Trains.com

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

P2K DH165L0 and dead loco

1166 views
6 replies
1 rating 2 rating 3 rating 4 rating 5 rating
  • Member since
    September 2006
  • From: South Texas
  • 7 posts
P2K DH165L0 and dead loco
Posted by modelrrguy on Saturday, February 5, 2011 11:35 AM

Hoping someone can shed some light on this-relatively new to decoder installs.  I have a couple Proto 2000 GP-30's (old LL blue box) that I am converting to DCC (I replaced the cracked gears in both).  First one went smoothly-installed decoder, put on track and it worked.  Second one, hooked up the Digitrax DH165L0 decoder and nothing.  No lights no movement.  Put the DC board back in and put it on a DC test track and it worked fine.  Pulled the decoder out of the GP30 that worded fine and tried it, same thing, no response.  Put the decoder that wasn't working in the other looco and it worked.  Took the wiring harness and removed the black tabs, re-threaded the wires and put the black tabs back on.  Tested on DC, worked fine, put decoder back in and nothing.  Any ideas/sugestions?  Figure it's got be an electrical problem somewhere, since neither decoder worked, but not sure what to look at.  Thanks in advance for your help!!!  BTW-using MRC PA2 DCC system.

Scale-HO / Track-Brass / Power-Prodigy Advance Squared DCC (just installed 02/09) / Layout-single level, twin track, U-shaped / Benchwork-3/4" plywood and 1/2" homosote / Era-late '60's / Roadnames-UP mainly, with some SP, ATSF and BN sprinkled in AJ
  • Member since
    July 2007
  • From: Bergen County, NJ
  • 201 posts
Posted by elansp on Saturday, February 5, 2011 11:57 AM

Here you go....sounds like decoder thinks there is a short...

 

http://tsd.digitrax.com//index.php?a=170    

  • Member since
    October 2005
  • 79 posts
Posted by ianalsop on Saturday, February 5, 2011 12:09 PM

Hi,

I'm no expert but here's what I'd do.

The first thing I would try is to put the decoder into the "good" loco and reset the decoder (usually CV8 but check the manual).

Next, I would solder the wires to the circuit board - don't rely on the black tabs. Those black tabs stretch over time and although you got it to work on DC, I definitely use solder (eventually they'll come loose anyway).

Check that the decoder is fully insulated - it's possible its catching something with the bodywork on (try running it without the shell to check).

You say there's no response. I don't have the MRC system, but on my NCE you can get a read-back of the decoder manufacturer ID and version number off the programme track setting. If you can do that on the MRC and get a response, then you know there's power getting to the decoder. As you've reset the decoder, you should be able to programme CV's and hopefully get things moving.

Ian

 

  • Member since
    September 2006
  • From: South Texas
  • 7 posts
Posted by modelrrguy on Saturday, February 5, 2011 2:12 PM

Update-connected programming track section and tried to read decoder-nothing.

Scale-HO / Track-Brass / Power-Prodigy Advance Squared DCC (just installed 02/09) / Layout-single level, twin track, U-shaped / Benchwork-3/4" plywood and 1/2" homosote / Era-late '60's / Roadnames-UP mainly, with some SP, ATSF and BN sprinkled in AJ
  • Member since
    February 2002
  • From: Reading, PA
  • 30,002 posts
Posted by rrinker on Saturday, February 5, 2011 6:29 PM

 No readback can still be two things. No track power is getting to the decoder, or no decoder output is getting to the motor.

 Out of the box it should be address 03. If you select that address, can you turn the lights on and off with F0? If so, problem is between the decoder and the motor. If not, problem uis between the track pickups and the decoder. If it works wih the diode board back in for DC, then the pickups and wires are ok - however compare to the workign one to make sure the correct wires are on the correct pins for the plug board that plugs in to the decoder. If any of those are out of order it might still work fine on DC but then things would be connected to the wrong pins of the decoder so it wouldn't run.

 Sounds like you already tried a known good decoder, so it's not the decoder.

                              --Randy

 


Modeling the Reading Railroad in the 1950's

 

Visit my web site at www.readingeastpenn.com for construction updates, DCC Info, and more.

  • Member since
    September 2006
  • From: South Texas
  • 7 posts
Posted by modelrrguy on Saturday, February 5, 2011 6:56 PM

Problem solved, took it the LHS (we have one), orange and red wires mixed up on wiring harness.  I felt stupid!  I may be going color blind-I could've sworn both wires were red...learned something new though (actually, a couple things, as Mike let me watch everything he did and answered all my annoying questions with a smile).

Thanks Mike (LHS DCC Guru)!!!

Scale-HO / Track-Brass / Power-Prodigy Advance Squared DCC (just installed 02/09) / Layout-single level, twin track, U-shaped / Benchwork-3/4" plywood and 1/2" homosote / Era-late '60's / Roadnames-UP mainly, with some SP, ATSF and BN sprinkled in AJ
  • Member since
    February 2002
  • From: Reading, PA
  • 30,002 posts
Posted by rrinker on Saturday, February 5, 2011 8:21 PM

 Sometimes the most insane guess turns out to be the right one. Cool

                --Randy

 


Modeling the Reading Railroad in the 1950's

 

Visit my web site at www.readingeastpenn.com for construction updates, DCC Info, and more.

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!