Posted by dm9538 on Saturday, May 30, 2009 9:42 PM

I am thinking about beginnig to wire my layout and am seeking some input on wire colors. My layout will have four power districts, I know I need to run a seperate bus for each district. my question is do I run the busses with one common color i.e. black and change the color on the other wire for each district thus needing 5 wire colors. Or is it easier to run each district with it's own two colors thus needing 8 different colors of wire. I am interested in your thoughts.

Dan Metzger

  • Member since
    June 2005
  • From: Phoenixville, PA
  • 3,495 posts
Posted by nbrodar on Saturday, May 30, 2009 11:02 PM

 I use colors to identify the wire's purpose not it's run.  All my buss pairs are red/black.  However, I label each buss pair with it's power district.  I find it a lot easier to have just a few colors designating DCC buss, accessory ground, accessory control and signal lines, and to clearly label each run.

Nick

Take a Ride on the Reading with the: Reading Company Technical & Historical Society http://www.readingrailroad.org/

  • Member since
    February 2005
  • From: Vancouver Island, BC
  • 23,321 posts
Posted by selector on Sunday, May 31, 2009 12:19 AM

I agree, stick to left and right, red or black, and use tape to label the runs/pairs every change of orientation or direction, or after every passage through a bulkead or frame member.

-Crandell

  • Member since
    May 2002
  • From: Massachusetts
  • 2,890 posts
Posted by Paul3 on Sunday, May 31, 2009 11:42 AM

Dan,
When you say "power districts", are you talking one booster powering 4 circuit breakers, or 4 boosters?  I would be more inclined to use different colors for 4 boosters than just for one.

Still, I think the question here is, are you going to have a situation where these multiple "power districts" overlap?  If they are simply bordering each other at the ends, then there is no reason to use multiple colors.  However, if you have a spaghetti bowl layout with multiple loops and each with it's own power district, then more colors may not be such a bad idea.

At our club, our wiring can be classed by size/type, color, and placement under the layout.  We use nylon loops for all wiring, and we stack these in various locales to run the wire.

Colors:
a). red/black = track power bus
b). blue/brown/white/yellow = accessory DC bus
c). gray cable = switch machine control wire
d). silver cable = LocoNet
e). yellow = frog power wire
f). blue = diamond power wire
g). green = ground wire
h). brown/blue = stationary decoder bus
i). orange/purple = programming track wire

Size/type:
A). 10AWG = main bus from boosters to breaker panels
B). 14 AWG = track or detection bus, accessory power
C). 20 AWG = feeders and bond wires
D). round cable, 6 to 12 cond. = switch machine cable
E). flat cable, 6 cond. = LocoNet
F). ribbon cable, 10 cond. = signaling wire

Placement:
1). directly under the track = track bus
2). on the inside beam of layout = detection bus, main bus, accessory bus, etc.
3). on the outside beam of layout = LocoNet, switch machine wires
4). under middle of layout = signaling wire, switch machines, accesories, frog wires, etc.

Therefore, if I see 14AWG red/black wire running under the middle of the track above it, I know it's track power for that block.  If I see 14AWG red/black wire running along the side of the layout, I know it's the detection bus.  If I see 14AWG brown/blue wire, I know that's the wire that powers the stationary decoders.  And so on.

Paul A. Cutler III
*******************
Weather Or No Go New Haven
*******************

  • Member since
    December 2002
  • From: Overland Park, KS
  • 343 posts
Posted by dadret on Sunday, May 31, 2009 1:31 PM

I'd stick with two colors - 8 could get very confusing and I'm not sure you can find wire in 8 different colors anyway.  I used red/black

  • Member since
    February 2002
  • From: Reading, PA
  • 30,002 posts
Posted by rrinker on Sunday, May 31, 2009 2:24 PM

 Tip: in dim light, red and black look the same. Try Red and White.

                                    --Randy

 


Modeling the Reading Railroad in the 1950's

 

Visit my web site at www.readingeastpenn.com for construction updates, DCC Info, and more.

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!