Trains.com

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

power district wiring

5121 views
12 replies
1 rating 2 rating 3 rating 4 rating 5 rating
  • Member since
    February 2008
  • 3 posts
power district wiring
Posted by eldorado on Thursday, December 30, 2010 5:40 PM

can you use the same negative (  --  )  wire for your districts,  or do you need to run a negative with each power district bus. i will have three districts.

  • Member since
    January 2007
  • From: Eastern Shore Virginia
  • 3,290 posts
Posted by gandydancer19 on Thursday, December 30, 2010 6:45 PM

Power districts use a separate booster.  In that case, you need to run two new bus wires for that power district.  You must also cut a gap in both rails.

Sub power districts are made by using one or more current protection devices such as a circuit breaker or light bulb attached to the hot output wire of the booster.  In this case, you can use the same common bus wire for all sub power districts.  The new hot bus wire would come from the circuit breaker, and the hot rail must be gaped between sub districts.

Hope this helps.

Elmer.

The above is my opinion, from an active and experienced Model Railroader in N scale and HO since 1961.

(Modeling Freelance, Eastern US, HO scale, in 1962, with NCE DCC for locomotive control and a stand alone LocoNet for block detection and signals.) http://waynes-trains.com/ at home, and N scale at the Club.

  • Member since
    February 2008
  • 3 posts
Posted by eldorado on Thursday, December 30, 2010 6:49 PM

thanks thats all i needed to know .  have a happy new year

  • Member since
    January 2001
  • From: SE Minnesota
  • 6,845 posts
Posted by jrbernier on Friday, December 31, 2010 7:36 PM

  As mentioned - Power Districts are double gapped and have two wires.  A Power District can be fed by a booster, or by devices like the Digitrax PM42 - it will divide you the booster output into 4 Power Districts.    I have a Cmd Station and a Booster - The PM42 provide 2 seperate Power Districts for the Cmd Station and 2 for the Booster.  The advantage is that if I derail a train in the yard's Power District(very possible when switching), that short will not shut down the entire layout - only trains in the yard are affected.  I also have 2 main-line Power Districts and a staging Power District.  This breaks up the railroad so that the chance of a complete DCC shutdown of the layout is quite rare.

Jim

Modeling BNSF  and Milwaukee Road in SW Wisconsin

  • Member since
    March 2007
  • From: On the Banks of the Great Choptank
  • 2,916 posts
Posted by wm3798 on Wednesday, February 9, 2011 6:37 PM

Sorry for coming late to this party, but I'm getting ready to extend the wiring of my layout into the next section, and I'm thinking it would be wise to do a sub district for the yard.  I've read a couple of places about wiring an automotive brake light bulb as a circuit breaker for the sub district.

Being a very visually oriented person, I wonder if someone could produce a simple, idiot proof diagram showing how this is done.

Please bear in mind that scenery is my favorite part of the hobby, and the mysteries of what goes on in all those wires under the layout plum evade me.

Thanks in advance for your indulgence!

Lee

Route of the Alpha Jets  www.wmrywesternlines.net

  • Member since
    June 2004
  • From: From Golden, CO living in Puyallup (Seattle), WA
  • 750 posts
Posted by Renegade1c on Wednesday, February 9, 2011 7:01 PM

The blue box is my main AC Power supply. It is a 12 Amp power supply which powers both my command station/booster and booster (the gray boxes). There is a circuit breaker to prevent an overload from destroying my boosters. Connected to each booster are 4 solid state circuit breakers. The ones I bought allow you to daisy chain them on the input side to save a little bit of wiring. I have a total of 8 power districts on the layout.  Each district is electrically isolated from the others (ie double gaps at each end of the district and separate  bus wires underneath. This makes diagnosing issues much easier as well because i can locate what part of the layout the issue is coming from.

I hope this helps.

To use a light bulb, you would just place in series with one of  the bus wires for a particular district. You would need additional bulbs for each district and wire them in series for that bus wire. I however think the lightbulbs defeat the purpose of the built in circuit breakers of almost all DCC systems and refuse to use them. DC is a different matter however and they serve a good purpose there.


Colorado Front Range Railroad: 
http://www.coloradofrontrangerr.com/

flag

  • Member since
    March 2007
  • From: On the Banks of the Great Choptank
  • 2,916 posts
Posted by wm3798 on Wednesday, February 9, 2011 10:13 PM

That sound you just heard was my head exploding. ..

