Smoke unit service .
Posted by dougdagrump on Wednesday, June 1, 2005 8:43 PM
I just finished checking the smoke unit on my C-420, #412, with one more to go, #411. The funnel that runs between the body mounted stack and the the smoke unit is showing what appears to be the remains of some sort of gasket between the funnel and the body. The Lionel parts breakdowns don't show this gasket(?) anywhere. Anybody know anything about them or a possible substitute? [D)] [%-)] [sigh]
Forgot to say it was running bass ackwards.

Remember the Veterans. Past, present and future.

www.sd3r.org

Proud New Member Of The NRA

  • Member since
    February 2004
  • From: Rolesville, NC
  • 15,416 posts
Posted by ChiefEagles on Thursday, June 2, 2005 8:33 AM
Doug, if you need a sub, try plumbers string packing or a Ace Hardware gromet. I almost know all of my SD80's are running backward compared to the SD60 [that smokes up a storm]. Also going to check the speakers, the SD80's are half the volume of the SD60. Been reminded tha the speaker wires can be reversed on Lionels.

MAN, you're up early in CAL. !!!!!

 God bless TCA 05-58541   Benefactor Member of the NRA,  Member of the American Legion,   Retired Boss Hog of Roseyville Laugh,   KC&D QualifiedCowboy       

              

  • Member since
    February 2004
  • From: Rolesville, NC
  • 15,416 posts
Posted by ChiefEagles on Thursday, June 2, 2005 1:26 PM
Just took the top of of one of my SD80's and the wick looks might brown. [:(]

 God bless TCA 05-58541   Benefactor Member of the NRA,  Member of the American Legion,   Retired Boss Hog of Roseyville Laugh,   KC&D QualifiedCowboy       

              

  • Member since
    February 2004
  • From: Rolesville, NC
  • 15,416 posts
Posted by ChiefEagles on Thursday, June 2, 2005 6:39 PM
Just got the word [from a YANKEE train repairman] on wicks and the sleves or socks over elements. You can use "MR. PINK" [fiberglass insulation] as replacement. Also, take the sleve or sock off of the element, make a string of the pink insulation, wrap around the element, soak it in smoke fluid, put it back together, fill her up with fluid and away it smokes.

 God bless TCA 05-58541   Benefactor Member of the NRA,  Member of the American Legion,   Retired Boss Hog of Roseyville Laugh,   KC&D QualifiedCowboy       

              

  • Member since
    April 2003
  • From: Pittsburgh, PA
  • 1,429 posts
Posted by MartyE on Thursday, June 2, 2005 6:57 PM
I've been doing the pink fiberglass deal ever since Norm C from the OGR forum suggested it. He has a pretty good tips page for it @ http://norm.beesky.com/smoke.html . The reverse fan rotation though is a new one. I improved my SD40 with it and I did the Norm C trick for my LM T-1. Next up is to check the fan rotation on the T-1. If it is backwards this baby will fill the room when I fix it. Thanks again *** Teal!

Trying to update my avatar since 2020 Laugh

MartyE and Kodi the Husky Dog! ( 3/31/90-9/28/04 ) www.MartyE.com My O Gauge Web Page and Home of Kodiak Junction!

  • Member since
    December 2001
  • From: Austin, TX
  • 10,096 posts
Posted by lionelsoni on Friday, June 3, 2005 7:56 AM
Speaker wires, Frank?

Bob Nelson

  • Member since
    April 2003
  • From: Pittsburgh, PA
  • 1,429 posts
Posted by MartyE on Friday, June 3, 2005 9:40 AM
Yes on some of the Lionels with dual speakers, one of them could have been wired out of phase causing lower volume.

The wires should form an X like the picture below...


If they just go straight across they are out of phase.

Trying to update my avatar since 2020 Laugh

MartyE and Kodi the Husky Dog! ( 3/31/90-9/28/04 ) www.MartyE.com My O Gauge Web Page and Home of Kodiak Junction!

  • Member since
    December 2001
  • From: Austin, TX
  • 10,096 posts
Posted by lionelsoni on Friday, June 3, 2005 10:16 AM
I see. I didn't know that anyone was using dual speakers.

Bob Nelson

  • Member since
    July 2003
  • From: North Texas
  • 5,707 posts
Posted by wrmcclellan on Friday, June 3, 2005 11:16 AM
Bob,

Glad you asked as that one was puzzling me also!

Regards,
Roy

Regards, Roy

  • Member since
    April 2003
  • 305,205 posts
Posted by Anonymous on Friday, June 3, 2005 1:18 PM
My plymoth was drowned with smoke fluid how am I going to repair it?:(
  • Member since
    February 2004
  • From: Rolesville, NC
  • 15,416 posts
Posted by ChiefEagles on Friday, June 3, 2005 7:24 PM
Marty, thanks. Knew that but did not know how to tell if they were wrong. Tried the string of fiberglass wrap around the element. Works but Buckeye said just take it off completely. So I did. Well, used pink fiberglass for wick and made sure the element was pressing against it. Smokes like a MTH. As Buckeye pointed out, if the pink fiberglass insulation chars, how much does it cost to replace??? [;)] So, take the smoke unit apart, remove the sleve/sock over the element and replace the wick with pink insulation. Give her a wetting with smoke fluid and away she will go. Now if you get too much fluid, I blow down the stack [don't get too close or you will get a mouth full of fluid]. It will blow back out until you can get the remainder hot enough to evaporate like normal.

