Posted by graymatter on Tuesday, January 30, 2018 11:18 AM

No automatic alt text available.Does anyone know why the Germans would put a set of fans on a WWII era steam locomotive tender?

  • Member since
    May 2010
  • From: SE. WI.
  • 8,253 posts
Posted by mbinsewi on Tuesday, January 30, 2018 11:24 AM

I would guess it has something to do with cooling fans for condensation.  Maybe a certain amount of water went back through the tender to be cooled, kind of like the cooling towers on a power plant?

I dunno, just a quess.  They seem like really BIG fans.

Mike.

  • Member since
    January 2017
  • 2,980 posts
Posted by NWP SWP on Tuesday, January 30, 2018 12:32 PM

It is a Condenser the used steam would go through a group of large "radiators" in which the steam would become water again and be reused...

Steve

If everything seems under control, you're not going fast enough!

  • Member since
    February 2008
  • From: Potomac Yard
  • 2,761 posts
Posted by NittanyLion on Tuesday, January 30, 2018 10:03 PM

Deutsche Riechsbahn only built a few hundred of them equipped that way for service on the Eastern Front.  They wouldn't emit any steam exhaust plumes with those condensers, so it was trickier for those IL-2 Sturmoviks to find them.

  • Member since
    April 2017
  • 127 posts
Posted by graymatter on Tuesday, January 30, 2018 10:10 PM

That is what I thought, they where avoiding marauding fighter planes. But how do you get the smoke out of the stack with out steam? Maybe compressed air?

  • Member since
    January 2017
  • 2,980 posts
Posted by NWP SWP on Wednesday, January 31, 2018 12:37 AM

Perhaps they used a fan or blower of some sort... they obviously had powerful enough fans to run the condenser...

Steve

If everything seems under control, you're not going fast enough!

NDG
  • Member since
    December 2013
  • 1,605 posts
Posted by NDG on Wednesday, January 31, 2018 8:37 AM

Thank You.

  • Member since
    September 2003
  • 21,326 posts
Posted by Overmod on Wednesday, January 31, 2018 10:14 AM

If interested in this technical subject, look up the 'improved' African fan arrangement, which reduced wear from 'char', ash, and heat on the fan blades.

If you are using boiler-water treatment or operating in known bad-water areas, condensing may make sense for economic rather than life-extending reasons.  It may also help with reducing back pressure in the cylinders.  Note the arguments made for the idea in the ACE3000 patent description.

At least one of the British steam-turbine-electrics used a 'wet' condenser, where dirty or even gray water can be sprayed over the coils, greatly improving efficiency well into liquid phase for the 'good' water in the Rankine cycle.  This renains really the only sort of approach that works without compromise on large North American power within sane packaging requirements...

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!