Trains.com

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Help with proposed crossover in my track plan...

4569 views
42 replies
1 rating 2 rating 3 rating 4 rating 5 rating
  • Member since
    February 2007
  • From: Christiana, TN
  • 2,134 posts
Posted by CSX Robert on Wednesday, October 14, 2009 8:11 PM
gtw1969
or maybe just keep it simple and hook up some kind of SPDT switch if that is possible.
It would have to be a DPDT switch, but it is certainly doable. The polarity of the reversing loop will depend on which way the turnouts in the crossover are set(if they are set to go straight, the loops will match, set to go through the crossover and one loop has to be reversed), so you might could even incorporate it into your turnout control. For example, if you are using a DPDT switch to control the turnout, you could replace it with a 4PDT switch, or if your turnouts are thrown using solenoid switch machines, you could have a DPDT latching relay wired to activate at the same time as the crossover switches.
  • Member since
    September 2004
  • From: Dearborn Station
  • 24,281 posts
Posted by richhotrain on Thursday, October 15, 2009 6:07 AM

gtw1969

CSX Robert,
I think that might be the case as well. After going over every square inch of my wiring, I can't seem to find any faults. And you mentioning my Dynamis shorting out quickly.....that is happening. I have read about those other auto-reverse devices (solid state), and decided to go with the MRC because of cost (middle of the road really). I wish I had an MRC based command console to see if it works with it, but I don't. Looks like I might have to splurge and get the solid state version or maybe just keep it simple and hook up some kind of SPDT switch if that is possible.

gtw1969,

Keep us posted as to how this problem gets resolved.  It will be interesting if a solid state reverser solves the porblem, since it seems that your wiring is in good order. 

Good luck !

Rich

Alton Junction

  • Member since
    February 2002
  • From: Reading, PA
  • 30,002 posts
Posted by rrinker on Thursday, October 15, 2009 6:28 AM

 The issue here is in the trip time/trip current. You don;t necessarily need a solid state reverser - the MRC one has absolutely no adjustments, whereas something like the Digitrax AR1 has a knob to adjust the trip current.

                                    --Randy

 


Modeling the Reading Railroad in the 1950's

 

Visit my web site at www.readingeastpenn.com for construction updates, DCC Info, and more.

  • Member since
    December 2007
  • From: Gateway City
  • 1,593 posts
Posted by yankee flyer on Thursday, October 15, 2009 9:14 AM

rrinker
 The issue here is in the trip time/trip current. You don;t necessarily need a solid state reverser - the MRC one has absolutely no adjustments, whereas something like the Digitrax AR1 has a knob to adjust the trip current.

I used the AR1 for a reversing loop on my power cab layout and fought it for a long time, Finely gave it away. I use a DPDT,  and throw it at the same time I through the diverting turnout. My theory is the circuit that protects the Power Cab trips before the AR1. I believe you will have trouble adjusting the AR1 to work with any low power command system.
My My 2 cents others may disagree. Oh by the way in OP I thought your reference to a cross over meant a diamond type cross over, not a double turnout. Sorry.

 Good luck

Lee 

  • Member since
    September 2004
  • From: Dearborn Station
  • 24,281 posts
Posted by richhotrain on Thursday, October 15, 2009 10:46 AM

yankee flyer

rrinker
 The issue here is in the trip time/trip current. You don;t necessarily need a solid state reverser - the MRC one has absolutely no adjustments, whereas something like the Digitrax AR1 has a knob to adjust the trip current.

I used the AR1 for a reversing loop on my power cab layout and fought it for a long time, Finely gave it away. I use a DPDT,  and throw it at the same time I through the diverting turnout. My theory is the circuit that protects the Power Cab trips before the AR1. I believe you will have trouble adjusting the AR1 to work with any low power command system.
My My 2 cents others may disagree. Oh by the way in OP I thought your reference to a cross over meant a diamond type cross over, not a double turnout. Sorry.

 Good luck

Lee 

I have two Digitrax AR-1 reverser units on my layout and never have had a porblem.  I have an NCE PH-Pro 5 amp DCC system.  Doesn't the AR-1 work equally well on all DCC systems?  Maybe not.

Rich

Alton Junction

  • Member since
    December 2007
  • From: Gateway City
  • 1,593 posts
Posted by yankee flyer on Thursday, October 15, 2009 11:06 AM

richhotrain
I have two Digitrax AR-1 reverser units on my layout and never have had a porblem.  I have an NCE PH-Pro 5 amp DCC system.  Doesn't the AR-1 work equally well on all DCC systems?  Maybe not.

That's my point, 5 amps is'nt low power. The  Zephyr, Power Cab or something like that may not play well with AR1. I bought the Zephyr and AR1 together and could not get either one to work for any length of time. (no flame please) I then bought Power Cab and plugged it into same layout. No problems except for AR1.
That's just my experience on my lay out. Confused

Good luck

Lee

  • Member since
    February 2009
  • From: Warren, MI
  • 55 posts
Posted by gtw1969 on Thursday, October 15, 2009 1:36 PM

Well guys, I decided to go with the DPDT switch. I gave it a try to see how it would be, and it's quite easy. Yeah it's not automatic, but only requires the operator to throw one switch while in the loop. Plus, it's difficult spending another chunk of change on a solid-state unit, not knowing if its really going to work or not for me.

