Trains.com

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Revering Loop Goes Dead

1759 views
9 replies
1 rating 2 rating 3 rating 4 rating 5 rating
  • Member since
    October 2004
  • 202 posts
Revering Loop Goes Dead
Posted by rlandry6 on Tuesday, August 26, 2008 7:59 AM

The "X"s indicate where I isolated track from the mainline. When the loco enters the islolated section from either direction, the AR1 relay clicks but that section goes dead. If I leave track power on and manually push the loco out of the section, I can hear the AR1 relay click when the loco leaves the isolated section and that loco will resume running . I tried the AR1 on the other reversing loop and it works fine. I can run another loco on a different portion of the layout and when the reversing loop in question shuts off, the other loco continues to run so the entire layou is not being shutdown. I havn't broken the layout into power districts yet, so as of now, the Zephyr is powering the layout as one large power district. Any ideas, anyone?

  • Member since
    December 2004
  • From: Bedford, MA, USA
  • 21,483 posts
Posted by MisterBeasley on Tuesday, August 26, 2008 8:07 AM

Re-check your wiring and the isolation of the crossover track.  Make sure both rails are isolated on both ends.

Are you by any chance running a DC loco (as Engine Zero) for this test?  DC locos don't get along well with auto-reversers.

It takes an iron man to play with a toy iron horse. 

  • Member since
    October 2004
  • 202 posts
Posted by rlandry6 on Tuesday, August 26, 2008 8:26 AM

The track is in fact isolated on both ends and I and using a DCC loco, several different ones.. Could my track be isolate at the wrong locations? The AR1 is wired just like the other one that's working fine..

 

  • Member since
    July 2003
  • From: Sierra Vista, Arizona
  • 13,757 posts
Posted by cacole on Tuesday, August 26, 2008 8:41 AM

If the other AR1 is working okay, swap them out and see what happens.  If the good AR1 functions properly in the other location, then you have a faulty AR1 if you're absolutely sure you have both wired properly.  Double and triple check to make sure the "bad" AR1 is properly connected, and check the input side terminals with a VOM to make sure the input side is wired right.

Problems like this are why I always use terminal blocks and crimp-on terminals for all of my wiring.  If you have soldered the AR1 in place, it's very difficult to change it.

  • Member since
    July 2006
  • From: Vail, AZ
  • 1,943 posts
Posted by Vail and Southwestern RR on Tuesday, August 26, 2008 10:14 AM
The autoreverser should only trip at one end of the section or the other.  I'm thinking both rails in the reverse section are hooked to the same output or the reverser, or one of them isn't hooked to the reverser at all.  A volmeter, and tripping the reverser by just shorting the rails would tell a lot.

Jeff But it's a dry heat!

  • Member since
    June 2004
  • From: Orig: Tyler Texas. Lived in seven countries, now live in Sundown, Louisiana
  • 25,640 posts
Posted by jeffrey-wimberly on Tuesday, August 26, 2008 10:21 AM

 Vail and Southwestern RR wrote:
The autoreverser should only trip at one end of the section or the other.  I'm thinking both rails in the reverse section are hooked to the same output or the reverser, or one of them isn't hooked to the reverser at all.  A volmeter, and tripping the reverser by just shorting the rails would tell a lot.

Jeff: you beat me to it. Also, if the reversing unit checks out as good you may have bad connection from the source of the power for the crossover.

Running Bear, Sundown, Louisiana
          Joined June, 2004

Dr. Frankendiesel aka Scott Running Bear
Space Mouse for president!
15 year veteran fire fighter
Collector of Apple //e's
Running Bear Enterprises
History Channel Club life member.
beatus homo qui invenit sapientiam


  • Member since
    December 2004
  • From: Bedford, MA, USA
  • 21,483 posts
Posted by MisterBeasley on Tuesday, August 26, 2008 10:27 AM

If you shut down the system and put the loco entirely on the reversing section, and then power up, does the loco run?

Is this a simplified diagram, or are there other tracks connected to the crossover section?  If so, do any of those tracks have feeders you might have overlooked?  You need to be sure that all feeders to the crossover section are connected through the AR1.

It takes an iron man to play with a toy iron horse. 

  • Member since
    January 2008
  • From: Central Georgia
  • 921 posts
Posted by Johnnny_reb on Tuesday, August 26, 2008 11:05 AM

Just to make sure I understand it correctly. Both rails at both ends should be gapped, if I use an "AR" unit I have to completely isolate the reversing section. So I should have four isolation gaps in the reversing section? Two at one end and two more at the other end?

 

_____x__________________________left rail__________________________x______

_____x__________________________right rail_________________________x______

Johnnny_reb Once a word is spoken it can not be unspoken!

My Train Page   My Photobucket Page   My YouTube Channel

  • Member since
    December 2004
  • From: Bedford, MA, USA
  • 21,483 posts
Posted by MisterBeasley on Tuesday, August 26, 2008 11:48 AM
 Johnnny_reb wrote:

Just to make sure I understand it correctly. Both rails at both ends should be gapped, if I use an "AR" unit I have to completely isolate the reversing section. So I should have four isolation gaps in the reversing section? Two at one end and two more at the other end?

Yes, that's the right interpretation.

It takes an iron man to play with a toy iron horse. 

  • Member since
    February 2005
  • From: Vancouver Island, BC
  • 23,330 posts
Posted by selector on Tuesday, August 26, 2008 11:55 AM
Your diagram suggests you have it all figured out.  If the rails are truly gapped on each end of the reversing section, and the feeders are mechanically sound as they contact the rails, then you have a faulty connection at the AR, probably at the output since it seems to get the go-ahead to reverse polarity...you can hear it click, the LED blinks....it's wired okay input-wise.  So, maybe an internal defect at the outputs?  Or, the wire is simply not contacting the metal in one of the terminals properly?

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!