Matt

No, if you have power going out from your power pack/transformer, the hand-held throttle goes between your wires going out to the layout and the power pack.  Also, it connects to the AC connectors on your power pack, and not the track power.

On my layout, I already had the four cabs wired directly into my "power bus" (variable DC track power) going around the layout to the control panels.  For the cabs that I converted to walkaround, I removed the connections between the two power packs and the bus.  I then created a new bus to connect the AC connections for those two cabs into.  I ran that bus to the three locations where I wanted to plug in the walkaround throttles.  That keeps the AC power separate from the DC power that the trains run on since AC power can damage the motors from what I've read/heard.  The AC power then goes down the cord into the walkaround throttle where it is converted into the variable DC power that goes back down the cord and into the power bus and the track.

Kevin

  • Member since
    July 2006
  • From: Central Vermont
  • 4,565 posts
Posted by cowman on Saturday, February 16, 2013 10:09 PM

Matt,

I have a Tech 4, 350 with a Tech 4 Walkaround Throttle.  Don't know if that would fit your power packs or not.  Found a second one on ebay at a reasonable price.

Good luck,

Richard

  • Member since
    November 2010
  • 26 posts
Posted by Balloon Dude on Sunday, February 17, 2013 5:22 PM

Cowman,

I don't know if that would work on a Railmaster 1370.  Anyone out there have an answer?

 

  • Member since
    October 2005
  • From: Detroit, Michigan
  • 2,284 posts
Posted by Soo Line fan on Sunday, February 17, 2013 6:08 PM

The 350 hand held will not work with the 1370, only with the 350 power pack.

Jim

  • Member since
    November 2002
  • From: Colorado
  • 4,075 posts
Posted by fwright on Monday, February 18, 2013 8:36 AM

Balloon Dude

Hello all. I am wondering if anyone knows where I can buy handheld DC throttles that I can hook up to MRC Railpower 1370 power packs.  Preferably corded.   I am finding out that most suppliers/manufacturers have discontinued making them.  Perhaps someone who has converted to DCC?

Matt

The Railpower 1370 power pack is at the lower end of the MRC power pack lineup.  As such, there was never a specific remote made for it.  So what you have to do is use the 1370 as the power supply for a handheld DC throttle.  This may sound limiting, but its not.  You can use any complete, generic DC throttle attached to the the AC outputs of the 1370.

MRC made a couple of generic handheld throttles years ago - Model 44 and its successors.  Some of those required DC input, and some worked off AC.  I had one.  I wasn't impressed.  It had external screw connectors on the handheld, which seemed like a poor way to attach any cord.  And it was a rheostat inside, not a transistor throttle, which meant poorer control of modern low current locomotives.

The alternative with MRC is to replace your 1370s with up-line units that have available handheld throttles.  The MRC Tech 4 350, ControlMaster 20, and Tech 6 are all examples of such setups.  The Tech 6 can also run some DCC locomotives.

A couple of other posters have given you suggestions for currently available DC handheld throttles.  A DC throttle is a relatively simple device, and easy to build yourself.  There are circuits and kits at http://www.awrr.com/throttle.html and http://home.cogeco.ca/~rpaisley4/Throttles.html.  Here is an example of a very simple handheld DC throttle I built from a circuit in Model Railroader.  I used an old AHM power pack with a broken rheostat for the AC power supply.  The cord is a coiled, corded telephone handset cord.  The cases came from Radio Shack, as did the 4 pole plug I used.  I moved the rectifier, power transistor and heat sink, and direction relay to under the layout to keep train current out of the handset cord.  Cost of all components was less than $20, even at Radio Shark prices.  Yes, I still use this throttle today.

my thoughts, your choices

Fred W

  • Member since
    November 2010
  • 26 posts
Posted by Balloon Dude on Friday, February 22, 2013 6:22 PM

Thank you all for all your help and information.  Unfortunately I never received any response from the mfrs.  But, with all your guidance I was able to find someone who will be able to make one for me.

Thanks again for all of your help.  I do appreciate it.

Matt

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!