Posted by Anonymous on Saturday, May 5, 2012 7:51 PM

Sorry to clog up the website, but wanted to make this a separate post for quick response.

The Walthers Cornerstone turntable calls for optimum of 16 VDC 500 mA.  Will take 12V to not more than 18 V and will run on AC voltage supplies.

My electronics supplier has these close choices in switching power supplies (those are the units that put out the actual voltage they state):

1. 15 VDC 1.3 amp (1300 mA)

2. 18 VDC 1.1 amp

3. 12 VDC .6 amp

4. 12 VDC 1.2 or 1.6 amp

Which is the best choice?

 

  • Member since
    February 2002
  • From: Reading, PA
  • 30,002 posts
Posted by rrinker on Saturday, May 5, 2012 8:45 PM

#1, #2 is also acceptable.

 

              --Randy


Modeling the Reading Railroad in the 1950's

 

Visit my web site at www.readingeastpenn.com for construction updates, DCC Info, and more.

  • Member since
    September 2004
  • From: Dearborn Station
  • 24,281 posts
Posted by richhotrain on Sunday, May 6, 2012 6:32 AM

Hey, what do I know, but wouldn't #4 work too?

Rich

Alton Junction

  • Member since
    March 2010
  • From: Sherwood Park, Alberta, Canada
  • 252 posts
Posted by CNR378 on Sunday, May 6, 2012 7:36 AM

richhotrain

Hey, what do I know, but wouldn't #4 work too?

Rich

Actually they would all work BUT #1 is closer to the optimum mentioned and would be the best choice. A 1/2 amp fuse could be added if a person was concerned about possible over current draw.

Peter

  • Member since
    July 2009
  • From: lavale, md
  • 4,678 posts
Posted by gregc on Sunday, May 6, 2012 11:17 AM

i'd say that anything over 500 ma is unnecessary  (that is more $$)

have you considered trying an unused wall supply that might be lying around ($$0),  anything over 12V and 500 ma.

greg - Philadelphia & Reading / Reading

  • Member since
    February 2002
  • From: Reading, PA
  • 30,002 posts
Posted by rrinker on Sunday, May 6, 2012 11:48 AM

richhotrain

Hey, what do I know, but wouldn't #4 work too?

Rich

Well theoretically they would all work, although #3 is awfully close to the limit and if unregulated might drop below 12V whent he power draw gts near the max, such as when the bridge starts moving with a heavy loco on it. #1 is just the best since it's smack dead in the middle voltage wise, and has plenty of current capacity.

Guess I misread, I was under the impression that these were choices the OP already had and wanted to know which one was best, not a list of options to buy. With luck something close would be just laying around although a lot of smaller devices that leave working wall warts behind when they expire use less current, but worth checking before spending money.

                 --Randy

 


Modeling the Reading Railroad in the 1950's

 

Visit my web site at www.readingeastpenn.com for construction updates, DCC Info, and more.

  • Member since
    April 2003
  • 305,205 posts
Posted by Anonymous on Sunday, May 6, 2012 12:49 PM

rrinker

 

Guess I misread, I was under the impression that these were choices the OP already had and wanted to know which one was best, not a list of options to buy. With luck something close would be just laying around although a lot of smaller devices that leave working wall warts behind when they expire use less current, but worth checking before spending money.

                 --Randy

Well I do have several 12VAC around of various amperages, and can pick up something with more voltage in the junk store in town for a couple bucks.

But since I found out those Class II power supplies actually put out  variable amounts of voltage I have only gone with switching power supplies for my use lately.....they cost only $5 more or so than the unregulated supplies and I can be sure what I am getting.

With my meter I have found 9V units that make anything from 12 to 17V available and using a Class II 12 V might just allow more than 20V through....no?....although I have one in my hand now that reads 14.2 V and is 1 amp.....maybe that is good enough and I am being too cautious.

  • Member since
    February 2002
  • From: Reading, PA
  • 30,002 posts
Posted by rrinker on Sunday, May 6, 2012 1:44 PM

 The one reading 14.4V no load shouldn't drop below 12V at the half load which is the max the turntable will apply to it (rated for 1 amp, turntable draw max 500ma). Over the voltage limit is uaulyl the greater concern, as far as risk of damage. Slightly under may result in erratic operation but rarely actually causes permanent damage. Go ahead and try that one, and measure the voltage while the turntable is moving with a loco on it. As long as it stays at 12V or slightly higher, you'll be fine.

                                 --Randy

 


Modeling the Reading Railroad in the 1950's

 

Visit my web site at www.readingeastpenn.com for construction updates, DCC Info, and more.

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!