on Friday, November 19, 2004 3:05 PM
I am using MRC Tech 4 DC power packs and need to run multiple feeder wires to the tracks what is the best size wiring to use 18awg? What if it a longer run 10'+ use a higher gauge??
Reply
Edit
Anonymous
Member since
April 2003
305,205 posts
Posted by
Anonymous
on Friday, November 19, 2004 6:29 PM
I run 18 to 20 ga. feeder wires about every 4ft on my H.O. scale layout. Most are only about 2ft long or maybe in a tight area a little longer. I use solid wire because it's easier to solder. Then I use a 14 ga. stranded wire for the main feeders. All the feeders are soldered to the main. For years I only used the small ga. stuff for everything. Then I met a good electrician that rewired my layout from one end to the other. No more slow engines or flat spots.
Larry
Reply
Edit
mcouvillion
Member since
August 2003
From: Northeast Houston
576 posts
Posted by
mcouvillion
on Friday, November 19, 2004 10:31 PM
Buster1379,
Is your layout large or 4x8? 18 - 20 g wire is OK for a small layout, but for something larger, use at least 14 g wire (stranded) and drop short 20 g feeders from the rails to the larger bus wire. You should not have any appreciable voltage drop until you get 100' or so away from the power source. Use suitcase connectors for quick connections of the feeder wires to the bus wire.
Mark C.
Reply
Anonymous
Member since
April 2003
305,205 posts
Posted by
Anonymous
on Saturday, November 20, 2004 6:19 AM
Buster I am using the Tech 4 280 power pack by MRC. I have two main wires that run the entire length of my layout. They are 18ga wire, and I have wires 18ga solid wire running from them to the track every 2-3 feet and have no power supply problems. I can run the locomotives at a crawl or at high speed.
Reply
Edit
Subscriber & Member Login
Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!
Login
Register
Users Online
There are no community member online
Search the Community
ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter
See all
Sign up for our FREE e-newsletter
and get model railroad news in your inbox!
Sign up