Posted by Mayorpete on Saturday, March 5, 2011 11:47 AM

In the process of adding onto our house, I have been blessed with a new basement room to "play trains" in. My old HO layout is 100 ft or so of DC blocks.  This new layout will be much bigger and frankIy, DC wiring would be a real headache.  I have been looking at the Digitrax and other sites to read about DCC.  This site seems to be the most honest with the best imformation.

 I just have a couple basic (stupid) questions, never having the pleasure of running a DCC system:

1.  How many locomotives can one run at one time with one throttle?  Do you get a loco going ( 2 with the Digitrax 402s), then let them run and switch to other locomotives, controlling more than 2 with the same throttle?  Or do you add enough throttles for all that you're running at once?

2.  Power Districts.  Can or should you run 2 mainline tracks (observing the 50' limit with 12 GA wire) with one bus?  Or does it need to be all split into 2 districts?  The 50' limit is clear to me, I don[t find where it says how many feet of track or how many locos can be running on that one 12 GA bus.

3.  I am thinking about a sort of 2 shelf layout.  Will I need a controller/booster on one level and then another booster on the other in a 14 x 20 room? 

Thanks, and any other words of wisdom for me would be appreciated.

  • Member since
    July 2003
  • From: Metro East St. Louis
  • 5,743 posts
Posted by simon1966 on Saturday, March 5, 2011 4:12 PM

 

No questions are stupid, if asking them leads you to better information and better choices then they served their purpose.

Mayorpete

1.  How many locomotives can one run at one time with one throttle?  Do you get a loco going ( 2 with the Digitrax 402s), then let them run and switch to other locomotives, controlling more than 2 with the same throttle?  Or do you add enough throttles for all that you're running at once?

In theory you can select a loco, start it running, select another, start it running ad infinitum and they will all keep running until you select them again and re assume control.   There are limits, usually imposed by the command station regarding how many can run at once, and of course the amount of power would be a limit.  Also there are limits imposed by yourself, namely how adept you are and if you can realistically keep up with many running at once.  So indeed you can keep selecting away and the trains will continue to run at their set speed etc until you reach an illogical conclusion Blindfold

Mayorpete

2.  Power Districts.  Can or should you run 2 mainline tracks (observing the 50' limit with 12 GA wire) with one bus?  Or does it need to be all split into 2 districts?  The 50' limit is clear to me, I don[t find where it says how many feet of track or how many locos can be running on that one 12 GA bus.

You certainly can run that as one power district if you like.  IMO if you have plenty of feeders from the bus to the track the distance/length of track is not such an issue.  The limits are more related to the number of locos running at once.   Or more specifically the current draw in any given section.  Sound locos, lit passenger trains all contribute to the draw.  The number of amps that you have will depend on your command station and any boosters you might add.   However the main advantage of several power districts is that this limits the area of the layout that would shut down due to a short.  Also if you plan on using signalling and block detection you may see the need to break things down into smaller blocks.  

Mayorpete

3.  I am thinking about a sort of 2 shelf layout.  Will I need a controller/booster on one level and then another booster on the other in a 14 x 20 room? 

You may or may not need  a second booster depending on how many locos you want to run at once.   If I were you I would choose my command station/booster and make sure it is a setup that can easily add a second booster later and see if in fact you really need one.  You may well not.   Run the power bus from the lower level up to the upper level, perhaps breaking it into a seperate power district, but powered from the same booster.   Most of the main DCC companies like Digitrax offer power management devices to allow easy setup of multiple power districts fed from one booster.

Simon Modelling CB&Q and Wabash See my slowly evolving layout on my picturetrail site http://www.picturetrail.com/simontrains and our videos at http://www.youtube.com/user/MrCrispybake?feature=mhum

  • Member since
    March 2011
  • 13 posts
Posted by Mayorpete on Saturday, March 5, 2011 5:36 PM

Thanks,  I appreciate the info.  I want to run a DCC layout before purchasing one, and don't want to buy something that I don't need.  By the same token, I want the system to run smoothly.

 I liked your comment about # of locos running at once, of course, that will depend on how well I can run the thing........

  • Member since
    May 2008
  • 4,612 posts
Posted by Hamltnblue on Sunday, March 6, 2011 8:34 AM

If you want to run a DCC layout the best thing to do is find a club in your area and give them a visit.

Many of them also have operating sessions where you can see the most out of a system.  During our monthly ops sessions we regularly have about 20 people running the same time with their own controllers and loco's

Springfield PA

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!