 God bless TCA 05-58541   Benefactor Member of the NRA,  Member of the American Legion,   Retired Boss Hog of Roseyville Laugh,   KC&D QualifiedCowboy       

              

  • Member since
    November 2003
  • From: Sandy Eggo
  • 5,608 posts
Posted by dougdagrump on Friday, June 3, 2005 8:51 PM
Hmmmmm, I guess now I'll have to go scrounging at some building sites for some left over "Pink Insulation" scraps .[:D]

Remember the Veterans. Past, present and future.

www.sd3r.org

Proud New Member Of The NRA

  • Member since
    March 2004
  • From: Over the Rainbow!
  • 760 posts
Posted by eZAK on Sunday, June 5, 2005 9:50 AM
alexbutner,

Let the plymoth sit upside down on a towel for several hours or over night.
Then remove the shell and dry up any areas with Q'tips and a rag.
Relax, Don't Worry, Have a Home Brew!</font id="size2"> Pat Zak</font id="size3">
  • Member since
    January 2005
  • From: New England
  • 6,241 posts
Posted by Jumijo on Monday, June 6, 2005 5:33 AM
QUOTE: Originally posted by ChiefEagles

Marty, thanks. Knew that but did not know how to tell if they were wrong. Tried the string of fiberglass wrap around the element. Works but Buckeye said just take it off completely. So I did. Well, used pink fiberglass for wick and made sure the element was pressing against it. Smokes like a MTH. As Buckeye pointed out, if the pink fiberglass insulation chars, how much does it cost to replace??? [;)] So, take the smoke unit apart, remove the sleve/sock over the element and replace the wick with pink insulation. Give her a wetting with smoke fluid and away she will go. Now if you get too much fluid, I blow down the stack [don't get too close or you will get a mouth full of fluid]. It will blow back out until you can get the remainder hot enough to evaporate like normal.


Does removing the sleeve/sock from around the heating element cuase any future problems, like overheating or element burnout?

Jim

Modeling the Baltimore waterfront in HO scale

  • Member since
    April 2003
  • From: Pittsburgh, PA
  • 1,429 posts
Posted by MartyE on Monday, June 6, 2005 6:34 AM
QUOTE: Does removing the sleeve/sock from around the heating element cuase any future problems, like overheating or element burnout?


I have had the ones I serviced off for more than a couple of years with no issues.

Trying to update my avatar since 2020 Laugh

MartyE and Kodi the Husky Dog! ( 3/31/90-9/28/04 ) www.MartyE.com My O Gauge Web Page and Home of Kodiak Junction!

  • Member since
    February 2004
  • From: Rolesville, NC
  • 15,416 posts
Posted by ChiefEagles on Monday, June 6, 2005 6:34 AM
Not if you keep the fluid in the wick. Just seems to let the element give off smoke better than when covered. You get some charring anyway with the Lionel wick and sleeve. Now you just chunk the pink fiberglass wick and replace it with more. It does seem that you need to add more fluid to keep the pink wet. The old Lionel wick does not hold as much fluid as the pink will. But adding more fluid makes sense. You are evaporating more due to more smoke being produced. Check Marty's link to Beesky. He says chunk the sleeve. Try one for a while and see.

 God bless TCA 05-58541   Benefactor Member of the NRA,  Member of the American Legion,   Retired Boss Hog of Roseyville Laugh,   KC&D QualifiedCowboy       

              

  • Member since
    April 2003
  • From: Pittsburgh, PA
  • 1,429 posts
Posted by MartyE on Monday, June 6, 2005 7:25 AM
Here is the link to Norm Charbonneau's smoke unit tip page again. Bookmark it as it is really useful. As a matter of fact his whole site is something to see. Norm C is pretty much an artist when it comes to layouts.

http://norm.beesky.com/smoke.html

Trying to update my avatar since 2020 Laugh

MartyE and Kodi the Husky Dog! ( 3/31/90-9/28/04 ) www.MartyE.com My O Gauge Web Page and Home of Kodiak Junction!

  • Member since
    December 2003
  • From: Baltimore, MD, USA
  • 263 posts
Posted by 4kitties on Tuesday, June 21, 2005 11:00 AM
Has anyone published a list of Lionel engines affected by the smoke unit fan being wired backwards? I did a forum search and came up empty. I'm wondering about my PRR J-1a and my JLC N&W Y6b. Frankly, I don't even know if either or both of these have a fan-driven smoke unit.