Adding additional feeders - bus wiring & Cab Control
Posted by
Anonymous
on Monday, December 22, 2003 11:25 PM
I've learned that I need to add more feeders to each block in my switching layout. I have a sectional switching layout ( 6 "dominos" with a total of 8 blocks), wired for A&B Cab Control. I have two 6' dominos and a 4' domino making up 12 x 8 l-shape based on ATSF South Plains District (October/November/December 1996). I have only one pair of feeders per block, and I need to add more (2 more per 6' section and 1 per 4' section) since I'm getting a significant current power drop farther away from the control panel. I'd like to run a bus, and connect feeders to that. Currently both my S feeders run from DPDT toggle to S rail, and N returns go directly to terminal strip. How do I reconfigure to run a bus? Can I run a common bus and connect my S wires from the toggles to one common bus, or do I need a bus per block? My feeders are 16-gauge, and I'm planning to use a 12 gauge for the bus. I'm just not sure how to reconfigure the wiring. I don't want to run a mess of feeders from the terminal strip.
Reply
Edit
Anonymous
Member since
April 2003
305,205 posts
Posted by
Anonymous
on Tuesday, December 23, 2003 8:36 AM
southplains1:
Hello. I've used dual cab control with common-rail for a long time. I would like to help, but have a couple of questions for you:
a] What power packs are you using ? [ The amount of voltage drop on the size layout you describe sounds a bit odd, one doesn't usually encounter it unless you deal in distances over 60-75 feet. ]
b] I assume your dominos are to stay sectional [ movable ] in nature...how does the wiring go from one domino to the other right now ?
c] Within the confines of each domino, are all the track sections soldered together, or are some just kept together mechanically, with rail joiners ?
Merry Christmas and regards,
Mike
[:)]
Reply
Edit
Sperandeo
Member since
January 2001
From: US
1,300 posts
Posted by
Sperandeo
on Tuesday, December 23, 2003 9:05 AM
Hello "southplains1,"
Run one S-rail feeder from the control panel to each block, and then run a bus wire for each block from that first S-rail feeder to as many additional feeders as you need. A single 16-gauge bus wire should be adequate for all the common (N rail) feeders.
However, I think Mike has a point that the voltage drop you're seeing is unusual. I would suspect both the section connections between dominoes and the rail joiners, and I'd advise soldering all the uninsulated rail joints. (With dominoes you can adjust the fitters between sections to account for any expansion or rail creep.) If you can make the connections more solid, you probably won't need feeders or busses any heavier than you already have.
Happy holidays,
Andy
Andy Sperandeo MODEL RAILROADER Magazine
Reply
Anonymous
Member since
April 2003
305,205 posts
Posted by
Anonymous
on Tuesday, December 23, 2003 9:09 AM
Hello, Southplains!
I'm working on the same layout except I am using EasyDCC. I have had no such voltage drop problems. I would strongly urge you to consider DCC for a layout like this. It makes multioperator sessions sooooo much more enjoyalbe.
Ed
Reply
Edit
Subscriber & Member Login
Login, or register today to interact in our online community, comment on articles, receive our newsletter, manage your account online and more!
Login
Register
Users Online
There are no community member online
Search the Community
ADVERTISEMENT
ADVERTISEMENT
ADVERTISEMENT
Model Railroader Newsletter
See all
Sign up for our FREE e-newsletter
and get model railroad news in your inbox!
Sign up