Trains.com

91 Circuit Breaker!!

20411 views
36 replies
1 rating 2 rating 3 rating 4 rating 5 rating
  • Member since
    January 2010
  • From: Penndel, Pa.
  • 22 posts
Posted by davidam on Tuesday, March 30, 2010 7:08 PM

Bob Nelson

Could you recomend what type of transient voltage superssor should be used for kw's & type v transformers. I have experienced a melt down  of an electronic engine running on the  V transformer. By the way I am  not good with electronics. I wolud appreciate any advice you can give. Thanks

Dave Marconi

 

 

  • Member since
    December 2001
  • From: Austin, TX
  • 10,096 posts
Posted by lionelsoni on Wednesday, March 31, 2010 5:27 PM

Vishay 1.5KE36CA.  Wire it across (in parallel with) the track.  It is a bidirectional unit, so polarity doesn't matter.

Bob Nelson

  • Member since
    December 2010
  • 36 posts
Posted by jsonova99 on Sunday, October 23, 2011 8:15 AM

I was planning on wiring TVS diodes right across the terminals on the transformer (ZW & 1033), at least until I have a more permanent setup.

  • Member since
    February 2007
  • 928 posts
Posted by bfskinner on Monday, February 11, 2013 4:28 PM

Request for update from Bob "lionelsoni" Nelson

Bob, if I am reading the current Mouser catalog correctly (as of Feb 2013) this part is not available -- which is not quite the same thing as saying they cannot supply a substitute.. Could you recommend a suitable  substiture, and perhaps re-explain what the various essential terms of the part number mean (such as the code that specifies bi-directional)  and the voltage values within which the device will function properly in toy train applications?

Any help you can give that will make it easier for a layman to locate and acquire an appropriate TVS diode will be greatly appreciated. Thanks in advance.

bf
  • Member since
    December 2001
  • From: Austin, TX
  • 10,096 posts
Posted by lionelsoni on Monday, February 11, 2013 7:24 PM

Here is a link:

http://www.mouser.com/Circuit-Protection/TVS-Diodes-Transient-Voltage-Suppressors/_/N-5g3gZscv7?P=1yzv44x&Keyword=1.5KE36CA&FS=True

The "1.5" is the peak power rating in kilowatts.  The "36" is the nominal peak voltage.  The "CA" means "bidirectional".  "A" alone means unidirectional; but you don't want that.  There are three voltage ratings to consider:

Operating voltage--30.8 volts.  This should be no less than the RMS voltage times the square-root of 2, which is 29.7 for 21 volts RMS (ZW).

Breakdown voltage--34.2 volts.  This is the voltage at which the TVS will begin to conduct.

Peak voltage--49.9 volts.  This is the voltage to which the TVS will limit the circuit.

Bob Nelson

  • Member since
    February 2007
  • 928 posts
Posted by bfskinner on Monday, February 11, 2013 8:35 PM

Thank you, Bob

 

That was exactly what I was looking for. Don't know why I couldn't find it in the Mouser website except that they have a lot of very similarly-labled items and I guess my bifocals just weren't up to it.

bf
  • Member since
    April 2019
  • 1 posts
Posted by BayWindow on Tuesday, April 30, 2019 10:04 PM
The original prewar and the first postwar which except for high and low connections looks like the prewar is a magnetic breaker and VERY fast.

Join our Community!

Our community is FREE to join. To participate you must either login or register for an account.

Search the Community

FREE EMAIL NEWSLETTER

Get the Classic Toy Trains newsletter delivered to your inbox twice a month