NCE swith 8 issue
Posted by Hamltnblue on Sunday, July 26, 2009 9:02 PM

  #1   Report Post  
Old Today, 10:01 PM
hamltnblue hamltnblue is online now vbmenu_register("postmenu_135992", true);
Engineer
 
Join Date: Apr 2008
Location: Springfield PA
Posts: 519
Default NCE Switch 8

Hello All
I just installed an NCE switch 8 hooking up 5 outputs. 3 of the outputs are powering 2 tortoise switch engines. The other 2 are powering 1. The input voltage is 14v off the track. My problem is after power up the unit will not switch the torti's. They go to default position but won't respond to a control. If I cycle power on the switch 8 only the unit will respond. Should I adjust the track voltage a little higher or do I have a bad unit? My base unit is a 5 amp phpro.
Thanks

Springfield PA

  • Member since
    July 2003
  • From: Sierra Vista, Arizona
  • 13,757 posts
Posted by cacole on Sunday, July 26, 2009 9:22 PM

 Did you assign an address to each Tortoise, and are you using your Power House Pro's controller to tell the Switch 8 to throw the switch using those addresses?  I use the NCE SwitchIt controllers and had to assign an address to each output.

I'm not familiar with the Switch8, but with the SwitchIt you have to put a jumper wire between two screw terminals, operate the turnout on the desired address, and then remove the jumper.

Go through your Switch8 instructions and make sure you are assigning a different address to each Tortoise.

  • Member since
    May 2008
  • 4,612 posts
Posted by Hamltnblue on Monday, July 27, 2009 3:11 PM

The switches respond. The problem is that more times than not I have to cycle power to the unit several times to get it to respond.  The first address had been working and stopped.  It has voltage output but seems to have lost it's program.

Springfield PA

  • Member since
    July 2003
  • From: Sierra Vista, Arizona
  • 13,757 posts
Posted by cacole on Monday, July 27, 2009 7:57 PM

 It sounds like two possible causes:  A poor electrical connection between your track or booster and the Switch8, or your power supply is not putting enough amperage to the Switch8 (or the voltage is low).

If you have a voltmeter, set it on the AC Volts range and read the voltage going into the Switch8.  You should have something in the range of 14.5 Volts AC, plus or minus .1 Volt.  If you don't get this reading, something is amiss with your power supply.

  • Member since
    May 2008
  • 4,612 posts
Posted by Hamltnblue on Monday, July 27, 2009 8:02 PM

Voltage under load is 14.2 at the unit. It's powered by a PH Pro 5 amp DCC System.  I noted the voltage to the NCE tech and he didn't think adjusting track voltage would help.

Springfield PA

  • Member since
    July 2003
  • From: Sierra Vista, Arizona
  • 13,757 posts
Posted by cacole on Monday, July 27, 2009 10:20 PM

 What gauge wire did you use to connect the Switch8 to the track.  I used 18 gauge stranded speaker wire connected to the track bus wiring and have never had problems with the SwitchIt controllers.

You may have a defective Switch8, but it sounds to me like it is not receiving adequate amperage.

  • Member since
    May 2008
  • 4,612 posts
Posted by Hamltnblue on Tuesday, July 28, 2009 2:34 PM

It's 18 or 16 gauge connected directly to the 14 gauge bus.  I measured the voltage under load at the input terminals. 

Springfield PA

  • Member since
    February 2008
  • 8,877 posts
Posted by maxman on Tuesday, July 28, 2009 3:19 PM

I think your wire size is okay, especially if the run is short.

Are you certain that you are following the programming instructions properly?  And did you remove that programming jumper when you were done programming?

  • Member since
    May 2008
  • 4,612 posts
Posted by Hamltnblue on Tuesday, July 28, 2009 4:31 PM

Yes.  Remember the unit runs fine.  If you cycle power for any reason the unit stops responding to commands.  After cycling power several times it will start working again. It is at default address. Heat shouldn't be an issue since the basement is about 72 degrees F.

Since my last post I installed a new unit.  I will be needing one for 4 upcoming torti's on another section of the layout.  I figured I'd get it up front and try it out.  It works fine.  The other unit will be returned for repair/replacement.

Thanks for the input all.

Springfield PA

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!