I don't know if many of you blokes know about my Golden Mountain train which is out of the same stable as the Orient Express
it is just three luxury LGB coaches pulled by my Mallet loco. Well Danny S had a day at his place over the weekend and we went down to Brisbane and participated; it was a good day and enjoyed by all.
But I had a small incident which I would not describe as a problem more the opposite.
My Mallet went round Danny's track really well doing all the tings it should do and making all the sounds it should make. But every circuit nearly it would stop in the same place go through its cycle of opening the firebox door, shoveling coal in, shutting the door and a quick whistle and it was off again.
For the last eighteen months it has been running on MTS and this is the first time it has run on normal DC for all that time. My problem is it has never done this before and i really do not know why it does it; as i would like it to do it more often.
Does anyone have any ideas why?
Rgds Ian
Reply
Edit
bman36
Member since
January 2014
1,264 posts
Posted by
bman36
on Monday, February 28, 2005 8:50 AM
Ian,
My guess is that the loco is factory set to do so on a continuous run when running on analog control. Neat feature. As for setting it to do so on DCC I have no idea. As you have mentioned in the past instructions are nearly non-existant. I will be curious to see how this works. Rgds eh...Brian.
Reply
Tom The Brat
Member since
August 2004
From: North of Chicago
1,050 posts
Posted by
Tom The Brat
on Monday, February 28, 2005 12:00 PM
You're saying that's a feature, not a bug?
Sorry, I've been in software for twentymumble years[C):-)]
Reply
Anonymous
Member since
April 2003
305,205 posts
Posted by
Anonymous
on Monday, February 28, 2005 12:37 PM
Are there any magnets on your friends track?Could be a magnet triggering something in the loco as it is at the same spot every time.
Troy
Reply
Edit
Chompers
Member since
April 2003
From: New York
214 posts
Posted by
Chompers
on Monday, February 28, 2005 3:44 PM
LGB has those Sound Magnets.
They activate the wistle/bell on my mogul.
The P.C.&.M.R.R SA#14
Reply
bobgrosh
Member since
April 2002
76 posts
Posted by
bobgrosh
on Monday, February 28, 2005 4:02 PM
Most likely a bad turnout or just a couple of bad rail joiners. DC is much less tolerant of dirty track than MTS. The lower voltage you were running at caused the processor on the MTS decoder to reset and therefore go through the startup routine.
It is possible to make the loco behave this way by creating a DC stopping section. You will have to isolate a few feet of track and apply 24 volts DC to it, Then you have to use a track sensor, and feedback interface to reconnect the stopping section to the DCC signal to restart the loco.
B0B
Reply
Search the Community
FREE EMAIL NEWSLETTER
Get the
Garden Railways
newsletter delivered to your inbox twice a month
Sign up
By signing up you may also receive occasional reader surveys and special offers from
Garden Railways
magazine. Please view our
privacy policy
More great sites from Kalmbach Media
Terms Of Use
|
Privacy Policy
|
Copyright Policy