Trains.com

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

new here... and need block control help

737 views
6 replies
1 rating 2 rating 3 rating 4 rating 5 rating
  • Member since
    April 2003
  • 305,205 posts
new here... and need block control help
Posted by Anonymous on Sunday, April 24, 2005 12:06 AM
My son and I are discovering this hobby together and have started out first n-scale layout.

We are working with Kato unitrack and have started with a 36"x80" hollow-core door for our base. We've gone down the path of "pink foam", Woodland Scenics risers and plaster cloth. So far, so good.

Where I'm scratching my head is how to wire the layout we've designed (we are doing block control, not DCC). We're looking for tips on how to wire for block control for two trains where we have alot of power routing switches.

I thought I could include a drawing of our layout in this posting, but didn't see an obvious way to do that.

Anyway, we've been lurkers for a while and decided to jump into the fray. Hopefully over time we can offer advice instead of just looking for it. BLOCKED SCRIPTinsertsmilie('[;)]')
  • Member since
    April 2003
  • 305,205 posts
Posted by Anonymous on Sunday, April 24, 2005 12:28 AM
Atlas has a great book on wiring layouts and of course promoting their line of switches. The essentials are one rail is common and can be continuous and only requires it to be wired at one spot. The other rail needs to be cut at both end of the block. The cut can create derailing problems if not filled with something. The gap can be filled with a piece of strip plastic glued in the gap and filed to shape or insulated track connectors. The insulated track connectors can cause a gap on the other side. I use two insulated joiners at the end of each block to eliminate the gaposess problems and wire both rails in each block. Electrical switches between the power source and the track determine which power source and which direction. There are single power packs with dual control but it's generally regarded as best practice to have two separate power sources.
  • Member since
    September 2003
  • From: Omaha, NE
  • 10,621 posts
Posted by dehusman on Sunday, April 24, 2005 1:58 AM
I you consider only the main track switches, those on sidings or junctions, not industries, a quick rule of thumb is any track with a frog on each end needs insulating joints.

Dave H.

Dave H. Painted side goes up. My website : wnbranch.com

  • Member since
    April 2003
  • 305,205 posts
Posted by Anonymous on Sunday, April 24, 2005 2:04 AM
Dave,
Since I isolate everything I got something for free. Thanks for pointing it out as I truly never'd of seen it.
Mike
  • Member since
    January 2005
  • From: Sweden
  • 38 posts
Posted by hubbabubba2 on Sunday, April 24, 2005 6:36 AM
Single-throw switches lets you toggle back and forth between the power packs, maybe god for the main line. Double-throw switches also lets you disconnect the track to park an engine or train, for example in a staging yard, while you keep on running two other trains.
Mattias
Moderator
  • Member since
    June 2003
  • From: Northeast OH
  • 17,249 posts
Posted by tstage on Sunday, April 24, 2005 7:28 AM
malexenko,

Welcome to the forum! [:)] Good to have you and your son aboard!

The Atlas book is a good one. It includes block wiring, switches, relays, reverse loops, and toggles, as well as an introduction to DCC (Atlas, of course). If you and your son ever think you may want to venture into DCC sometime down the line, I would encourage you to start wiring your layout with that thought in mind.

Again, malexenko, welcome to the forum!

Tom

https://tstage9.wixsite.com/nyc-modeling

Time...It marches on...without ever turning around to see if anyone is even keeping in step.

  • Member since
    April 2003
  • 305,205 posts
Posted by Anonymous on Sunday, April 24, 2005 11:46 AM
I'll look for the atlas book next time we are near a (good) train store. We understand the need to gap (we'll use the kato insulated connectors), but weren't clear about where we need/want to "block" or insulate things... like frog-to-frog connections, etc.

I also understand that power routing turnouts (the only choice in kato) complicates things.... so that's the sort of stuff we are looking for.

Regarding DCC, we will probably end up there "someday". If we wire with the common-rail (where we gap only one set of rails), will that work for DCC, or should we gap both sides for DCC?

Thanks to everyone, look forward to getting to know the site.

Subscriber & Member Login

Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!

Users Online

There are no community member online

Search the Community

ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter See all
Sign up for our FREE e-newsletter and get model railroad news in your inbox!