Trains.com

Lionel V & Z Trainmaster Transformers

1463 views
9 replies
1 rating 2 rating 3 rating 4 rating 5 rating
  • Member since
    November 2022
  • 7 posts
Lionel V & Z Trainmaster Transformers
Posted by HankS on Friday, March 24, 2023 4:26 PM

Hello,

Does anyone know what size AWG wire is used for the A, B , C, & D post leads?

Seems like 16 AWG, but may be 14 AWG. Thans much, Hank S

 

  • Member since
    March 2010
  • 266 posts
Posted by rrlineman on Thursday, March 30, 2023 8:40 AM

Are you talking inside wire for repair or from the post to the track ?? If its for the outside, 16 gage is fine for a small layout. if you have a bigger layout then a 4x8 board with lots of track then I would use 14 gage as the main feeders and then 16 gage tapped off the 14 gage for the extra lockons on the layout. Inside is a different story.

  • Member since
    December 2001
  • From: Austin, TX
  • 10,096 posts
Posted by lionelsoni on Thursday, March 30, 2023 10:11 AM

The overriding consideration should be safety.  The V's overcurrent protection (an internal circuit breaker) is intended for 8 amperes, so the minimum external wire gauge should be 18 AWG, which has about that ampacity.  The Z can put out 14 amperes; so 14 AWG, whose ampacity is 15 amperes, should be used as a minimum with it.

If you don't need a transformer's full output for any one load, you can put lower-rated circuit breakers between the transformer and smaller, subdivided loads to reduce the wire ampacity needed for safety downstream of the transformer.

Bob Nelson

  • Member since
    November 2022
  • 7 posts
Posted by HankS on Thursday, March 30, 2023 12:15 PM

For Inside repair or replacement.

  Thanks You for your response!

  • Member since
    November 2022
  • 7 posts
Posted by HankS on Thursday, March 30, 2023 12:20 PM

Thanks for your reply, I was planning on using 16 AWG Silicon in V's ans 14 AWG Silicone in Z's. I have added an 8 amp breaker in V and 15 amp breaker in Z. Does this sound reasonable?

  Thanks again for you information!!

 

  • Member since
    November 2022
  • 7 posts
Posted by HankS on Thursday, March 30, 2023 12:23 PM

I re read your reply; I am refering to the internal wire of transformer. The short 5" or so runs inside.

Thanks again

  • Member since
    July 2020
  • 1,631 posts
Posted by pennytrains on Thursday, March 30, 2023 4:51 PM

I always go for a surplus of capacity.

Big Smile  Same me, different spelling!  Big Smile

  • Member since
    December 2001
  • From: Austin, TX
  • 10,096 posts
Posted by lionelsoni on Friday, March 31, 2023 3:25 PM

There should be no need to "add" 8-ampere and 15-ampere circuit breakers.  These are already present inside the transformer cases.  

Bob Nelson

Bob Nelson

  • Member since
    November 2022
  • 7 posts
Posted by HankS on Friday, March 31, 2023 4:11 PM

Thanks again; I am replaceing original breakers with modern breakers.

 I still need an answer to the INTERNAL wire gauge sizes, ie: connections from copper disc's to output posts for V and Z. Is 16 AWG good in the V and 14 AWG good in the Z, OR is 16 AWG good inside of both? I am going to use Silicone wire as I already have it.

    Thanks for your help

  • Member since
    December 2001
  • From: Austin, TX
  • 10,096 posts
Posted by lionelsoni on Friday, March 31, 2023 7:04 PM

With an ampacity of about 10 amperes, 16 AWG is a little too small for the Z, which can deliver 14 amperes.  On the other hand, it is a little larger than needed for the V, which can deliver 8 amperes.

I would select the "inside" and "outside" wire gauges by the same principles, whether or not that matched Lionel's wiring practices.

Bob Nelson

Join our Community!

Our community is FREE to join. To participate you must either login or register for an account.

Search the Community

FREE EMAIL NEWSLETTER

Get the Classic Toy Trains newsletter delivered to your inbox twice a month