Posted by willy6 on Tuesday, July 14, 2009 11:48 PM

My last layout was 4ft x 13ft, HO and wired for DC. I had 3-4ft blocks that were isolated with insulated rail joiners on both the negative and positive rail. It ran fine. I finally was convinced to go DCC. I got the Digitrax empire builder. Just to see how it worked, I wired all the negatives to the unit and did the same with the positives. It worked fine. I was impressed with DCC. Now I'm building a new layout and getting ready to lay the track (HO code 83). Now with DCC, will I need blocks or can I just run feeder wires right to the bus wires?

Being old is when you didn't loose it, it's that you just can't remember where you put it.
  • Member since
    February 2005
  • From: Southwest US
  • 12,914 posts
Posted by tomikawaTT on Wednesday, July 15, 2009 1:30 AM

With DCC, you still need gaps between hot-frog turnouts at the opposite ends of a double-ended siding.

It might also be desirable to have some isolated tracks for hidden staging or locomotive parking.  The easy way is to gap one rail and power it through an SPST switch.

Some day, you might want to install signals operated by detector circuits.  It's a lot easier to gap the rails during tracklaying than it is to cut gaps in finished trackwork.

The bottom line - figure out where you might need gaps and provide for them from the start.  It will probably have considerable resemblance to a DC layout gapped for cab control.  Connect feeders to the busses where they can be reached without standing on your head under the layout.  When you start installing signal detectors, you'll be glad you did.

Chuck (Modeling Central Japan in September, 1964)

  • Member since
    February 2002
  • From: Westchester NY
  • 1,747 posts
Posted by retsignalmtr on Wednesday, July 15, 2009 6:56 AM

Unless you are using electrofrog switches, are going to have a reverse loop or a wye, you will not need them. Any insulated sections you may need can easily be made with a razor saw or dermmel to cut the gaps then using CA cement in a piece of styrene. An engine terminal should have some isolated tracks with toggle switches to shut off non-dcc locos and others to keep the power draw low. Run the feeders right to the buss.

My clubs original DC layout was built with soo many I.J.s we had to solder in three times the # of track feeders when we converted to DCC than if we had started building a new layout.

  • Member since
    June 2009
  • From: QLD, Australia
  • 1,111 posts
Posted by tbdanny on Thursday, July 16, 2009 1:16 AM

Depending on the size of your layout, you may like to break the track up into individual 'power districts'.  These are wired the same way as blocks in DC, with the exception that each power district runs through some sort of circuit breaker before joining the main DCC unit.  This prevents a short circuit from shutting down/damaging all of the layout, and also makes it easier to troubleshoot electrical faults.

Several manufacturers sell these circuit breakers.  Some are adjustable, some are as simple as tail lights in series with the track bus.  Whatever one looks best for you is probably the one to go with.

The Location: Forests of the Pacific Northwest, Oregon
The Year: 1948
The Scale: On30
The Blog: http://bvlcorr.tumblr.com

  • Member since
    December 2004
  • 106 posts
Posted by spearo on Friday, July 17, 2009 8:31 AM

Check out this site;

http://www.wiringfordcc.com/track.htm

Has more info on DCC  than I think you could ever want.

  • Member since
    June 2005
  • From: Phoenixville, PA
  • 3,495 posts
Posted by nbrodar on Friday, July 17, 2009 10:31 AM

 Using DCC friendly turnouts, the only places you need gaps are reversing sections and boundaries for power districts and sub districts.

However, if you want to add signalling, using current sensing detectors, you'll have to gap the track for the signal blocks.   Also if you want to be able to cut power specific areas, you'll need gaps.   

For example, I don't like leaving my decorders sitting hot, while not being used, so all of my yard and engine facility tracks are gapped and switched.  I also plan on adding signalling, so the mains are gapped for that purpose.   When all's said and done, the gap placement looks a lot like that of a conventional DC layout.

Nick

Take a Ride on the Reading with the: Reading Company Technical & Historical Society http://www.readingrailroad.org/

  • Member since
    July 2006
  • From: 4610 Metre's North of the Fortyninth on the left coast of Canada
  • 9,352 posts
Posted by BATMAN on Friday, July 17, 2009 2:48 PM

nbrodar

For example, I don't like leaving my decorders sitting hot, while not being used, so all of my yard and engine facility tracks are gapped and switched.

Nick

 

Just curious Nick. Does leaving them hot wear them out sooner or is there some other reason you do this? It seems like it would be a prudent thing to do and I am just starting my loco parking lot. Thanks.

 

                                                                 Brent

Brent

"All of the world's problems are the result of the difference between how we think and how the world works."

  • Member since
    June 2005
  • From: Phoenixville, PA
  • 3,495 posts
Posted by nbrodar on Friday, July 17, 2009 10:11 PM

Even when sitting idle, the decoders still draw some current plus my cabooses and passenger cars have lighting and markers powered off the track.  It's also a precaution against someone accidentally leaving the unit attached to a cab and moving it by mistake.   And don't forget the cacophony of noise when operators forget to turn the sounds off.

Additionally, I still have some units without decoders, so I can turn off the track and still have them in the engine terminal.

Nick

Take a Ride on the Reading with the: Reading Company Technical & Historical Society http://www.readingrailroad.org/

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!