Posted by pschuman21 on Tuesday, February 23, 2010 3:43 PM

I just bought a Lenz Set90  (v3.6) and need a transformer to power it. I already have a couple MRC power packs available, will any of them work?

1)  MRC Tech 4 Railpower 250   no (UL) tag?  <- does this matter?

1st connection is for- Variable DC

2nd connection is for- Access AC

3rd connection is for- Fixed DC (-  +)

Input: 120VAC     60HZ

Output: 18VDC, 16VAC, 21VDC ; Total Output:  17VA

 

2) MRC Tech 4 260   (UL) tag

Imput: 120VAC    60HZ

Output:  17VDC,  15VDC

Can anyone help with this? Or recomend a better idea?  Thanks.

Tags: Lenz , MRC , Tech 4 , Transformers
  • Member since
    July 2006
  • 3,312 posts
Posted by locoi1sa on Tuesday, February 23, 2010 4:02 PM

   My clubs Lenz sets use the Magna force MF615. On page 20 of the LZV100 manual there is a list of recommended power supplies. It is best not to stray from the recommended list. Keep your MRC power packs for layout lighting or the train running around the Christmas tree. Do not use them for powering your expensive DCC system. You will have problems with not enough power for the breakers to trip when a short happens.

        Pete

 I pray every day I break even, Cause I can really use the money!

 I started with nothing and still have most of it left!

  • Member since
    July 2003
  • From: Sierra Vista, Arizona
  • 13,757 posts
Posted by cacole on Tuesday, February 23, 2010 4:14 PM

The output specs on those MRC power packs indicate 17 Watts output for the Tech 4 Railpower 250 and no output rating listed for the Tech 4 260.  I don't think either one is suitable for use as a DCC power supply.  You need a transformer with at least 5 Amps output at 16-19 VAC, which equates to a power output of 95 Watts (Volts times Amps = Watts). 

Using a low powered transformer will cause the Lenz system to perform erratically if at all, and the transformer will get dangerously hot if they don't have the proper internal thermal circuit breakers..

 

  • Member since
    May 2008
  • 14 posts
Posted by pschuman21 on Tuesday, February 23, 2010 4:26 PM

Thanks too everyone that replyed, helped out alot.

  • Member since
    December 2004
  • From: Bedford, MA, USA
  • 21,483 posts
Posted by MisterBeasley on Tuesday, February 23, 2010 6:38 PM

I ran my Lenz Set 100 for quite a while on an old train transformer.  It worked fine, until I added some illuminated passenger cars and I was running sound engines.  Then I noticed that everything ran very slowly.  I'd run out of power.

I bought a 5-amp NCE power supply and I've been happy with it ever since.

It takes an iron man to play with a toy iron horse. 

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!