Trains.com

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Curious effect when testing motor - ?

880 views
6 replies
1 rating 2 rating 3 rating 4 rating 5 rating
  • Member since
    June 2009
  • From: QLD, Australia
  • 1,111 posts
Curious effect when testing motor - ?
Posted by tbdanny on Monday, November 15, 2010 3:58 AM

Hi all,

I've just been testing the current draw on a brand new mashima motor, and I noticed a rather curious effect.  When the throttle (straight DC) was set to somewhere in the 9-12 volt range, the current reading went off the scale - I think the highest reading was 17 amps.  But once I grabbed the shaft to stall the motor, it dropped back down to 0.25 amps.  This also happened on another motor I was testing.

I'm guessing that it's the motor's back-EMF interfering with the multimeter - would this be correct?

Cheers,

tbdanny

The Location: Forests of the Pacific Northwest, Oregon
The Year: 1948
The Scale: On30
The Blog: http://bvlcorr.tumblr.com

  • Member since
    June 2004
  • From: Orig: Tyler Texas. Lived in seven countries, now live in Sundown, Louisiana
  • 25,640 posts
Posted by jeffrey-wimberly on Monday, November 15, 2010 7:47 AM

tbdanny

I'm guessing that it's the motor's back-EMF interfering with the multimeter - would this be correct?

Sounds about right to me. It takes electricity to make the motor turn but as the the armature turns within the field of the magnets it also creates electricity and this can do strange things to power readings.

Running Bear, Sundown, Louisiana
          Joined June, 2004

Dr. Frankendiesel aka Scott Running Bear
Space Mouse for president!
15 year veteran fire fighter
Collector of Apple //e's
Running Bear Enterprises
History Channel Club life member.
beatus homo qui invenit sapientiam


  • Member since
    February 2002
  • From: Reading, PA
  • 30,002 posts
Posted by rrinker on Monday, November 15, 2010 8:09 AM

 Just as a test to verify no other problems, connect the meter in the ohms setting across the motor and slowly rotate it to connect each brush to the commutator sectiosn and check for a shorted winding - at no point should you ever get a 0 reading, if you do there is either a shorted commutator segment or a shorted winding, often caused if the motor ever overheated.

                           --Randy

 


Modeling the Reading Railroad in the 1950's

 

Visit my web site at www.readingeastpenn.com for construction updates, DCC Info, and more.

  • Member since
    May 2008
  • 4,612 posts
Posted by Hamltnblue on Monday, November 15, 2010 3:54 PM

What are you using for a power source?  make sure it isn't a pulsed power supply. 

Also how high does your meter go?  17 amps sounds a bit high for most multi-meters.  Even the good ole Simpson only goes to 10 amps.

I have a feeling that your meter auto ranged and showed 17ma or 170ma.

Springfield PA

  • Member since
    July 2006
  • 3,312 posts
Posted by locoi1sa on Monday, November 15, 2010 4:24 PM

  Take your meter off auto range. 17 amps would be blowing your 15 amp breakers in you fuse panel. Also I doubt your DC power supply is putting out 17 amps unless your using one of the transformers from a pole. Try to get a hold of an old analog meter with the needle. A DMM is sometimes too sensitive to minor changes and will bounce around  and an accurate reading is hard.

        Pete

 I pray every day I break even, Cause I can really use the money!

 I started with nothing and still have most of it left!

  • Member since
    February 2007
  • From: Christiana, TN
  • 2,134 posts
Posted by CSX Robert on Monday, November 15, 2010 7:46 PM

locoi1sa
...17 amps would be blowing your 15 amp breakers in you fuse panel..

17 amps at 12 volts wouldn't.  17 amps at 12 volts would only draw about 1.7 amps at 120 volts(it would be more, due to the inefficieny of the transformer, but nowhere near 17).

  • Member since
    February 2002
  • From: Reading, PA
  • 30,002 posts
Posted by rrinker on Monday, November 15, 2010 9:05 PM

 We've been over this one before. Simplified version: power in = power out (minus loss in the transformer/power supply). Power - volts times amps. So with an ideal power supply, no losses, 120V at 1 amp when reduced to 12V would suppyl 10 amps. Or put it another way, drawing 10 amps on the 12V side would make it draw 1 amp from your 120V wall outlet.

Note I said SIMPLFIED explanation, this is not technically 100% accurate but no way would drawing 17 amps on the 12V side draw over 15 amps on the house circuit. Not even close. if this were true it would be impossible to use a modern computer that can draw 15 amps on the 3.3V side for the CPU and another 40-50 amps on the 12V side for the video card.

                                        --Randy


Modeling the Reading Railroad in the 1950's

 

Visit my web site at www.readingeastpenn.com for construction updates, DCC Info, and more.

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!