So on to another "idea" I'm trying to come up with. Is there a way to control the whole setup with one DPDT. In other words, I have (2) tortoise machines that will control my crossover turnouts, plus the DPDT for the polarity change. Can I some how wire all of that together so that when I set the crossover for the train to enter the loop track it also matches the polarity of the main track. Then once the final car or caboose for my freight purposes, passes through the crossover, I flick the switch, and polarity is changed, and crossovers close at the same time. Make sense? Can it be done? Should I add indicator lights somehow in all of this? If so, what do I need. Sorry for all of the questions, but I am by far no electronics expert! lol

Thanks guys!!!

 

Steve Rigelhof http://sr-graphics.net
  • Member since
    December 2007
  • From: Gateway City
  • 1,593 posts
Posted by yankee flyer on Thursday, October 15, 2009 3:16 PM

gtw1969

So on to another "idea" I'm trying to come up with. Is there a way to control the whole setup with one DPDT. In other words, I have (2) tortoise machines that will control my crossover turnouts, plus the DPDT for the polarity change. Can I some how wire all of that together so that when I set the crossover for the train to enter the loop track it also matches the polarity of the main track. Then once the final car or caboose for my freight purposes, passes through the crossover, I flick the switch, and polarity is changed, and crossovers close at the same time. Make sense? Can it be done? Should I add indicator lights somehow in all of this? If so, what do I need. Sorry for all of the questions, but I am by far no electronics expert! lol

Thanks guys!!!

 

Like I said I do the same thing with Atlas turn outs and their slide switches and motors. One slide switch throws the  turn out motor  It is positioned on my control panel so that when the train is ready to enter the turn around loop "Y" I throw the turn out slide switch to the direction I want to go and at the same time throw the DPDT track power switch in the same direction. of course you have to rotate the tract power switch so that it delivers power in the direction you want. On my crossover track one slide switch throws both turn out motors, because my track is a folded loop I don't have the polarity problem.
Someone may make a 4P4T switch that would help your problem?

On the other hand isn't the tortoise switch motor power routing?
Someone else will have to expand on that subject.

Good luck

Lee  Big Smile

  • Member since
    September 2004
  • From: Dearborn Station
  • 24,281 posts
Posted by richhotrain on Thursday, October 15, 2009 5:43 PM

gtw1969

Well guys, I decided to go with the DPDT switch. I gave it a try to see how it would be, and it's quite easy. Yeah it's not automatic, but only requires the operator to throw one switch while in the loop. Plus, it's difficult spending another chunk of change on a solid-state unit, not knowing if its really going to work or not for me.

 

I will say this.  If the DPDT switch works, a solid state reverser will work.

Whenever I need a reverser, I first attempt the operation with a DPDT to "test" the arrangement.

If the DPDT switch works, the auto reverser will work.

Alton Junction

  • Member since
    February 2007
  • From: Christiana, TN
  • 2,134 posts
Posted by CSX Robert on Thursday, October 15, 2009 9:01 PM
gtw1969
Is there a way to control the whole setup with one DPDT. In other words, I have (2) tortoise machines that will control my crossover turnouts, plus the DPDT for the polarity change. Can I some how wire all of that together so that when I set the crossover for the train to enter the loop track it also matches the polarity of the main track. Then once the final car or caboose for my freight purposes, passes through the crossover, I flick the switch, and polarity is changed, and crossovers close at the same time. Make sense? Can it be done?
It can be done quite easily if you replace the DPDT switch with a 4PDT switch(use two of the poles for the track polarity and the other two for the tortoises). You could do it with the DPDT by using terminals on the tortoise to switch that track polarity, but the problem with doing it that way is the track would momentarily be dead in the middle of the turnout's throw.
  • Member since
    February 2002
  • From: Reading, PA
  • 30,002 posts
Posted by rrinker on Friday, October 16, 2009 6:36 AM

 The Zephyr will work fine with an AR1 - because you can adjust the trip speed. Leaving it at the default will probably mean no workie with the AR1 or any other auto reverser. Changing to the next slower setting from default will give time for the AR1 or other autoreverser to function before the Zephyr itself cuts power.

 The PowerCab does not have any such adjustment. Neither does the SB3 which is why the pulled them off the market for a redesign. Neither one works very well with autoreversers and circuit breakers other than the NCE one which is just lightbulbs.

 Really low power systems like EZ DCC will probably have problems no matter what, they just don't put out enough power AND they lack a trip speed adjustment.

                           --Randy

 


Modeling the Reading Railroad in the 1950's

 

Visit my web site at www.readingeastpenn.com for construction updates, DCC Info, and more.

  • Member since
    February 2009
  • From: Warren, MI
  • 55 posts
Posted by gtw1969 on Sunday, October 18, 2009 8:12 PM

Hey guys,
I just wanted to follow up on my original post. This might help out someone else with a similar situation to mine, regarding reverse loops. I ended up going the simple route, typically used by "old school" DC operators, using a DPDT switch to control polarity with three insulator blocks setup near/on the crossover. My trains run flawlessly through the crossover this way. Then once the last car passes the crossover, I hit the polarity switch, and the train is good to complete the reverse loop. With me using the Bachmann Dynamis system and not having the funds to try out different auto-reverse modules to see if they work with my system, this approach made the most sense to me.

I have to say this is my first attempt at installing/using Tortoise switches and building a control panel for my layout. I'm VERY inpressed with the Tortoise switches and look forward installing the other twenty or so I have to do! Also looking forward to the wiring mess!...haha

Check out the pic I took of my new control panel for the cross-over area:

Thanks for all of your help!!!

 

Steve Rigelhof http://sr-graphics.net

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!