Trains.com

Reversing Loop

2580 views
10 replies
1 rating 2 rating 3 rating 4 rating 5 rating
  • Member since
    December 2004
  • From: Winter Springs, FL
  • 123 posts
Reversing Loop
Posted by dukebasketballer` on Monday, June 20, 2005 4:29 PM
Hi,
I have a reversing loop planned for my new layout and I am planning to use LGB's reverse loop kit. But, this means that I will still have to manually switch the direction. Does any one have a solution or possibly even a better way to do a reverse loop without using LGB's kit?
Thanks for your time and Knoledge,
David
David Wenrich
  • Member since
    April 2003
  • 305,205 posts
Posted by Anonymous on Monday, June 20, 2005 8:47 PM
Since you are using track power, the only advice I could give you is to go DCC. Digitrax for instance, has a automatic reversing unit that is a hook it up and forget it deal. It does it's thing, and you run trains. No switches, nothing to fool with after it is hooked up.
  • Member since
    December 2004
  • From: Winter Springs, FL
  • 123 posts
Posted by dukebasketballer` on Tuesday, June 21, 2005 10:52 AM
Thanks,
I had thought about DCC before, but its a bit too costly for me since I'm doing this project off of allowence, but I'll probably wind up up with down the road.
Thanks,
David
David Wenrich
  • Member since
    April 2003
  • 305,205 posts
Posted by Anonymous on Thursday, June 23, 2005 4:06 PM
Another possiblity is don't have a reverse loop. Use a dogbone layout. Just a suggestion!
  • Member since
    April 2003
  • 305,205 posts
Posted by Anonymous on Thursday, June 23, 2005 6:34 PM
David,

If you want an automated LGB solution take a look at this PDF:

http://www.lgb.de/pdf/00559interim.pdf

Hmmm, can't seem to raise the LGB website. But that PDF does show how to wire up an automatic reversing loop. Too complicated for me but it should work.

Best,
TJ

  • Member since
    August 2004
  • From: North of Chicago
  • 1,050 posts
Posted by Tom The Brat on Friday, June 24, 2005 9:30 AM
For a simple, manual way to do it, see

http://www.gardentrack.com/Info/reverse.html
  • Member since
    December 2004
  • From: Winter Springs, FL
  • 123 posts
Posted by dukebasketballer` on Friday, June 24, 2005 7:01 PM
Thanks for your suggestions, I am going to use diagram on how to make an automated one.
Thanks for your time and knowledge,
Dukebasketballer
David Wenrich
  • Member since
    July 2003
  • From: usa
  • 15 posts
Posted by hobo on Friday, June 24, 2005 10:04 PM
Hi
Iv'e used track detectors from www.dallee.com
I had a single mainline with a reverse loop on each end.one detector would switch the turnouts,second detector would reverse polarity of main line.Give them a look,not to expensive. Good luck, Hobo
  • Member since
    April 2003
  • 305,205 posts
Posted by Anonymous on Sunday, June 26, 2005 8:19 AM
I recently ran across a site that a fellow had set up a reversing loop that didn't need to switch the points. It was set up for one direction only. He modified a turnout so you didn't have to throw it. I can't find the site now. Does anyone know the one I'm talking about?
He fixed the points in the siding direction, and then cut a gap so the train would go straight through when facing the points. The siding side could only be used to return to the straight part. Locos usually aren't a problem with forcing the switch over, but cars will commonly derail, because of lack of wieght, if the switch is not in the proper direction.
  • Member since
    April 2003
  • 305,205 posts
Posted by Anonymous on Sunday, June 26, 2005 7:53 PM
I think the original poster meant switching the loco direction, not the points of the turnout.

Whether you make the turnout one way or not, you do have to do something when you come out of the loop, since the track polarity must be reversed. You need a box that senses the short circuit when your loco straddles the two different polarities when emerging from the reversing loop.

In DCC, you would get a booster that auto-reverses when it senses a short.

By the way, DCC is not that expensive. When you start doing reversing loops, and separate the main line to separate blocks, all the extra electrical equipment starts to mount up. DCC is much easier to wire.

If you have only one loco at a time on the track, then DC with the associated electronics is cheaper.

To solve your problem in the most inexpensive way, you need to isolate the loop power from the main line. You also need to be able to reverse the main line polarity independently of the loop. If you always enter the loop from the same direction, then you might be able to save one DPDT switch, but why?

Set the loop polarity so that it matches the main line. Once you are in the loop, reverse the polarity on the main line, and when the train exits, it will keep running forward, rather than short out.

Regards, Greg
  • Member since
    July 2004
  • From: Spartanburg, SC
  • 1,503 posts
Posted by GP-9_Man11786 on Monday, June 27, 2005 5:55 PM
No wonder O-guage Hi-Rail is so popular.

Modeling the Pennsylvania Railroad in N Scale.

www.prr-nscale.blogspot.com 

Search the Community

FREE EMAIL NEWSLETTER

Get the Garden Railways newsletter delivered to your inbox twice a month

By signing up you may also receive occasional reader surveys and special offers from Garden Railways magazine. Please view our privacy policy