 

I guess it would be helpful to report that I'm using MRC Prodigy Advance.  I understand Digitrax provides a myriad of part numbers and gadgets to do all kinds of things, but it seems you have to have Mr. Science as one of your operating crew to fully understand it.

I'll try the MRC site and see if that's any use.  I'll probably just break down and buy a booster, set up a power district around that, and be done with it.

Thanks for taking a stab at it for me!

Lee

Route of the Alpha Jets  www.wmrywesternlines.net

  • Member since
    May 2009
  • 299 posts
Posted by JSperan on Wednesday, February 9, 2011 10:51 PM

Here is Joe Fugates wiring diagram for using 1156 light bulbs.

  • Member since
    July 2008
  • 1,204 posts
Posted by mfm37 on Thursday, February 10, 2011 3:20 AM

Lee,

 The light bulb goes in series with one of the bus wires going to your yard. Typically an 1156 tail light bulb. Get a socket at the local Auto parts store. There's one on RT 50. The socket will have two wires. Cut one of your bus wires and connect one of the socket's wires to each of the cut ends. Put a bulb in, turn track power on and short the track. Bulb should light but track power will stay on.

You coulda asked this on RW

Martin Myers

 

  • Member since
    February 2002
  • From: Reading, PA
  • 30,002 posts
Posted by rrinker on Thursday, February 10, 2011 8:01 AM

 What renegade has is applicable to any DCC brand, there's nothing inherently 'digitrax' about what he described otehr than he is using a Digitrax system. That could just as easily be NCE boosters or Lenz or Easy-DCC or MRC. Not sure how you could make that block diagram simpler, to describe a system with 8 power districts.EVERY system connects to the track the same way.

               --Randy

 


Modeling the Reading Railroad in the 1950's

 

Visit my web site at www.readingeastpenn.com for construction updates, DCC Info, and more.

  • Member since
    June 2004
  • From: From Golden, CO living in Puyallup (Seattle), WA
  • 750 posts
Posted by Renegade1c on Thursday, February 10, 2011 10:50 AM
Lee, Many DCC parts are compatible with other systems. The Green Boxes in my Diagram are circuit breakers (PSX-CB) made by DCC Specialties. They are probably one of the least difficult boards to use (in terms of wiring). The have six screw terminals (four on the input side, two on the output side). The wires that come from your DCC system (the gray boxes) connect to the input of the circuit breaker (green boxes). The output connects to the bus wires that go to your track. The spare set of terminals on the input side are used to daisy chain multiple circuit breakers together. I apologize if the diagram seemed a bit daunting. I just pulled it up out of my files that keep for the railroad. I have kept extensive records while building my current layout and it has helped greatly to troubleshoot issues and keep things working. I also needed the diagrams so that I can earn my MMR certificate for electrical engineering.


Colorado Front Range Railroad: 
http://www.coloradofrontrangerr.com/

flag

  • Member since
    December 2004
  • From: Bedford, MA, USA
  • 21,370 posts
Posted by MisterBeasley on Thursday, February 10, 2011 2:32 PM

Realistically, is your layout big enough to need a booster?  Will you run enough locomotives simultaneously?

My layout is a 5x12 foot table, and a 19-foot long shelf, with a balloon at one end to allow a loop there.  Part of the layout has a subway system below it.  There is a lot of track.  By myself, I usually run 2 or 3 trains at a time, with some continuously running while I switch with others.  I've got a Lenz System 100, which provides 5 amps.  That is plenty of power for this layout.

I have divided the layout into sections protected by circuit breakers.  Two sections are fairly large reverse loops, and my main yard is attached to one of the loops.  So, I've got a total of 6 sections isolated by circuit breakers.  This gives plenty of protection and separation for trouble shooting, but all of this is still driven by the single DCC system.  I run a number of illuminated passenger cars, too, and never run short of power.

I'm not sure how much power your MRC PA has, but for most home layouts boosters are overkill.

It takes an iron man to play with a toy iron horse. 

  • Member since
    March 2007
  • From: On the Banks of the Great Choptank
  • 2,916 posts
Posted by wm3798 on Saturday, February 12, 2011 1:34 PM

Thanks for the input and feedback, and all those other electronical bytes of wisdom!

I'll have to go over the layout plan and see where the best places are for districts to be cut in.

Lee

Route of the Alpha Jets  www.wmrywesternlines.net

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!