Basic DCC Power Buss Wiring Question.........

1208 views
4 replies
1 rating 2 rating 3 rating 4 rating 5 rating
  • Member since
    September 2003
  • From: Southeast Texas
  • 5,449 posts
Basic DCC Power Buss Wiring Question.........
Posted by mobilman44 on Thursday, October 29, 2009 12:43 PM

Hi!

I'm putting in the main level power buss wiring on my two level DCC HO Layout and have a hopefully "easy" question.......

For much of the layout, I have three tracks running fairly parallel around the layout.  Two are main lines, one a "sub-main" that connects into the terminals, yard, sidings and the like.  Each of these three tracks will hook to a separate circuit.  To keep the buss wires (#14awg) in place, I am using the circular plastic wire holders that screw into the benchwork.

My question is, is there any problem with running the wires from the different power districts through the same wire holder?  I figure it shouldn't make a difference, but sure want the experts opinions as it is a bear wrapping my ol bod in and around the benchwork legs.

 Thank you,

Mobilman44  

ENJOY  !

 

Mobilman44

 

Living in southeast Texas, formerly modeling the "postwar" Santa Fe and Illinois Central 

  • Member since
    September 2009
  • 11 posts
Posted by ktop on Thursday, October 29, 2009 2:03 PM

I have a double main line with sub lines.  I try to keep the wires seperated as much as possible.  There are a few spots where they run together and I've never had an interference issue with them.

  • Member since
    February 2005
  • From: Vancouver Island, BC
  • 23,330 posts
Posted by selector on Thursday, October 29, 2009 2:27 PM

Have you thought of braiding them?

Shy

No...okay, I would think winding them would be useful for really long runs, but remember that the rails, themselves, are uninsulated and run parallel to each other only 16 mm apart for extended distances.  They, too, carry the signal and host voltage.

  • Member since
    July 2006
  • From: Vail, AZ
  • 1,943 posts
Posted by Vail and Southwestern RR on Thursday, October 29, 2009 4:17 PM

It won't be a problem.

The signal is huge, and not high frequency.  And the signals are all in phase, not fighting eacy other.  Lots of reasons why it should not be a problem at all.

Jeff But it's a dry heat!

  • Member since
    February 2006
  • From: Gahanna, Ohio
  • 1,987 posts
Posted by jbinkley60 on Thursday, October 29, 2009 6:53 PM

Vail and Southwestern RR

It won't be a problem.

The signal is huge, and not high frequency.  And the signals are all in phase, not fighting eacy other.  Lots of reasons why it should not be a problem at all.

And the source impedance is very low, which makes it very difficult to induce a signal of any strength.  And since the signals are in phase etc etc etc.... 

 

Engineer Jeff NS Nut
Visit my layout at: http://www.thebinks.com/trains/

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!